Harman Stove Company 1-90-797000 manual Floor Protection Requirements

Page 12

Oakleaf Woodburning Stove

C. Floor Protection Requirements

DANGER: The appliance legs may not be removed for installation.

 

L

J

J

 

K

Minimum Size floor protection (USA) is 48" Deep By 32.5" Wide.

Floor Protection

Inches

Millimeters

Requirements

 

 

J

Sides- USA /CANADA *

8

203

 

 

 

 

K

Front- USA /CANADA *

18

457

L

Rear- USA

8

203

L

Rear- CANADA

Wall

Wall

*Floor protection for the front and sides as mea- sured from the appliance door opening.

Floor Protection Requirements

If the Oakleaf is being installed on a combustible floor, the bottom heat shield (part # 1-00-797058) must be installed along with proper floor protection material. (See page 25). Floor protection must be a minimum 3/8" (9.5mm) thickness of material having an insulating value equal to or better than 0.84k/in. (The lower the k value, the better the protection.)

Another method for calculating floor protection is in R value. This requirement would be for an R value of

0.45or higher. (The higher the R value, the better the protection). Example- 1 inch of Durock® = 0.52R

In all installations, the area under and around the stove must be protected from falling ash and live coals. The area under a horizontal run of chimney connector must also be protected, extending two (2) inches be- yond the measurement of the horizontal connector.

Further guidelines for floor protection are as fol- lows:

In the U.S. the floor protector must be completely under the stove, and extending 16" in front of the door opening, 8" to each side and 8" to the back.

In Canada, the floor protection must extend 18" (457mm) in front of the door opening, 8" (203mm) to each side and extend to the wall behind the stove.

Minimum 60" corner floor protection (USA & CANADA).

60" / 1524 mm

12 Dry Seasoned Wood Only!

3-90-798

Save These Instructions

Image 12
Contents Installation and Operation ModelOakleaf Woodburning Stove Table of Contents This appliance is also approved for installation in a shop 1Listing and Code ApprovalsMobile Home Approved If the alarm sounds 2Special Warnings and NotesDesign, Installation & Location Considerations Fire Safety3Getting Started Appliance LocationComponent Locations Flue Direction ConversionPre- Use Check List Fire Risk4Dimensions & Clearances Appliance DimensionsClearances To Combustibles 17 / 432 mm 14 / 356 mm 26.75 / 679 mm *17.5 / 444 mmClearance to Combustibles Floor Protection Requirements Floor ProtectionRequirements Floor Protection RequirementsChimney Connectors Chimneys and VentingDraft Wall Pass-thrusAN Approved Canadian Wall PASS-THROUGH ChimneyInstalling to a Prefabricated Chimney Existing Masonry ChimneysVenting to a Masonry Chimney Venting to a Masonry Fireplace ChimneyChimney Cap Storm Collar Sections Roof Flashing Airtight insulated Clean-out Stainless Steel Chimney Connector Must Extend to Flue Liner Full Relining Fireplace Conversion Freestanding Appliance Chimney Breach Fireplace Conversion with Combustible Wall Mobile Home Installation 6Mobile HomeAppliance Set-Up Outside Air Attachment Leveling the ApplianceOptional Cooking Grill Optional Blower Installation Optional Rear-vent Rear ShieldOptional Bottom Heat Shield Fuel Specifications Always wear fire retardant Gloves when operating the stove8Operating Instructions General Operating InformationOr change the configuration of this grate system Combustion ProcessDoors GratesUser Controls Before Your First FireBuilding and Maintaining a Fire Oakleaf Woodburning Stove 9Service & Maintenance Seasonal cleaningCreosote- Formation and Need For Removal General Maintenance Procedures Ash RemovalBy User Wear Leather Gloves To Prevent Skin Burns Door GlassChimney Connector Blower- If installedFirebox ChimneyOakleaf Optional Blower Kit #1-00-797032 Wiring Diagram 10Reference MaterialsService Parts OakleafStocked At depotStocked at depot Grams Per Hour 50% 60% 70% 80% 90% 100%Limited Lifetime Warranty Hearth & Home Technologies IncWarranty Conditions This warranty is void ifService & Maintenance Log Page Proudly Printed On 100% Recycled Paper