Empire Products FAW-40-1SPP, FAW-40-1IP Qualified Installing Agency, Clearances

Page 5

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term "qualified agency" means any individual, firm, corporation or company which either in person or through a representative is engaged in and is responsible for (a) the installation or replacement of gas piping or (b) the connection, installation, repair or servicing of equipment, who is experienced in such work, familiar with all precautions required and has complied with all the requirements of the authority having jurisdiction.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54* Natural and Propane Installation Code, CSA B149.1.

*Available from the American National Standards Institute, Inc., 11 West 42nd St., New York, N.Y. 10036.

Clearances

1.In selecting a location forinstallation, it is necessary to provideadequate accessibility clearances for servicing and proper installation.

2.The FAW-40 can be attached to the wall or recessed into the wall up to 9 1/2 inches (24.1cm) in depth. Note: Do not place combustible header or material on top of unit when installed in wall. Maintain 3/4" minimum spacing above heater.

3.The wall in which the furnace is recessed has (0) zero (0mm) clearance to the furnace sides.

4.When using side discharge registers, SOR-1 or SOK-1, the furnace cannot be recessed into the wall.

5.Clearance to sidewall or combustible material is 4 inches (10.2cm).

6.Ceiling clearance is 4 inches (10.2cm).

7.Floor and rear wall clearance is (0) zero inches (0mm).

8.Clearance of 18 inches (46cm) is required to adjacent wall or combustible material when flush mounted SOR-1, side outlet register is used.

Before Installing Consider The Following Venting

1.A chimney for residential-type or low-heat gas utilization equipment shall extend at least 3 feet (914mm) above the highest point where it passes through a roof of a building and at least 2 feet (610mm) higher than any portion of building within a horizontal distance of 10 feet (3m).

2.This furnace must not be connected to a chimney flue serving a separate solid-fuel burning appliance.

3.Uninsulated Single-Wall Metal Pipe shall not be used outdoors in cold climates for venting gas utilization equipment.

4.Attention! This Fan Type Vented Wall Furnace is equipped with a vent safety switch. In the event of spillage of flue products due to improper venting the vent safety switch will open, which results in the main burners to "shut off".

Model No. FAW-40 may be vented as shown in Figure 4. The vent cap termination must be at least 12 feet (3.7m) above the floor and must exhaust to the outdoors.. Clearance to combustible construction is held by the fixed spacers at 1 inch (25mm) with B-1 or (B-W) vent pipe. Installation must conform to local codes.

A.4" (102mm) Round (all parts purchase locally except Item 2)

1.Type B-1 round pipe

2.Part No. DV-648, 4" (102mm) oval-to-round flue adapter kit (see accessories)

3.Single story type B-1 gas vents require a baseplate and one pair of ceiling plate spacers.

4.Multi-story type B-1 gas vents require a baseplate, one pair of ceiling plate spacers at the first floor ceiling and one pair of fire stop spacers at each successive ceiling level.

B.4" (102mm) Oval (all parts purchase locally)

1.Type B-1 oval pipe or B-W vent pipe

2.Single story type B-1 or (B-W) gas vents require a baseplate and one pair of ceiling plate spacers.

3.Multi-story type B-1 or (B-W) gas vents require a baseplate, one pair of ceiling plate spacers at the first floor ceiling and one pair of fire stop spacers at each successive ceiling level.

12427-4-0306

C.4" (102mm) Oval In-The-Wall (all parts purchase locally)

1.Type B-1 oval pipe or B-W vent pipe

2.Type B-1 oval elbows or B-W oval elbows

3.Single story type B-1 or (B-W) gas vents require a baseplate and one pair of ceiling plate spacers.

4.Multi-story type B-1 or (B-W) gas vents require a baseplate, one pair of ceiling plate spacers at the first floor ceiling and one pair of fire stop spacers at each successive ceiling level.

Stud space around gas vents must be free of obstructions and building paper.

4” ROUND

VENT

ENCLOSURE

ADAPTER

WALL

BASEPLATE

A.

SIDEFRONT

4” B-1 OVAL

BRACKET

BASEPLATE

B.

 

4” B-1 OVAL

4” 45 DEG.

 

OVAL ELBOWS

SPACER

 

BASEPLATE

C.

4” B-1 OVAL

SPACER

BASEPLATE

C.

Figure 4

Page 5

Image 5
Contents Installation Instructions Installation on Rugs and Tile Instructions to InstallerInstallation in Residential Garages 275 AccessoriesSafety Information for Users of LP-GAS Installation in a Confined Space Installation in an Unconfined SpaceVentilation and Combustion Air Ventilation Air Openings and DuctsBefore Installing Consider The Following Venting Qualified Installing AgencyClearances 102mm Oval In-The-Wall all parts purchase locallyInstalling Optional Rear Outlet Installing Optional Side OutletsInstalling a New Main Gas Cock Installation of Three-prong Grounding Plug AssemblyMethod of Installing a Tee Fitting Sediment Trap Pressure Testing of the Gas Supply SystemChecking Manifold Pressure Cleaning Combustion Exchanger AssemblyHigh Altitudes Piezo Pilot Ignitor InstructionsThermostat Installation WiringVent Safety Shutoff System Oiling the MotorIf Electrode Does Not Produce Spark Pilot Flame AdjustmentIf Pilot Does Not Light By Any Means If Pilot Does Not Remain On After Releasing KnobFor Your Safety Read Before Lighting For Your Safety Read Before Operating Sequence of Operation IP System Troubleshooting Sequence Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave Part number and description of part coincide12427-4-0306 Service Notes Empire Comfort Systems, Inc Instructions Pour L’INSTALLATION Manuel DU Propriétaire Installation sur un Tapis ou Tuile Instructions pour lInstallateurInstallation dans les Garages Residentiels Informations GénéralesInformation DE Sécurité Pour LES Utilisateurs DE Propane Installation dans un Espace Restreint Installation dans un Espace OuvertAir de Ventilation et de Combustion Ouvertures et Conduits pour l’Air de VentilationEspaces Libres Agence d’Installation QualifiéeInstallation d’une Sortie Arrière Optionnelle Installation des Sorties Optionnelles sur les CôtésEmplacement de lAlimentation de Gaz Emplacement du Radiateur Sur le MurEmplacement de lAlimentation Électrique Installation d’un Noveau Robinet PrincipalTest de Pression du Système dAlimentation de Gaz Aspect Convenable de la Flamme de la VeilleuseInstallation Électrique Aspect Convenable de la Flamme du Brûleur PrincipalInstallation du Thermostat Ne pas installer le thermostat sur un mur extérieurVeilleuse modèle fixe Appeler un technicien d’entretienSi l’électrode ne produit pas d’étincelle En aucune façon, la veilleuse ne s’allume pasAjustement de la flamme de la veilleuse Veilleuse modèle IPPour Votre Sécurité Lire Avant D’ALLUMER Instructions DE Fonctionnement 12427F-3-0903 12427F-3-0903 Façon de Commander les Pièces de Réparation Veilleuse ET SUP Port Pour LES Modé LES SPP Empire Comfort Systems, Inc

FAW-40-1IP, FAW-40-1SPP specifications

Empire Products has established itself as a leader in the manufacturing of high-quality heating solutions, and among its standout offerings are the FAW-40-1SPP and FAW-40-1IP models. These heaters have been engineered to meet the demands of various environments, providing efficient heating solutions while prioritizing user convenience and energy efficiency.

The FAW-40-1SPP is a powerful unit designed for versatile applications, whether in residential or commercial settings. This model boasts a robust output that ensures rapid heating even in larger spaces. Its advanced control system allows users to easily adjust the temperature settings, ensuring that comfort is maintained regardless of external weather conditions. This model is also equipped with safety features, including overheat protection, which automatically shuts off the heater if it reaches an unsafe temperature, a crucial feature for maintaining safety in populated areas.

On the other hand, the FAW-40-1IP represents innovation with its integrated programmable features. This unit is specifically designed for more tech-savvy users looking for convenience. The programmable thermostat enables users to set heating schedules, allowing for automated adjustments based on their daily routines. This not only enhances user comfort but also contributes to energy savings by avoiding unnecessary heating when spaces are unoccupied. Moreover, this model’s sleek design integrates seamlessly into modern interiors while providing durable performance.

Both models feature advanced heating technologies, including electric resistance heating, which provides immediate warmth and evenly distributes heat throughout the space. The utilization of high-grade materials ensures durability, making these models resistant to wear and tear, prolonging their lifespan.

In terms of ease of installation, Empire Products has made these units user-friendly, ensuring that both models can be set up with minimal hassle, appealing to DIY enthusiasts as well as professional installers. The compact designs of the FAW-40-1SPP and FAW-40-1IP also offer flexibility in placement, allowing users to position them in areas where they are needed most without taking up excessive space.

In conclusion, Empire Products’ FAW-40-1SPP and FAW-40-1IP heaters exemplify the balance between utility and innovation. With their array of features, user-friendly controls, and advanced heating technologies, these models are perfect for those seeking reliable and efficient heating solutions in various settings. Whether for a cozy home environment or a bustling commercial space, these heaters stand out as prime examples of quality and performance in the industry.