Gas-Fired Products KLH601, 602-30 Troubleshooting, Problem Possible Cause What to do

Page 18

TROUBLESHOOTING:

PROBLEM

POSSIBLE CAUSE

WHAT TO DO

 

 

 

 

When control knob

1. Ignitor electrode posi-

1.

Replace Ignitor

is pressed in and

 

tioned wrong.

 

electrode.

turned counterclockwise

2.

Ignitor electrode broken.

2.

Replace electrode.

to ignition, there is no

3.

Ignitor cable pinched or

3.

Free ignitor cable, if

spark at ODS pilot.

 

broken.

 

damaged replace it.

 

4. Ignitor cable not connected

4. Connect cable to

 

 

to ignitor electrode.

 

electrode.

When control knob is pressed in and turned counterclock- wise to ignition/pilot position, there is spark but no ignition.

1.Gas supply turned off.

2.Control knob not in pilot position.

3.Control knob not pressed in while in pilot position.

4.ODS pilot is clogged.

5.Air in gas Lines.

1.Turn on gas supply.

2.Turn control knob to pilot position.

3.Press in control while in pilot position.

4.Call a qualified person

5.Purge gas lines and repeat ignition operation.

ODS pilot lights but

1. Control knob not pressed

1. After ODS pilot lights,

flame goes out when

long enough.

keep control knob

control knob is

 

pressed in approx. 30

released.

 

sec.

 

2. Safety interlock is triggered.

2. Wait a minute, repeat

 

 

ignition operation.

 

3. Pilot flame not touching

3. Contact your gas

 

the thermocouple. Problem

company or gas

 

could be result of one or

supplier or qualified

 

both of the following:

service person.

 

Partially clogged ODS pilot

 

 

orifice.

 

 

Low gas pressure.

 

 

4. Thermocouple damaged.

4. Replace thermocouple.

 

5. Thermocouple connection

5. Hand tight until snug

 

loose at gas control valve.

then tighten 1/4 turn

 

 

with a wrench.

 

6. Gas control valve damaged.

6. Replace gas control.

 

 

 

Burner does not light

1. Burner orifice clogged.

1. Clean burner orifice.

after ODS pilot is lit

2. Gas supply pressure is very

2. Contact the Gas Co.

 

low.

 

Delayed ignition

1. Main burner carry over ports

 

clogged.

 

2. Gas supply pressure is very

 

low.

1.Clean main burner ports.

2.Call your gas supplier.

Page 18

Image 18
Contents GAS-FIRED Room Heater Contents General Safety Instructions PrecautionsProduct Identification Local CodesFresh AIR for Combustion and Ventilation Product FeaturesUnpacking Adequate COMBUSTION/VENTILATION AIRLocating Heater Unconfined SpaceConfined Space Preparing For Installation Attaching Mounting Brackets To WallInstalling Bottom Mounting Screws Attaching to wall anchor methodWall Mounted & Floor Mounted With Base Provided Connecting to GAS Supply Typical Gas Supply Pipe DiametersPressure TESTING-GAS Supply Piping System Before TestingLeak Checking LOG Placement Leak Testing Heater GAS Connections Operating HeaterLighting Instructions IGNThermostat Control Operation Turning OFF GAS to HeaterPilot Flame Pattern Manual Lighting InstructionsInspecting Main Burner and Pilot Burner CorrectincorrectCare and Maintenance Troubleshooting Problem Possible Cause What to doProblem Possible Cause What to do Specifications Do not USE this Heater AT AN Elevation Above 4,500 FeetParts List Part NO. for Limited Warranty Save this Card