Harman Stove Company 1-90-797000 manual Oakleaf Woodburning Stove

Page 2
Save These Instructions

Oakleaf Woodburning Stove

Hearth & Home Technologies welcomes you to our tradition of excellence! By choosing a Harman appliance, you have become part of our commitment to meeting the heating needs of consumers with the most distinctive, powerful and responsible home heating products available.

The Oakleaf has huge features in an elegantly small package. With a heating capacity of 1400 to 1600 ft², The Oakleaf takes advantage of Harman’s 30+ years of stove design, technology and manufacturing. The Firedome secondary combustion system provides for super-clean burning and minimal maintenance. The top-loading feature makes for more convenient loading, with enough fuel for an all day burn.

We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance.

Thank you for choosing Harman.

Harman, A division of

Hearth & Home Technologies, Inc.

352 Mountain House Road

Halifax, PA 17032

www.harmanstoves.com

When This Room Heater Is Not Properly Installed, a House Fire May Result.

To Reduce The Risk Of Fire, Follow The Installation Instructions. Contact Local Building Or Fire Officials About Restrictions And Installation Inspection Requirements In Your Area.

This Label is located on the rear of the appliance. It contains important safety test information as well as the clearances to combustible materials. The label also contains the appliance serial number. For your records, copy your serial number and purchase date here.

Serial #: ________________________

Date of Purchase: ________________________

OAKLEAF Woodburning Stove

Poêle Du Bois OAKLEAF

Serial No. 008 № de série

Report #/ Raport # 135-S-26-6.2

Tested to / Testé à: UL1482-10, and ULC S627-00

Test Date: August 2010

Approved For Use in Mobile/Manufactured Homes- USA ONLY

This appliance is also approved for installation into a shop.

“PREVENT HOUSE FIRES”

Install and use only in accordance with manufacturer’s installation and operation instructions and local codes. In absence of local codes, installation must meet minimum requirements of NFPA 211 in USA. Refer to manufacturer’s instructions and local codes for precautions required

Rapport no 135-S-26-6.2

Conforme à UL 1482-10 et ULC S627-00

Date d’essai: Aug. 2010

Homologué pour les maisons mobiles et préfabriquées - É.-U. SEULEMENT Cet appareil est également homologué pour être installé dans un atelier.

«ÉVITEZ LES INCENDIES DE MAISON»

N’installez et n’utilisez cet appareil que selon le mode d’installation et le mode d’emploi du fabricant et les codes locaux. En l’absence de codes locaux,

CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS.

SEE NAMEPLATE AND INSTRUCTIONS. KEEP FURNISHINGS AND OTHER COMbUSTIbLE MATERIALS A CONSIDERAbLE DISTANCE AWAY FROM THIS APPLIANCE.

ATTENTION:CHAUD LORS DU FONCTIONNEMENT. NE TOUCHEZ PAS L’APPAREIL.GARDEZ LES ENFANTS ET LES VÊTEMENTS ÉLOIGNÉS. TOUT CONTACT PEUT ENTRAÎNER DES BRÛLURES DE LA PEAU. RÉFÉREZ-VOUS À LA PLAQUE SIGNALÉTIQUE ET AU MODE D’EMPLOI. GARDEZ LE MOBILIER ET LES AUTRES MATÉRIAUX COMBUSTIBLES BIEN À L’ÉCART DE L’APPAREIL.

for passing chimney through a combustible wall or ceiling.

WARNING FOR MANUFACTURED HOMES: (US Only) Do not install appliance in a sleeping room. An outside air inlet must be provided. The structural integrity of the manufactured home’s floor, walls, and ceiling must be maintained.

Flue connector pipe must be 6” diameter, minimum 24 MSG blue steel. Chimney must be factory built 103HT or masonry construction.

Contact Local Building or Fire Officials About Restrictions and Installation Inspection In Your Area.

DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY SERVING ANOTHER APPLIANCE. FOR USE WITH SOLID WOOD FUEL ONLY Do not burn coal.

DO NOT Overfire - If Heater or chimney connector glows, you are overfiring.

Optional Blower Harman #1-00-797032:Electrical Rating 115 VAC, 60Hz, 1AMP Maximum Route power cord away from unit.

Replace glass only with 5mm ceramic, available from your dealer. Combustible flooring must be protected with an approved 0.45R hearth board.

Appliance must be installed with the legs attached. Do not obstruct airflow under the appliance.

DANGER: Risk of Fire or Explosion - Do not burn garbage, gasoline, drain oil or other flammable liquids.

WARNING: Risk of Fire

l’installation doit au minimum être conforme aux exigences de la norme NFPA 211 aux É.-U. Voir dans les recommandations du fabricant et dans les codes locaux les précautions quant au passage d’une cheminée à travers un mur ou un plafond combustible.

MISE EN GARDE POUR LES MAISONS PRÉFABRIQUÉES : (É.-U. seulement) N’installez pas cet appareil dans une chambre à coucher. Une arrivée d’air de combustion extérieur doit être prévue. L’intégrité structurelle du plancher, des murs et du plafond de la maison préfabriquée doit être maintenue.

Le tuyau de raccord à la cheminée doit être d’un diamètre de 15,25 cm (6 po), au minimum en acier bleu 24 MSG. La cheminée doit être en métal 103HT d’usine ou construite en maçonnerie.

NE RELIEZ PAS CE POÊLE À UNE CHEMINÉE QUI SERT POUR UN AUTRE APPAREIL.

IL NE FAUT UTILISER QUE DU BOIS EN BUCHES. Ne chauffez pas TROP. Si l’appareil ou le raccord de cheminée rougit, c’est que le feu est trop puissant. Éloignez le cordon électrique de l’appareil.

DANGER: Risque de décharge électrique. Débranchez la prise avant tout entretien. Pour plus de détails, consultez le mode d’emploi.

Ne remplacez le verre que par du verre céramique de 5 mm à obtenir de votre détaillant.

L’appareil doit être installé avec ses pieds fixés. N’obstruez pas le passage d’air sous l’appareil.

CLEARANCE TO COMbUSTIbLES /

DISTANCES MINIMALES DE SECURITE:

Parallel

Inches

Millimeters

Installation

A

Back Wall / Entre mur arriereet l’appareil

14

330

b

Side Wall To Unit / Entre mur lateral et l’appareil

17

432

C

Back Wall To Flue Pipe / Entre tuyau et le mur arriere

17.5

444

D

Side Wall To Flue Pipe / Entre tuyau et le mur lateral

26.75

679

A

C

F

E

 

 

D

 

 

 

b

E

 

 

F

 

 

 

Corner

Inches

Millimeters

Installation

E Walls to Unit Body / Entre mur adjacent et l’appareil

14

330

F Walls to Flue Pipe / Entre tuyau et le mur adjacent

21.75

552

Floor Protection

Inches

Millimeters

Requirements

G

Sides / Côtés

8

203

H

Front- from glass/Devant, par rapport au verre

18

457

J

Rear / Arrière

8

203

J

Floor protection must be a minimum 3/8”

(9.5mm) of 0.84k material, or 0.45R. Must also

 

be placed under any horizontal sections of

 

flue connector, extending 2” (51mm) beyond

 

the measurement of the pipe. Use of bottom

G

G heat shield required on protected floor.

 

Pour protéger le plancher, il faut sous le

 

poêle un matériau (9.5mm / 0.84k), o 0.45R.

 

Qui doit aussi être placé sous les parties

H

horizontales du tuyau de raccord à la

 

cheminée et s’étendre à 51 mm (2 po) au-delà

 

de la mesure du tuyau.

Do not operate with fuel loading or ash removal doors open. Do not store fuel or combustibles within marked clearances.

Inspect and clean chimney and connector regularly- Under certain conditions of use, creosote buildup may occur rapidly.

The Bypass Damper must be opened prior to opening any load or ash door. Do not install a grate or otherwise elevate the fire.

DANGER: Risque d’incendie ou d’explosion. Ne brûlez pas d’ordures, d’essence, d’huile de vidange ni aucun autre liquide inflammable.

MISE EN GARDE: Risque d’incendie.

N’utilisez pas le poêle lorsque les portes du foyer et du cendrier sont ouvertes. Gardez le carburant et les matériaux combustibles

en dehors des dégagements prescrits.

Inspectez et nettoyez fréquemment les conduits et la cheminée.

REFER TO MANUFACTURER’S INSTRUCTIONS

Made in U.S.A. of US and imported parts. / Fabriqué aux États-Unis-

FOR CLEARANCES WITH ADDITIONAL VENT

d’Amérique par des pièces d’origine américaine et pièces importées.

CONFIGURATIONS.

Date of Manufacture / Date de fabrication:

2010 2011 2012 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC

P.N. 3-90-797

Fabriqué par: Harman Home Heating 352 Mountain House Road, Halifax PA 17032 (É.-U.)

IGN

 

2 Dry Seasoned Wood Only!

3-90-798

Image 2
Contents Installation and Operation ModelOakleaf Woodburning Stove Table of Contents Mobile Home Approved This appliance is also approved for installation in a shop1Listing and Code Approvals If the alarm sounds 2Special Warnings and Notes3Getting Started Design, Installation & Location ConsiderationsFire Safety Appliance LocationComponent Locations Flue Direction ConversionPre- Use Check List Fire Risk4Dimensions & Clearances Appliance DimensionsClearances To Combustibles 17 / 432 mm 14 / 356 mm 26.75 / 679 mm *17.5 / 444 mmClearance to Combustibles Requirements Floor Protection RequirementsFloor Protection Floor Protection RequirementsDraft Chimney ConnectorsChimneys and Venting Wall Pass-thrusAN Approved Canadian Wall PASS-THROUGH ChimneyVenting to a Masonry Chimney Installing to a Prefabricated ChimneyExisting Masonry Chimneys Venting to a Masonry Fireplace ChimneyChimney Cap Storm Collar Sections Roof Flashing Airtight insulated Clean-out Stainless Steel Chimney Connector Must Extend to Flue Liner Full Relining Fireplace Conversion Freestanding Appliance Chimney Breach Fireplace Conversion with Combustible Wall Mobile Home Installation 6Mobile HomeOptional Cooking Grill Appliance Set-UpOutside Air Attachment Leveling the Appliance Optional Bottom Heat Shield Optional Blower InstallationOptional Rear-vent Rear Shield 8Operating Instructions Fuel SpecificationsAlways wear fire retardant Gloves when operating the stove General Operating InformationDoors Or change the configuration of this grate systemCombustion Process GratesBuilding and Maintaining a Fire User ControlsBefore Your First Fire Oakleaf Woodburning Stove Creosote- Formation and Need For Removal 9Service & MaintenanceSeasonal cleaning By User Wear Leather Gloves To Prevent Skin Burns General Maintenance ProceduresAsh Removal Door GlassFirebox Chimney ConnectorBlower- If installed ChimneyOakleaf Optional Blower Kit #1-00-797032 Wiring Diagram 10Reference MaterialsService Parts OakleafStocked At depotStocked at depot Grams Per Hour 50% 60% 70% 80% 90% 100%Limited Lifetime Warranty Hearth & Home Technologies IncWarranty Conditions This warranty is void ifService & Maintenance Log Page Proudly Printed On 100% Recycled Paper