Empire Products FAW-40-1IP, FAW-40-1SPP Test de Pression du Système dAlimentation de Gaz

Page 26

TUYAU D’ALIMENTATION EN GAZ

VALVE DEFERMETURE MANUELLE

ARRIVÉE D’ALIMENTATION

DE GAZ

BONDE NPT DE 1/8” (3mm)

POUR VÉRIFIER LE

JAUGEAGE DES

CONNEXIONS(3mm)

VALVE À GAZ

RACCORDHORIZONTAL

VALVE VUE DE DESSUS

RÉGULATEUR DE

ÉVENT

PRESSION

 

 

CONNECTEUR TH/TR

 

 

PRISE POUR SORTIE DE

 

 

PRESSION

ENTRÉE DE GAZ

 

SORTIE DE GAZ

BOUTON ROUGE

 

 

PRESSION D’ENTRÉE

 

SORTIE DE GAZ POUR

 

 

 

 

VEILLEUSE

BOUTON ROUGHE DE

 

VIS D’AJUSTMENT

REMISE Á ZÉRO

 

POUR VEILLEUSE SOUS

 

Figure 9

COUVERCLE DE VIS

ROBINET MANUELDE GAZ

 

BONDE NPT DE 1/8”

3” (76mm) MINIMUM

(3mm) POUR VÉRIFIER

 

LE JAUGEAGE DES

 

(3mm)

 

CONNEXIONS

 

Figure 8

Méthode pour installer un collecteur de sédiment avec un adapteur en T L’emploi des connexions de gaz suivantes est recommandé.

ANS Z21.24 Connexions d’appareil de tuyaux et de raccords en métal ondulé.

ANS Z21.45 Connexions flexibles d’appareil autre qu’en métal. Les connexions ci-dessus peuvent être utilisées si elles sont acceptées par les autorités ayant juridiction.

Test de Pression du Système d'Alimentation de Gaz

1.Pour vérifier la pression d’arrivée de la valve de gaz, une bonde N.P.T. de 1/8" ( 3.175mm), accessible pour vérifier le jaugeage des connexions, doit être située immédiatement en amont de la connexion d’alimentation de gaz de l’appareil.

2.Pendant un test de pression du système d’alimentation de gaz, l’appareil et sa valve de fermeture doivent être débranchés si une pression supérieure à 1/2 psig (3.5kPa) est employée.

3.Pendant un test de pression du système d’alimentation de gaz, si une pression égale ou inférieure à 1/2 psig (3.5kPa) est employée, l’appareil doit être isolé du système d’alimentation de gaz en fermant sa propre valve de fermeture manuelle.

Attention! Si une des procédures ci-dessus occasionne une pression supérieure

à1/2 psig (14" w.c.) (3.5kPa )sur la valve de gaz de l’appareil, une situation dangereuse s’en suivra.

Vérifier les Pressions de Gaz

Un régulateur de pression est incorporé dans la valve de gaz propane et celle de gaz naturel. Les modèles pour le gaz naturel auront des pressions de gaz approxi- mativement de 4.0" w.c. (.996kPa) à la sortie de la valve et une pression d’entrée à la valve d’un minimum de 5.0" w.c. (1.24kPa) pour permettre l’ajustement à l’entrée, allant à un maximum de 10.5" w.c. (2.62kPa). Les modèles pour le gaz propane auront des pressions de gaz approximativement de 10.0" w.c. (2.5kPa)

àla sortie de la valve et une pression d’entrée à la valve d’un minimum de 11.0" w.c. (2.74kPa) pour permettre l’ajustement à l’entrée, allant à un maximum de 12.0" w.c. (3.24kPa).

Une bonde N.P.T. de 1/8" (3mm), accessible pour vérifier le jaugeage des con- nexions, est située sur le côté de la sortie de la commande de gaz.

Le régulateur incorporé se déclenche approximativement à 1/4 de la pression et s’ouvre au plus fort en 10 secondes.

Hautes Altitudes

Pour des altitudes/élévations au dessus de 2,000' (610m), les puissances d’entrée devront être réduites de 4% pour chaque 1,000' (305m) au dessus du niveau de la mer. Lors des applications pour hautes altitudes au Canada, cet appareil est approprié pour une installation à une élévation entre 0' (0m) et 4,500 (1372m) sans aucun changement.

Instructions pour le Piezo-Allumeur de la Veilleuse

Baisser le bouton rouge complètement provoquera une étincelle qui surviendra à la veilleuse. Ceci est un substitut à une allumette. Celle-ci exigerait l’ouverture du couvercle pour l’accès à la veilleuse.

Pour allumer la veilleuse, il est important que l’électrode soit à 1/8" (3mm) du thermocouple. L’étincelle doit se produire à l’endroit où la flamme du brûleur frappe le thermocouple. Le bout de l’électrode sera chauffé au rouge lorsque la veilleuse est en fonction.

Sur une nouvelle installation ayant de l’air dans la ligne de gaz, il est suggéré d’utiliser une allumette. Dans cette condition, l’allumette allumera la veilleuse plus vite qu’avec le piezo-allumeur.

THERMOCOUPLEFigure 9

BRÛLEUR

ÉLECTRODE VEILLEUSE D’ÉTINCELLE

VEILLEUSE FIXE

THERMOCOUPLE

ÉCRAN DE LA

ÉLECTRODE

VEILLEUSE

 

D’ÉTINCELLE

 

VUE DE L´EXTRÉMITÉ DE LA LOCALISATION DE LA VEILLEUSE

VEILLEUSE FIXE REPRÉSENTÉE

FLAMME DE LA VEILLEUSE

DE 3/8" (10mm) à 1/2" (13mm)

PRISE DE TERRE POUR

L´ÉLECTRODE

BRÛLEUR

VEILLEUSE

SURFACE

CHAUDE TIGE DE LA

D'ALLUMAGE FLAMME

VEILLEUSE MODÈLE IP

Figure 10

Aspect Convenable de la Flamme de la Veilleuse

La flamme de la veilleuse (Figure 10) sera bleue et s’allongera plus loin que le thermocouple. La flamme entourera le thermocouple juste en-dessous de la pointe.

Les veilleuses de gaz naturel exigent un ajustement lorsque la pression d’entrée de gaz est supérieure à 5.0" w.c. (1.25kPa). Enlever la vis du couvercle de la veilleuse sur la valve de contrôle (Figure 9) et tourner la vis d’ajustement dans le sens des aiguilles d’une montre pour réduire la flamme. Replacer la vis du couvercle de la veilleuse pour éliminer une fuite de gaz.

Le gaz propane n’exige aucun ajustement.

Après l’usage, un nettoyage peut être exigé pour obtenir une flamme convenable.

Page 8

12427(F)-3-0903

Image 26
Contents Installation Instructions Installation in Residential Garages Instructions to InstallerInstallation on Rugs and Tile 275 AccessoriesSafety Information for Users of LP-GAS Ventilation and Combustion Air Installation in an Unconfined SpaceInstallation in a Confined Space Ventilation Air Openings and DuctsClearances Qualified Installing AgencyBefore Installing Consider The Following Venting 102mm Oval In-The-Wall all parts purchase locallyInstalling Optional Side Outlets Installing Optional Rear OutletMethod of Installing a Tee Fitting Sediment Trap Installation of Three-prong Grounding Plug AssemblyInstalling a New Main Gas Cock Pressure Testing of the Gas Supply SystemHigh Altitudes Cleaning Combustion Exchanger AssemblyChecking Manifold Pressure Piezo Pilot Ignitor InstructionsVent Safety Shutoff System WiringThermostat Installation Oiling the MotorIf Pilot Does Not Light By Any Means Pilot Flame AdjustmentIf Electrode Does Not Produce Spark If Pilot Does Not Remain On After Releasing KnobFor Your Safety Read Before Lighting For Your Safety Read Before Operating Sequence of Operation IP System Troubleshooting Sequence Part number and description of part coincide Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave12427-4-0306 Service Notes Empire Comfort Systems, Inc Instructions Pour L’INSTALLATION Manuel DU Propriétaire Installation dans les Garages Residentiels Instructions pour lInstallateurInstallation sur un Tapis ou Tuile Informations GénéralesInformation DE Sécurité Pour LES Utilisateurs DE Propane Air de Ventilation et de Combustion Installation dans un Espace OuvertInstallation dans un Espace Restreint Ouvertures et Conduits pour l’Air de VentilationAgence d’Installation Qualifiée Espaces LibresInstallation des Sorties Optionnelles sur les Côtés Installation d’une Sortie Arrière OptionnelleEmplacement de lAlimentation Électrique Emplacement du Radiateur Sur le MurEmplacement de lAlimentation de Gaz Installation d’un Noveau Robinet PrincipalAspect Convenable de la Flamme de la Veilleuse Test de Pression du Système dAlimentation de GazInstallation du Thermostat Aspect Convenable de la Flamme du Brûleur PrincipalInstallation Électrique Ne pas installer le thermostat sur un mur extérieurSi l’électrode ne produit pas d’étincelle Appeler un technicien d’entretienVeilleuse modèle fixe En aucune façon, la veilleuse ne s’allume pasVeilleuse modèle IP Ajustement de la flamme de la veilleusePour Votre Sécurité Lire Avant D’ALLUMER Instructions DE Fonctionnement 12427F-3-0903 12427F-3-0903 Façon de Commander les Pièces de Réparation Veilleuse ET SUP Port Pour LES Modé LES SPP Empire Comfort Systems, Inc

FAW-40-1IP, FAW-40-1SPP specifications

Empire Products has established itself as a leader in the manufacturing of high-quality heating solutions, and among its standout offerings are the FAW-40-1SPP and FAW-40-1IP models. These heaters have been engineered to meet the demands of various environments, providing efficient heating solutions while prioritizing user convenience and energy efficiency.

The FAW-40-1SPP is a powerful unit designed for versatile applications, whether in residential or commercial settings. This model boasts a robust output that ensures rapid heating even in larger spaces. Its advanced control system allows users to easily adjust the temperature settings, ensuring that comfort is maintained regardless of external weather conditions. This model is also equipped with safety features, including overheat protection, which automatically shuts off the heater if it reaches an unsafe temperature, a crucial feature for maintaining safety in populated areas.

On the other hand, the FAW-40-1IP represents innovation with its integrated programmable features. This unit is specifically designed for more tech-savvy users looking for convenience. The programmable thermostat enables users to set heating schedules, allowing for automated adjustments based on their daily routines. This not only enhances user comfort but also contributes to energy savings by avoiding unnecessary heating when spaces are unoccupied. Moreover, this model’s sleek design integrates seamlessly into modern interiors while providing durable performance.

Both models feature advanced heating technologies, including electric resistance heating, which provides immediate warmth and evenly distributes heat throughout the space. The utilization of high-grade materials ensures durability, making these models resistant to wear and tear, prolonging their lifespan.

In terms of ease of installation, Empire Products has made these units user-friendly, ensuring that both models can be set up with minimal hassle, appealing to DIY enthusiasts as well as professional installers. The compact designs of the FAW-40-1SPP and FAW-40-1IP also offer flexibility in placement, allowing users to position them in areas where they are needed most without taking up excessive space.

In conclusion, Empire Products’ FAW-40-1SPP and FAW-40-1IP heaters exemplify the balance between utility and innovation. With their array of features, user-friendly controls, and advanced heating technologies, these models are perfect for those seeking reliable and efficient heating solutions in various settings. Whether for a cozy home environment or a bustling commercial space, these heaters stand out as prime examples of quality and performance in the industry.