EL296UHE Gas Furnace

The EL296UHE Category IV gas furnace is shipped ready for installation in the upflow or horizontal position. The fur­ nace is shipped with the bottom panel in place. The bot­ tom panel must be removed if the unit is to be installed in horizontal or upflow applications with bottom return air.

The EL296UHE can be installed as either a Direct Vent or a Non-Direct Vent gas central furnace.

The furnace is equipped for installation in natural gas ap­ plications. A conversion kit (ordered separately) is re­ quired for use in propane/LP gas applications.

NOTE - In Direct Vent installations, combustion air is taken from outdoors and flue gases are discharged outdoors. In Non-Direct Vent installations, combustion air is taken from indoors or ventilated attic or crawlspace and flue gases are discharged outdoors. See figures 1 and 2 for applications in­ volving roof termination.

DIRECT VENT INSTALLATION

NON-DIRECT VENT

EXHAUST OUTLET

INSTALLATION

COMBUSTION

EXHAUST

AIR INTAKE OUTSIDE

OUTLET

OF HOUSE

 

COMBUSTION

AIR INTAKE

INSIDE

OF HOUSE

FIGURE 1

NON-DIRECT VENT

NON-DIRECT VENT

INSTALLATION

INSTALLATION

EXHAUST

EXHAUST

OUTLET

OUTLET

 

 

COMBUSTION

COMBUSTION

AIR INTAKE INSIDE

VENTILATED

AIR INTAKE INSIDE

CRAWL SPACE

VENTILATED

 

ATTIC SPACE

 

FIGURE 2

Shipping and Packing List

Package 1 of 1 contains

1 - Assembled EL296UHE unit

1 - Bag assembly containing the following:

1- Snap bushing

1- Snap plug

1- Wire tie

1- Condensate trap

1- Condensate trap cap

1- Condensate trap clamp

1- 2” diameter debris screen

1- 3/4” Threaded street elbow

Check equipment for shipping damage. If you find any damage, immediately contact the last carrier.

The following items may also be ordered separately: 1 - Thermostat

1 - LP/Propane changeover kit

1 - Return air base kit

1 - Horizontal suspension kit

1 - High altitude pressure switch

Safety Information

CAUTION

As with any mechanical equipment, personal injury can result from contact with sharp sheet metal edges. Be careful when you handle this equipment.

DANGER

Danger of explosion.

There are circumstances in which odorant used with LP/propane gas can lose its scent. In case of a leak, LP/propane gas will settle close to the floor and may be difficult to smell. An LP/propane leak detector should be installed in all LP applications.

Use only the type of gas approved for use with this furnace. Refer to unit nameplate.

EL296UHE units are CSA International certified to ANSI Z21.47 and CSA 2.3 standards.

Building Codes

In the USA, installation of gas furnaces must conform with lo­ cal building codes. In the absence of local codes, units must be installed according to the current National Fuel Gas Code (ANSI‐Z223.1/NFPA 54). The National Fuel Gas Code is available from the following address:

American National Standards Institute, Inc.

11 West 42nd Street

New York, NY 10036

In Canada, installation must conform with current National Standard of Canada CSA‐B149 Natural Gas and Propane Installation Codes, local plumbing or waste water codes and other applicable local codes.

Page 3

Image 3
Contents Table of Contents Installation Instructions EL296UHETOP View EL296UHE Unit Dimensions inches mmPackage 1 of 1 contains Safety InformationEL296UHE Gas Furnace Shipping and Packing ListInstallation Locations Installed in Combination with a Cooling CoilUse of Furnace as Construction Heater Combustion, Dilution & Ventilation Air GeneralEquipment in Confined Space ALL AIR from Inside Confined SpaceAir from Inside Unconfined SpaceAir from Outside Equipment in Confined Space ALL AIR from OutsideEquipment in Confined Space EL296 Furnaces with 1/2 HP Blower Motor Installation Setting EquipmentShipping Bolt Removal Moved before the furnace is placed into operation. Af­END View Setting EquipmentFront View Side ViewSide Return Air With transition and filter Return Air GuidelinesOptional Return Air Base Upflow Applications Only Removing the Bottom PanelFrontBack Horizontal Suspension KIT Horizontal Application Installation ClearancesSuspended Installation of Horizontal Unit Platform Installation of Horizontal UnitPipe & Fittings Specifications FiltersDuct System Primer & Solvent Cement Joint Cementing ProcedurePiping and Fittings Specifications SpecificationRemoval of the Furnace from Common Vent Venting PracticesPiping Suspension Guidelines Wall Thickness GuidelinesMinimum Vent Pipe Lengths Horizontal Installation Offset RequirementsVent Piping Guidelines Exhaust Piping Figures 22, 24Piping Size Process Standard Concentric Outdoor Termination Usage135 Standard Termination Elevation 4500 10,000 ftMaximum Allowable Intake or Exhaust Vent Length in Feet Concentric Termination at Elevation 0 4500 ftConcentric Termination Elevation 4501 10,000 ft Standard Termination Elevation 4500 10,000 ft Applications Right Hand Discharge Shown Intake Piping General Guidelines for Vent Terminations 32 to 20 to Inside Corner Detail US Installations1 Canadian Installations2No minimum to outside corner Exiting Exhaust and Intake Vent Different pressure zones Direct Vent Roof Termination KITEL296UHE 51MM 76MM Alternate Terminations Tee & Forty-Five Degree Elbows OnlySupport 51MM 7MM Vent PipeSide View Front ViewTop View Exhaust NON-DIRECT Vent Roof Termination KIT EL296UHE Direct Vent Application Using Existing ChimneyCondensate Piping EL296UHE NON-DIRECT Vent Application Using Existing ChimneyCondensate Trap Locations Condensate Trap With Optional Overflow SwitchUnit shown in horizontal left-hand discharge position EL296UHE with Evaporator Coil Using a Common Drain178 Trap / Drain Assembly Using 1/2 PVC or 3/4 PVCGas Piping Leak CheckPlugged TAP Left Side Piping Standard Right Side Piping Alternate Horizontal Applications Possible Gas Piping ConfigurationsGAS Pipe Capacity FT3/HR kL/HR Precautions and ProceduresInterior MAKE-UP BOX Installation ElectricalOn-Board Links and Diagnostic Push Button Figure Typical EL296UHE Wiring Diagram LED Integrated ControlIntegrated Control DIP Switch Settings EL296 Field Wiring Applications With Conventional Thermostat Heat / 1 Cool OFFWith tstat with Humidity control7000 L7724U Single StageHeat Pump ComfortSenseOFF Unit Start-Up For Your Safety Read Before OperatingGas Pressure Adjustment GAS Meter Clocking ChartDial Proper Combustion High Altitude Information Carbon Monoxide Poisoning Hazard Heating Sequence of Operation Other Unit AdjustmentsBlower Parts Repair Parts ListCabinet Parts Control Panel PartsFilters ServiceCleaning The Burner Assembly BlowerTypical Start-Up & Performance Check ListVent Pipe Temperature RiseTotal External Static Drain Line Condensate Line ThermostatApproved Carbon Monoxide Detectors Requirements for Commonwealth of Massachusetts

EL296UHE, Elite Series Gas Furnace specifications

Lennox International Inc. has long been a trusted name in the heating, ventilation, and air conditioning (HVAC) industry, and their Elite Series Gas Furnace, the EL296UHE, stands out as a remarkable choice for homeowners seeking efficiency and reliability. This gas furnace is designed to deliver exceptional performance while ensuring the comfort of your living space.

One of the most significant features of the EL296UHE is its impressive Annual Fuel Utilization Efficiency (AFUE) rating of up to 96%. This means that a substantial portion of the energy consumed is converted into heat, translating to lower energy bills and a reduced environmental footprint. By minimizing energy waste, homeowners can enjoy both cost savings and greater environmental responsibility.

The EL296UHE is equipped with a two-stage heating process that allows it to operate at different speeds. This dual-stage functionality offers a more consistent temperature throughout the home, minimizing cold spots and enhancing overall comfort. Additionally, this furnace features a variable-speed blower motor, which not only improves the distribution of heated air but also quietly adjusts the airflow to match the heating requirements of your space.

In terms of technology, the EL296UHE incorporates advanced design elements such as a patented ZenBalanceā„¢ technology. This innovation further increases efficiency by adjusting the heating output based on real-time demands, ensuring optimal comfort without excessive energy consumption.

Durability is another hallmark of the EL296UHE. Constructed with high-quality materials, this furnace is built to withstand the rigors of daily use. Its stainless-steel heat exchanger is particularly noteworthy, as it enhances the furnace's ability to operate efficiently while maximizing longevity.

Homeowners are also reassured by the EL296UHE's quiet operation. The design minimizes operational noise, making it an ideal choice for those who prefer a peaceful home environment. Furthermore, the furnace is equipped with an ENERGY STARĀ® certification, a testament to its energy-efficient performance.

Lastly, Lennox offers comprehensive warranties for the EL296UHE, ensuring peace of mind for consumers. The combination of high efficiency, advanced technology, and durability makes the Lennox Elite Series Gas Furnace, EL296UHE, an excellent investment for homeowners looking to enhance their heating systems for optimal comfort and efficiency.