Harman Stove Company 1-90-797000 manual Oakleaf Woodburning Stove

Page 27

Oakleaf Woodburning Stove

Providing you have the charcoal bed described, close the bypass damper by pulling the handle toward the front of the stove. This will begin the highly efficient mode of operation where the exhaust gases get re-burned in the secondary combustion package. If you cannot achieve a charcoal bed within the first 15 to 20 minutes, your wood is likely too wet, and you may need to burn the fire longer and/or hotter to compensate for the extra energy needed to drive out the moisture. If, after five minutes of burning with the damper closed, smoke is visible coming from the chimney, you probably do not have the proper coal bed. Open the bypass damper and continue with the process until a significant coal bed is formed.

Always remember to open the bypass damper when you are loading, this allows the exhaust gases to pass directly into the flue outlet and reduces the chance of smoke spillage into the room.

Reloading: Once you have prepared and maintained a thick charcoal bed, and the secondary combustion is established, you should be able to reload the stove at any time by simply opening the bypass damper, then the load door, adding fuel and closing the door then the damper. This depends on coal bed size, load size and moisture content of fuel.

Removing Ashes: Before reloading, empty the ash pan (remember to close the ash door while emptying the pan). The ashes should be the coolest at this time. Remove ashes from the fire chamber periodically by raking a poker across the bottom grates.

Excessive ash buildup can prevent proper venting of exhaust gases. Do not allow the ash pan to over-fill. Ash buildup between the ash pan and the bottom of the grate can cause the grate to overheat and wear out prematurely.

The Oakleaf is designed to provide access to the ash pan without the need for opening the main door.

Before opening the ash door and removing the ash pan, open the by- pass damper. Wearing

heavy protective gloves,

open the ash door and

remove the ash pan by

pulling it forward by the

handle. Close the ash

door and damper by-

pass before taking the ashes outside for safe disposal.

Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible materi- als, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled.

Never use the ash disposal container for other trash. Wood ash can be added to your garden or compost.

CAUTION

The stove is hot while in operation. Keep chil- dren, clothing and furniture away. Contact may cause skin burns.

Never leave the stove unattended if either the ash or load door is open. Overfiring may result.

Risk of Excessive Temperatures. Keep Ash Door Closed During Firing of the Heater.

Avoid overfiring your stove. Overfiring is a poten- tially hazardous situation which can lead to overheat- ing of combustible materials nearby, damage to the stove, and in extreme cases, cause a fire. Overfiring is caused by: 1. Too much air flowing through the stove too quickly. 2. You may have positioned the primary air control lever too far to the right. 3. Inadvertently leaving the damper open or 4. Not keeping up with routine maintenance, such as checking door gaskets for wear.

Overfiring results in excessive fuel consumption, and may cause parts of the stove or chimney connec- tor to glow red. If you notice signs of overfiring, reduce the air supply to the fire, and review the Maintenance section in this manual.

In the event of a chimney fire, call your local fire department; make sure everyone is safely out of the house. Reduce the air intake of the stove as much as possible using the air control lever; close the bypass damper to further restrict air flow. Do not throw water on the fire; this can cause stove damage and create an even more dangerous situation. Have your chimney professionally cleaned and inspected before resuming burning in your stove.

As you begin to operate your stove at higher temperatures, you will notice a “hot” or unpleasant smell; this is just the paint going through the curing process, and will disappear after a few fires.

Save These Instructions

3-90-798

Dry Seasoned Wood Only!

27

Image 27
Contents Model Installation and OperationOakleaf Woodburning Stove Table of Contents This appliance is also approved for installation in a shop 1Listing and Code ApprovalsMobile Home Approved 2Special Warnings and Notes If the alarm soundsAppliance Location Design, Installation & Location ConsiderationsFire Safety 3Getting StartedFlue Direction Conversion Component LocationsFire Risk Pre- Use Check ListAppliance Dimensions 4Dimensions & Clearances17 / 432 mm 14 / 356 mm 26.75 / 679 mm *17.5 / 444 mm Clearances To CombustiblesClearance to Combustibles Floor Protection Requirements Floor Protection RequirementsFloor Protection RequirementsWall Pass-thrus Chimney ConnectorsChimneys and Venting DraftChimney AN Approved Canadian Wall PASS-THROUGHVenting to a Masonry Fireplace Chimney Installing to a Prefabricated ChimneyExisting Masonry Chimneys Venting to a Masonry ChimneyChimney Cap Storm Collar Sections Roof Flashing Airtight insulated Clean-out Stainless Steel Chimney Connector Must Extend to Flue Liner Full Relining Fireplace Conversion Freestanding Appliance Chimney Breach Fireplace Conversion with Combustible Wall 6Mobile Home Mobile Home InstallationAppliance Set-Up Outside Air Attachment Leveling the ApplianceOptional Cooking Grill Optional Blower Installation Optional Rear-vent Rear ShieldOptional Bottom Heat Shield General Operating Information Fuel SpecificationsAlways wear fire retardant Gloves when operating the stove 8Operating InstructionsGrates Or change the configuration of this grate systemCombustion Process DoorsUser Controls Before Your First FireBuilding and Maintaining a Fire Oakleaf Woodburning Stove 9Service & Maintenance Seasonal cleaningCreosote- Formation and Need For Removal Door Glass General Maintenance ProceduresAsh Removal By User Wear Leather Gloves To Prevent Skin BurnsChimney Chimney ConnectorBlower- If installed Firebox10Reference Materials Oakleaf Optional Blower Kit #1-00-797032 Wiring DiagramOakleaf Service PartsAt depot StockedStocked at depot 50% 60% 70% 80% 90% 100% Grams Per HourHearth & Home Technologies Inc Limited Lifetime WarrantyThis warranty is void if Warranty ConditionsService & Maintenance Log Page Proudly Printed On 100% Recycled Paper