Installation of B-W Gas Vent

 

for one-story buildings or for

Ceiling plate spacers to center

first floor of multi-story

B-W Gas Vent in stud space -

buildings.

nail securely at both ends.

 

Plate cut away for full

 

width of stud space to

 

provide ventilation.

 

Studs on

Sheet metal screw base

16 inch centers

 

plate to header

 

Use manufacturer’s method of fastening pipe to base plate.

Installation of B-W Gas Vent for each subsequent ceiling or floor level of multistory buildings.

Firestop spacers supplied by manufacturer of B-W Gas Vent

Plate cut away to provide passage of B-W Gas Vent

Header plate of vented wall furnace (also acts as firestop)

FIGURE B

CONTROLS

All controls are pre-assembled at the factory. The normal manifold pressure should be 3.5” w.c. for Natural Gas and 10” w.c. for L.P. Gas. The maximum inlet pressure in the gas supply pipe should never exceed 7.0” w.c. for Natural Gas or 14” w.c. for L.P. Gas. The minimum inlet pressure in the gas supply pipe should never be lower than 4.5” w.c. for Natural Gas or 11” w.c. for L.P. Gas.

Nail firestop spacer securely

FIGURE C

NATURAL GAS

SPECIFIC ELEVATIONS

Model

0 to

2,000 -

4,000 -

6,000 -

8,000 -

No.

2,000’

4,000’

6,000’

8,000’

10,000’

CF353C

34

36

37

38

41

CF357C

34

36

37

38

41

CF503C

3.4mm

31

31

32

35

CF557C

29

30

30

31

32

CF653C

26

27

28

29

30

ORDER KIT #49840 2287-1 HIGH ALTITUDE KIT

L.P. GAS

SPECIFIC ELEVATIONS

Pilot Adj.

Screw

HONEYWELL VR8200H SERIES

STANDING PILOT FIGURE 10-A

Pilot Adj.

Screw

HONEYWELL VR8204H SERIES

I.I.D. PILOT

FIGURE 10-B

Model

0 to

2,000 -

4,000 -

6,000 -

8,000 -

No.

2,000’

4,000’

6,000’

8,000’

10,000’

CF354C

50

52

52

53

54

CF358C

50

52

52

53

54

CF504C

45

47

48

49

50

CF558C 2.15mm

45

47

48

49

CF654C

42

43

44

45

47

ORDER KIT #49840 2287-1 HIGH ALTITUDE KIT

The appliance is orificed at the factory for elevations up to 2,000 feet. If installed above 2,000 feet, the BTU input must be reduced 4% per 1,000 feet. See the following orifice chart for the proper orifice for a specific elevation.

PILOT ADJUSTMENT

Locate the pilot adjustment screw on the valve. The pilot flame should surround at least the top 3/8” of the powerpile (pilot generator) or flame sensor (see Figure 8). The pilot is unregulated so it will be operating at inlet line pressure (maximum 7” w.c. for Natural Gas and 11” w.c. for Propane Gas). To decrease the pilot flame, turn the screw clockwise (approximately six full turns to bottom of pilot light channel) until you produce sufficient flame at the minimum noise level.

PILOT FLAME ADJUSTMENT

3/8” TO 1/2”

3/8” TO

1/2”

STANDING PILOTI.I.D. PILOT

FIGURE8-AFIGURE8-B

PILOT FLAME SHOULD ENVELOP 3/8 TO ½ INCH

Page 9

OF THE TIP OF THE GENERATOR.

Image 9
Contents Byaqualified INSTALLER, Service Agency or Installation and Service Must be PerformedWhat to do Ifyou Smell GAS GAS SupplierContents Counterflow Wall Furnace SpecificationsIntroduction Safety Rules Read Carefully Before Installing UnitVenting See Listof Possiblecausesand Corrections on PAGE19 VentingCombustionandventilationair Location and Special Precautions ROUGH-IN InstructionsElectrical ROUGH-IN GAS ROUGH-IN Installation / When Recessed Installation When Installed Flush to WallPilot Flame Adjustment Pilot AdjustmentNatural GAS GASLighting Instructions Standing Pilot For Your Safety Read Before LightingTo Turn OFF GAS to Appliance What to do if YOU Smell GASGascontrol Knob Whatto do Ifyou SmellgasOperation Proper Burner FlameAuxiliary Limit Switch Maintenance InstructionsTerminal Block Wiring Diagram Pictorial Schematic CF353C-H, CF354C-H Pictorial SchematicSchematic Standing Pilot CF503/504C-H, CF653/654C-HModel no Amps PictorialROUGH-INS for Rear or Side Discharge Optional Accessory KitsRear SideSide Discharge on Casing Optional KitsModel NumberTrouble Shooting Chart Pilot and Valve Trouble Shooting Chart for qualified serviceman Main BurnerPossible Causes Corrective Action Symptom Possible Causes Corrective ActionControl Assembly ReplacementpartsCounterflow Wall Furnace / Standing Pilot USE OnlyfactorysuppliedVO LT System W ITH LO W -B.T.U. Standing Pilo T Requires TWOCounterflow Wall Furnace / I.I.D. Pilot NAT. GAS CF357C-H CF557C-HModels VO LT S YS TEM W ITH Intermittent IG Nitio N I.I.D KIT no 306SR-A Side Register Flush 30SRB-A Rear Register W Boot FlushKIT no Rear Register RecessREV /05 March Tampering is Dangerous Your GAS Control and Pilot Light SystemLimited

78111 specifications

Louisville Tin and Stove 78111 has firmly established itself as a leading provider of heating and cooling solutions in the heart of Louisville, Texas. Known for its commitment to quality craftsmanship and customer satisfaction, this company offers a diverse range of products tailored to meet a variety of residential and commercial needs. One of the standout features of Louisville Tin and Stove is its extensive selection of traditional and contemporary stoves, which include wood, gas, and pellet options. These stoves are designed to provide efficient heating while adding a touch of style to any space.

The technology behind the products at Louisville Tin and Stove focuses on efficiency and sustainability. Many of the stoves are engineered with advanced combustion systems that maximize heat output while minimizing emissions. This not only promotes environmental responsibility but also enhances the cost-effectiveness of heating systems. High-efficiency models are equipped with features such as automated ignitions, programmable thermostats, and even smart technology that allows users to control their heating systems remotely from their smartphones.

In addition to stoves, Louisville Tin and Stove specializes in custom metal fabrication. Whether it’s for a personalized chimney cap or a unique fireplace surround, the skilled craftsmen at this company can bring any vision to life. Their attention to detail and use of high-quality materials ensure that each piece is not only functional but also visually appealing.

Another critical characteristic of Louisville Tin and Stove 78111 is its focus on customer support. The knowledgeable staff is always on hand to provide expert advice on product selection, installation, and maintenance. This commitment to exceptional service ensures that customers feel confident in their purchases and satisfied with their heating solutions.

Overall, Louisville Tin and Stove 78111 combines traditional craftsmanship with modern technology, resulting in a product line that is both stylish and efficient. Whether you’re looking to upgrade your home’s heating system or need a bespoke metal piece, Louisville Tin and Stove stands ready to meet your needs with professionalism and expertise.