Heat & Glo LifeStyle 6000G-LP, 6000G-IPILP owner manual Table of Contents

Page 3

Table of Contents

1 Listing and Code Approvals

A. Appliance Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. Glass Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 C. BTU Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . . 4 E. Non-Combustible Materials Specification. . . . . . . . . . . . . . 4 F. Combustible Materials Specification . . . . . . . . . . . . . . . . . 4 G. Electrical Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 H. Requirements for the Commonwealth of Massachusetts. . 5

2 Getting Started

A. Design and Installation Considerations . . . . . . . . . . . . . . . 6

B. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . . . . 6

C. Inspect Appliance and Components. . . . . . . . . . . . . . . . . . 6

3 Framing and Clearances

A. Selecting Appliance Location . . . . . . . . . . . . . . . . . . . . . . . 7

B. Constructing the Appliance Chase . . . . . . . . . . . . . . . . . . . 8

C. Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

D. Mantel Projections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

4 Termination Locations

A. Vent Termination Minimum Clearances . . . . . . . . . . . . . . 10

5 Vent Information and Diagrams

A. Vent Table Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

B. Use of Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

C. Measuring Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

6 Vent Clearances and Framing

A. Pipe Clearances to Combustibles . . . . . . . . . . . . . . . . . . 22 B. Wall Penetration Framing. . . . . . . . . . . . . . . . . . . . . . . . . 22 C. Vertical Penetration Framing . . . . . . . . . . . . . . . . . . . . . . 23 D. Install Attic Insulation Shield. . . . . . . . . . . . . . . . . . . . . . . 24

9 Gas Information

A. Fuel Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

B. Gas Pressures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

C. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

10 Electrical Information

A. Recommendation for Wire . . . . . . . . . . . . . . . . . . . . . . . . 38 B. Connecting to the Appliance. . . . . . . . . . . . . . . . . . . . . . . 38 C. Intellifire Ignition System Wiring . . . . . . . . . . . . . . . . . . . . 38 D. Standing Pilot Ignition System Wiring . . . . . . . . . . . . . . . 39 E. Junction Box Installation. . . . . . . . . . . . . . . . . . . . . . . . . . 40 F. Wall Switch Installation for Fan (Optional) . . . . . . . . . . . . 40

11 Finishing

A. Mantel Projections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

B. Facing Material. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

C. Finishing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

12 Appliance Setup

A. Remove Shipping Materials . . . . . . . . . . . . . . . . . . . . . . . 43

B. Clean the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

C. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

D. Ember Placement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

E. Positioning the Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

F. Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

G. Screen Mesh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

H. Grilles and Trim . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

I. Air Shutter Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

13 Operating Instructions

A. Before Lighting Appliance. . . . . . . . . . . . . . . . . . . . . . . . . 47 B. Lighting Instructions (IPI) . . . . . . . . . . . . . . . . . . . . . . . . . 48 C. After Appliance is Lit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 D. Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . 50

7 Appliance Preparation

A. Top Vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

B. Installing the Non-combustible Board. . . . . . . . . . . . . . . . 26

C. Securing and Leveling the Appliance . . . . . . . . . . . . . . . . 26

D. Install the Optional HEAT-ZONE-GAS Kit . . . . . . . . . . . . 27

8 Installing Vent Pipe (DVP and SLP Pipe)

A. Assemble Vent Sections (DVP Pipe Only) . . . . . . . . . . . . 28 B. Assemble Vent Sections (SLP Pipe Only) . . . . . . . . . . . . 29 C. Assemble Slip Sections . . . . . . . . . . . . . . . . . . . . . . . . . . 29 D. Secure the Vent Sections. . . . . . . . . . . . . . . . . . . . . . . . . 30 E. Disassemble Vent Sections . . . . . . . . . . . . . . . . . . . . . . . 30 F. Install Decorative Ceiling Components (SLP only). . . . . . 31 G. Install Metal Roof Flashing . . . . . . . . . . . . . . . . . . . . . . . . 32 H. Assemble and Install Storm Collar . . . . . . . . . . . . . . . . . . 32 I. Install RF4-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 J. Install Vertical Termination Cap . . . . . . . . . . . . . . . . . . . . 34 K. Install Decorative Wall Components (SLP only). . . . . . . . 34 L. Heat Shield Requirements for Horizontal Termination . . . 34 M. Install Horizontal Termination Cap (DVP and SLP Pipe) . 35

14 Troubleshooting

A. Standing Pilot Ignition System . . . . . . . . . . . . . . . . . . . . . 51 B. Intellifire Ignition System . . . . . . . . . . . . . . . . . . . . . . . . . 53

15 Maintaining and Servicing Appliance

A. Maintenance Tasks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

16 Reference Materials

A. Appliance Dimension Diagram. . . . . . . . . . . . . . . . . . . . . 57

B. Vent Components Diagrams . . . . . . . . . . . . . . . . . . . . . . 58

C. Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

D. Limited Lifetime Warranty. . . . . . . . . . . . . . . . . . . . . . . . . 69

E. Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

= Contains updated information.

Heat & Glo • 6000G, 6000G-IPI2103-900 Rev. M • 9/08

3

Image 3
Contents Hot glass will cause burns What to do if you smell gasHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsInstallation to ensure maximum safety and benefit Getting StartedTools and Supplies Needed Selecting Appliance Location Framing and ClearancesConstructing the Appliance Chase ClearancesClearance to Combustibles To Ceiling Mantel ProjectionsTermination Locations Vent Termination Minimum ClearancesSee .4 for specific clearances Alcove Applications Measuring Standards Vent Information and DiagramsVent Table Key Use of ElbowsV1 Minimum H1 + H2 Maximum Vent DiagramsTop Vent Horizontal Termination One Elbow Minimum MaximumMin Max V2 Min H2 Max Top Vent Horizontal Termination Three ElbowsE a K R E Flue Restrictor InstructionsMaximum + V 2 Min H1+ H2 V1 + V2 Minimum H1+ H2 Maximum Top Vent Vertical TerminationH1 = 16 in mm Maximum Rear Vent Horizontal TerminationH1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Max H1 Maximum V1 Minimum H1+ H2 MaximumH1+ H2 Maximum V1 Minimum Rear Vent Vertical TerminationV1 Minimum H1+ H2+ H3 Maximum 10 ft Maximum Minimum + H 2 MaximumCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingPipe DVP SLP Vertical Penetration FramingInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Appliance Preparation Top VentProceed to . C Securing and Leveling the Appliance Installing the Non-combustible BoardInstall the Optional HEAT-ZONE-GAS Kit Assemble Pipe Sections DVP Pipe Only Installing Vent Pipe DVP and SLP PipeAttach Vent to the Firebox Assembly Assemble Vent Sections DVP Pipe OnlyAssemble Slip Sections Assemble Vent Sections SLP Pipe OnlyDisassemble Vent Sections Secure the Vent SectionsInstall Decorative Ceiling Components SLP only Assemble and Install Storm Collar Install Metal Roof FlashingSLP-FS Install RF4-8Install Vertical Termination Cap Install Decorative Wall Components SLP onlyHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap DVP and SLP Pipe Ansi Z223.1 and CAN/CGA-B149 installation codesRefer to of this manual Pressure Natural Gas Propane Gas InformationFuel Conversions Gas Connection Gas PressuresHigh Altitude Installations Optional Accessories Requirements Recommendation for WireIntellifire Ignition System Wiring Connecting to the ApplianceIntellifire Pilot Ignition IPI Wiring Diagram Standing Pilot Ignition System WiringJunction Box Installation Wall Switch Installation for Fan OptionalVAC to wall switch Facing Material FinishingFinish Door FIT Material See Maximum Thickness Finishing MaterialEmber Placement Appliance SetupClean the Appliance AccessoriesLog #1 SRV2103-107 Positioning the Logs12 Front View Grilles and Trim Glass AssemblyAir Shutter Setting Screen MeshBefore Lighting Appliance Operating InstructionsTurn off all electric power to the appliance Lighting Instructions IPIFinal inspection by Standing Pilot Ignition For Your Safety Read Before Lighting Lighting InstructionsFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System flame has been lit, flame Maintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksAppliance Dimension Diagram Reference MaterialsLocation Inches Millimeters P 4 5 4 5 E lb o w Vent Components DiagramsDVP vent components Horizontal Termination Cap13-3/4 13-7/8 352 mm 349 mm 787 mm 13-1/4 367 mm 24-5/8 625 mm 27-1/2Roof Flashing Multi-pak 13-3/4 11-7/8 349 mm 302 mmDVP-TVHW DVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP Roof Flashing Ceiling Firestop Support ElbowWall Shield Firestop RF4-8Adapter SnorkelSupport Box-Black PVK-80Log Set Assembly Service PartsPart number list on following IPI Ignition Service Parts List 6000G, 6000G-IPIAt Depot Standing PilotStocked Standing Pilot Valve Assembly6000G-IPI IPI Valve AssemblyCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

6000G-IPILP, 6000G-IPI, 6000G, 6000G-LP specifications

The Heat & Glo LifeStyle 6000 series offers a sophisticated solution for homeowners seeking both performance and style in their heating options. With models such as the 6000G, 6000G-IPILP, 6000G-IPI, and 6000G-LP, this series combines innovative technologies with elegant design, making it a preferred choice for many.

One of the standout features of the LifeStyle 6000 series is its advanced heating technology. The units utilize Direct Vent technology, which ensures efficient combustion by drawing air from the outside for combustion and venting exhaust air outdoors. This not only enhances efficiency but also maintains a safe and comfortable indoor environment. Additionally, these models are designed with advanced burner systems that provide realistic flame effects and a warm ambiance, making them perfect for any living space.

The aesthetic appeal of the LifeStyle 6000 series cannot be overlooked. These fireplaces boast a contemporary design that seamlessly integrates into various architectural styles. With customizable options like different front styles and finishes, homeowners can truly make the fireplace their own. The impressive viewing area, thanks to large glass doors, amplifies the beauty of the flames while also allowing for maximum heat output.

Thermal efficiency is a key characteristic of the LifeStyle 6000 series. With an impressive heating capacity, these units can effectively warm large spaces. Furthermore, they feature a range of BTU outputs, allowing users to select the model that best suits their heating needs. Models equipped with the IntelliFire Ignition system further enhance usability, providing reliable startup with the convenience of remote control operation.

Safety is also paramount in the design of the LifeStyle 6000 series. Each model comes with built-in safety features such as a glass safety barrier and optional automatic shut-off systems, ensuring peace of mind for users.

In summary, the Heat & Glo LifeStyle 6000 series, including the 6000G, 6000G-IPILP, 6000G-IPI, and 6000G-LP, stands out in the market for its combination of modern aesthetics, innovative heating technologies, and robust safety features. Whether enhancing a cozy living room or providing warmth in a spacious area, these fireplaces offer a stylish and efficient heating solution for contemporary homes.