LEAK TESTING HEATER GAS CONNECTIONS:

1.Open manual shutoff valve.

2.Open main gas valve located near gas meter.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from manual gas valve up to gas control and including the manifold assembly. Apply the soap solution around the connections, valve and tubing. Soap bubbles will appear where a leak is present.

5.If a leak is present, immediately turn off gas supply, tighten any leaky fittings, turn gas on and recheck.

6.To check burner and safety valve, the burner must be lit (See operating Instructions.). Check the rest of the connections for leaks.

7.Turn off the heater (See Instructions.).

Manual

Shutoff

Valve

Open

Closed

Manual Shutoff Valve

Combination

Gas Control Location

Manual

Shutoff

Valve

Checking Gas Joints

NOTE:

Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

OPERATING HEATER:

WARNING:

Before lighting, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. If you smell gas, follow the Safety Instructions on the front page and under Section I.

Page 13

Image 13
Contents GAS-FIRED Room Heater Contents Precautions General Safety InstructionsLocal Codes Product IdentificationUnpacking Product FeaturesFresh AIR for Combustion and Ventilation Adequate COMBUSTION/VENTILATION AIRUnconfined Space Locating HeaterConfined Space Attaching Mounting Brackets To Wall Preparing For InstallationAttaching to wall anchor method Installing Bottom Mounting ScrewsWall Mounted & Floor Mounted With Base Provided Typical Gas Supply Pipe Diameters Connecting to GAS SupplyBefore Testing Pressure TESTING-GAS Supply Piping SystemLeak Checking LOG Placement Operating Heater Leak Testing Heater GAS ConnectionsIGN Lighting InstructionsTurning OFF GAS to Heater Thermostat Control OperationInspecting Main Burner and Pilot Burner Manual Lighting InstructionsPilot Flame Pattern CorrectincorrectCare and Maintenance Problem Possible Cause What to do TroubleshootingProblem Possible Cause What to do Do not USE this Heater AT AN Elevation Above 4,500 Feet SpecificationsParts List Part NO. for Limited Warranty Save this Card