SENSOR PROBE

1.Disconnect power from unit.

2.Shut off incoming water supply.

3.Attach hose to drain connection.

4.Lift manual release lever on relief valve to let air into system or break union on outgoing water line.

5.Drain water from tank.

6.Disconnect probe wire from control board. (See picture)

Probe connection (J3)

7.Remove probe from tank using a 13/16” slotted socket or 13/16” spark plug wrench to accommodate the probe cable.

NOTE: Care should be taken not to pull or put excessive force on the cable to probe connection.

8.Install new #115 Buna-N o-ring gasket and install new probe. NOTE: Hubbell recommends lubricating the o-ring with Parker O-Lube prior to installation. WARNING: Do not remove the jam nut. To replace the probe, remove the entire probe assembly from the tank.

Probe

9.Reconnect probe wire to control board.

10.Refill tank.

11.Check for leaks. Retighten as required.

12.Note that to resume operation the controller will need to be reset by pressing the ‘RESET’ button on the display.

CAUTION: Do not use plumber’s tape/Teflon tape/pipe dope when installing the probe. Tape will prevent the low water detection system from operating properly and will cause false low water errors. Lubricate O- ring prior to installation.

Tighten probe at the brass hex flats only. Use a 13/16” open ended socket or spark plug wrench. Do not apply pressure, twist, or turn the black wire or the stainless steel jam nut, as this will damage the probe.

28

Image 28
Contents Operating and Maintenance Manual for Electric Booster Heater Hubbell Electric Heater Company Seymour Street STRATFORD, CTTable of Contents Section Title Section I General Description and Construction CapacityPage Power Circuit Breakers Construction TankTank Connections Heating ElementPressure Reducing Valve Dial Temperature and Pressure GaugeOptional Equipment Water Heater Placement Section II Installation and START-UPSlide Brackets for Hanging Support Mounting Manual Release Lever Optional XB1 LOW Temperature Interlock Electrical InstallationFilling the Heater Optional Remote Alarm Contacts Common noFor Remote ON/OFF Control Final ChecksWiring Chart Diagram 1WT 1NT WT L1 L2 L3 13 NT NCB L1 L2 L3 Page Section III Scheduled Maintenance and Operation Maintenance and OperationFreezing Controller OperationQuarterly Inspection Section IV Troubleshooting Error Messages Err, No, H2OContactor Care MiscellaneousTroubleshooting Flow Charts OK?Continuous No Display Is the circuit Breaker tripped at Source? Section V Servicing & Replacement of Parts Control Board Relief ValveSensor Probe Section VI Service Parts List Category Description Volts Ohms Hubbell P/NPart Wire Size Torque inlbs Torque ftlbs Section VII Torque ValuesSection Viii Warranty Information Limited Warranty Such Warranties do not Cover