RELIEF VALVE

1.Disconnect power from unit.

2.Shut off incoming water supply.

3.Lift test lever on relief valve to relieve pressure in tank.

4.Disconnect overflow piping.

5.Unscrew relief valve, remove assembly and replace with new one.

6.Connect overflow piping.

7.Turn on incoming water supply and check for leaks.

8.Turn safety switch to ON position.

Test Lever

Overflow Piping Outlet

Tank Connection

Temperature Probe

19

Image 19
Contents Electric Heater Company STRATFORD, CT Hubbell Electric Heater CompanyTable of Contents Section Title Page Control Thermostat Section I General Description and ConstructionTank Tank ConnectionsHeating Element Temperature High Limit SwitchOuter Shell and Insulation Magnetic Contactor HSE Models OnlyWater Heater Placement Section II InstallationPiping Installation Filling the Heater Electrical InstallationFinal Checks Quarterly Inspection Section III Scheduled Maintenance and OperationMaintenance and Operation FreezingAnnual Inspection Symptom Probable Cause Corrective Action / Remedy Section IV TroubleshootingSurface Temperature High Limit CUT-OFF Section V Servicing & Replacement of PartsHeating Element Page Immersion Thermostat Magnetic Contactor Relief Valve Delta WYE Single Phase Element Chart Torque Values