Note : The thermostat sensing bulb measures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation location, room size etc.). Frequent use of your heater will let you determine your own comfort levels.

MANUAL LIGHTING INSTRUCTIONS

1.Remove lower front panel.

2.Follow steps 1 through 4 as stated under Lighting Instructions.

3.Press and turn control knob counterclockwise to the PILOT position.

4.With control knob pressed in, strike match, hold match to pilot until pilot lights.

5.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

6.Replace lower front panel.

INSPECTING MAIN BURNER AND PILOT BURNER

Pilot Flame Pattern

The following figures show a correct and incorrect flame patterns. The incorrect flame is not touching the thermocouple. This will cause a nuisance shut down.

Thermocouple

Pilot Burner

Thermocouple

Pilot Burner

 

 

CORRECTINCORRECT

If pilot flame pattern is incorrect as shown above, turn heater off and refer to troubleshooting guide.

Burner Flame Pattern

This heater allows the view of flames and provides the simulation of a solid fuel fireplace. The incorrect log position can cause flame impingement, which can cause soot formation. Propane installations seem to have more of a sooting problem due to the richness of LP gas.

Page 16

Image 16
Contents GAS-FIRED Room Heater Contents General Safety Instructions PrecautionsProduct Identification Local CodesProduct Features UnpackingFresh AIR for Combustion and Ventilation Adequate COMBUSTION/VENTILATION AIRUnconfined Space Locating HeaterConfined Space Preparing For Installation Attaching Mounting Brackets To WallInstalling Bottom Mounting Screws Attaching to wall anchor methodWall Mounted & Floor Mounted With Base Provided Connecting to GAS Supply Typical Gas Supply Pipe DiametersBefore Testing Pressure TESTING-GAS Supply Piping SystemLeak Checking LOG Placement Leak Testing Heater GAS Connections Operating HeaterLighting Instructions IGNThermostat Control Operation Turning OFF GAS to HeaterManual Lighting Instructions Inspecting Main Burner and Pilot BurnerPilot Flame Pattern CorrectincorrectCare and Maintenance Troubleshooting Problem Possible Cause What to doProblem Possible Cause What to do Specifications Do not USE this Heater AT AN Elevation Above 4,500 FeetParts List Part NO. for Limited Warranty Save this Card