TROUBLESHOOTING:
PROBLEM | POSSIBLE CAUSE | WHAT TO DO | ||
|
|
|
| |
When control knob | 1. Ignitor electrode posi- | 1. | Replace Ignitor | |
is pressed in and |
| tioned wrong. |
| electrode. |
turned counterclockwise | 2. | Ignitor electrode broken. | 2. | Replace electrode. |
to ignition, there is no | 3. | Ignitor cable pinched or | 3. | Free ignitor cable, if |
spark at ODS pilot. |
| broken. |
| damaged replace it. |
| 4. Ignitor cable not connected | 4. Connect cable to | ||
|
| to ignitor electrode. |
| electrode. |
When control knob is pressed in and turned counterclock- wise to ignition/pilot position, there is spark but no ignition.
1.Gas supply turned off.
2.Control knob not in pilot position.
3.Control knob not pressed in while in pilot position.
4.ODS pilot is clogged.
5.Air in gas Lines.
1.Turn on gas supply.
2.Turn control knob to pilot position.
3.Press in control while in pilot position.
4.Call a qualified person
5.Purge gas lines and repeat ignition operation.
ODS pilot lights but | 1. Control knob not pressed | 1. After ODS pilot lights, |
flame goes out when | long enough. | keep control knob |
control knob is |
| pressed in approx. 30 |
released. |
| sec. |
| 2. Safety interlock is triggered. | 2. Wait a minute, repeat |
|
| ignition operation. |
| 3. Pilot flame not touching | 3. Contact your gas |
| the thermocouple. Problem | company or gas |
| could be result of one or | supplier or qualified |
| both of the following: | service person. |
| Partially clogged ODS pilot |
|
| orifice. |
|
| Low gas pressure. |
|
| 4. Thermocouple damaged. | 4. Replace thermocouple. |
| 5. Thermocouple connection | 5. Hand tight until snug |
| loose at gas control valve. | then tighten 1/4 turn |
|
| with a wrench. |
| 6. Gas control valve damaged. | 6. Replace gas control. |
|
|
|
Burner does not light | 1. Burner orifice clogged. | 1. Clean burner orifice. |
after ODS pilot is lit | 2. Gas supply pressure is very | 2. Contact the Gas Co. |
| low. |
|
Delayed ignition | 1. Main burner carry over ports |
| clogged. |
| 2. Gas supply pressure is very |
| low. |
1.Clean main burner ports.
2.Call your gas supplier.