Gas-Fired Products KLH601 Attaching to wall anchor method, Installing Bottom Mounting Screws

Page 8

1.Install mounting brackets on wall as shown in Figure 2. Use enclosed “paper template” for proper location of holes. It may be necessary to use plastic or lead anchors for plaster walls.

2.Drill holes at marked locations using 9/64"drill bit.

3.Insert mounting screws through bracket and into wall studs.

4.Tighten screws until mounting bracket is firmly fastened to wall studs.

Attaching to wall anchor method

For attaching mounting bracket to hollow walls(wall areas between studs) or solid walls (concrete or masonry):

1.Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1 inch deep.

2.Insert the plastic anchor as shown in Figure 3 below:

Figure 3

3. Tap anchor flush to wall as shown in Fig.4

Figure 4

4.Insert mounting screws through each bracket and into wall anchors.

5.Tighten screws until mounting bracket is firmly fastened to wall.

Installing Bottom Mounting Screws

1.Locate two bottom mounting holes. These holes are near bottom on back panel of heater (See Figure 5.).

2.Mark screw locations on wall.

3.Remove heater from mounting bracket.

4.If installing bottom mounting screws into hollow or solid wall, install wall anchors. Follow steps 1 through 4 under, "Attaching To Wall Anchor Method", page 8. If installing bottom mounting screw into wall stud, drill holes at marked locations using 9/64drill bit.

5.Replace heater onto mounting bracket.

6.Place spacers between bottom mounting holes and wall anchor or drilled hole.

7.Hold spacer in place with one hand. With other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall

Page 8

Image 8
Contents GAS-FIRED Room Heater Contents General Safety Instructions PrecautionsProduct Identification Local CodesProduct Features UnpackingFresh AIR for Combustion and Ventilation Adequate COMBUSTION/VENTILATION AIRConfined Space Locating HeaterUnconfined Space Preparing For Installation Attaching Mounting Brackets To WallInstalling Bottom Mounting Screws Attaching to wall anchor methodWall Mounted & Floor Mounted With Base Provided Connecting to GAS Supply Typical Gas Supply Pipe DiametersLeak Checking Pressure TESTING-GAS Supply Piping SystemBefore Testing LOG Placement Leak Testing Heater GAS Connections Operating HeaterLighting Instructions IGNThermostat Control Operation Turning OFF GAS to HeaterManual Lighting Instructions Inspecting Main Burner and Pilot BurnerPilot Flame Pattern CorrectincorrectCare and Maintenance Troubleshooting Problem Possible Cause What to doProblem Possible Cause What to do Specifications Do not USE this Heater AT AN Elevation Above 4,500 FeetParts List Part NO. for Limited Warranty Save this Card