SOLVING COMMON PROBLEMS

The 3 most common problems associated with any gas heater are gas leaks, wrong gas pressure and dirt.

Do Not Use Your Heater Without Checking For Leaks! Leaks can occur during shipment and installation. A simple solution of soap and water dabbed on the fittings will bubble if a gas leak is present. Do not take short cuts!

Wrong Gas Pressure! Too much gas pressure may severely damage your heater. Too little gas pressure and your heater will not burn correctly. If your installer can not check gas pressure, find one who can or call your gas supplier. Do not take shortcuts!

Dust & Dirt! This heater does require some cleaning. If the pilot light will not stay lit or if one brick is not as bright as another, your heater is probably due for a good cleaning.

Replacement of the thermocouple or pilot assembly is generally not needed. Review Heater Maintenance on page 15 of the owners manual.

While we want every one to be completely satisfied with their purchase it is impossible to cover problems occurring form improper installation or a lack of maintenance.

Kozy-World Warranty Registration

IMPORTANT: We urge you to fill out your warranty registration card within ten(10) days of date of installation, complete with the entire serial number which can be found on the rating plate. Retain this portion of the card for your records.

World Marketing of America, Inc.

PO Box 192, Route 22 West

Mill Creek, PA 17060-0192

Tel) 1-814-643-2299

SAVE THIS CARD!

Place

Postage

Stamp

Here

World Marketing of America, Inc.

PO Box 192, Route 22 West

Mill Creek, PA 17060-0192

Image 24
Contents GAS-FIRED Room Heater Contents General Safety Instructions PrecautionsProduct Identification Local CodesProduct Features UnpackingFresh AIR for Combustion and Ventilation Adequate COMBUSTION/VENTILATION AIRLocating Heater Unconfined SpaceConfined Space Preparing For Installation Attaching Mounting Brackets To WallInstalling Bottom Mounting Screws Attaching to wall anchor methodWall Mounted & Floor Mounted With Base Provided Connecting to GAS Supply Typical Gas Supply Pipe DiametersPressure TESTING-GAS Supply Piping System Before TestingLeak Checking LOG Placement Leak Testing Heater GAS Connections Operating HeaterLighting Instructions IGNThermostat Control Operation Turning OFF GAS to HeaterManual Lighting Instructions Inspecting Main Burner and Pilot BurnerPilot Flame Pattern CorrectincorrectCare and Maintenance Troubleshooting Problem Possible Cause What to doProblem Possible Cause What to do Specifications Do not USE this Heater AT AN Elevation Above 4,500 FeetParts List Part NO. for Limited Warranty Save this Card