Empire Products FAW-40-1SPP, FAW-40-1IP Locating Furnace On Wall, Locating Gas Supply

Page 7
Page 7

#8 x 3/8" (9mm) screws provided.

8.Align clearance holes on 6" x 10" (152mm x 254mm) duct with screw holes on inner casing back and mark duct to be 2 1/4" (57mm) shorter than 8" x 12" (203mm x 305mm) boot. Remove duct and cut to proper length.

9.Attach 6" x 10" (152mm x 254mm) duct to inner casing back with

(4) #8 x 3/8" (9mm)screws removed in Step 3, 2 on top and 2 on bottom.

10.Insert rear register into 8" x 12" (203mm x 305mm) boot. Attach rear register to wall with (2) #10 x 1"(25mm) screws provided.

11.Installation of ROK-1 is completed.

Locating Furnace On Wall

The furnace is to be located on a wall. The furnace is 14 1/8" (35.9cm) in width and can be recessed into the wall with typical stud spacing.

A template is provided in furnace carton for locating gas line connection. Also, refer to Figure 7 for positioning the furnace on wall and for locating gas line connection.

Locating Gas Supply

The gas line can enter the furnace either through the floor or wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing. See Figure 7.

Figure 7

Locating Electric Supply

A 7/8" (22mm) diameter knockout is provided at the bottom of the left and right side panels. A three-prong (grounding) plug assembly is located within the control compartment (bottom) of the furnace. Please remove 7/8" (22mm) knockout from appropriate side panel when routing plug assembly to an electrical outlet.

Installation of Three-prong (Grounding) Plug Assembly

1.Disconnect nylon cap on 3' (914mm) plug assembly from nylon plug on wiring harness. Remove 3' (914mm) plug assembly from control compartment (bottom) of the furnace.

2.Remove 7/8" (22mm) knockout from appropriate side panel.

3.Insert nylon cap on 3' (914mm) plug assembly into the 7/8" (22mm) hole in the side panel.

4.Connect nylon cap on 3' (914mm) plug assembly to nylon plug on the wiring harness.

5.Place 7/8" (22mm) strain relief bushing around the cord of the 3'

12427-4-0306

(914mm) plug assembly. Insert 7/8" (22mm) strain relief bushing into the 7/8" (22mm) hole in the side panel.

Attention! The 7/8" (22mm) strain relief bushing is located within the same yellow envelope as the Installation Instructions and Owner's Manual.

Attaching Furnace to Wall

When attaching furnace to the wall remove that portion of baseboard and molding on the wall which is behind the furnace. Attach furnace to wall, at the outer casing top, with (2) toggle bolts provided and to floor, at the outer casing bottom, with (2) #10 x 1 1/2" (38mm) screws provided.

Gas Supply

Check all local codes for requirements, especially for the size and type of gas supply line required. On Natural gas lines less than 75' (22.9m) long, use 1/2" (13mm) pipe; on longer runs, use 3/4" (19mm) iron pipe or equal. On LP gas lines please consult LP gas supplier.

Installing a New Main Gas Cock

Each appliance should have its own manual gas cock.

A manual main gas cock should be located in the vicinity of the unit. Where none exists, or where its size or location is not adequate, contact your local authorized installer for installation or relocation.

Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied petroleum gases. The gas lines must be checked for leaks by the installer. This should be done with a soap solution watching for bubbles on all exposed connections, and if unexposed, a pressure test should be made.

Never use an exposed flame to check for leaks. Appliance must be disconnected from piping at inlet of control valve and pipe capped or plugged for pressure test. Never pressure test with appliance connected; control valve will sustain damage!

A gas valve and ground joint union should be installed in the gas line upstream of the gas control to aid in servicing. It is required by the National Fuel Gas Code that a drip line be installed near the gas inlet. This should consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles may collect.

Figure 8

Method of Installing a Tee Fitting Sediment Trap

The use of the following gas connectors is recommended:

ANS Z21.24 Appliance Connectors of Corrugated Metal Tubing and Fittings

ANS Z21.45 Assembled Flexible Appliance Connectors of Other Than All-Metal Construction

The above connectors may be used if acceptable by the authority having jurisdiction.

Pressure Testing of the Gas Supply System

1.To check the inlet pressure to the gas valve, a 1/8" (3mm) N.P.T. plugged tapping, accessible for test gauge connection, must be placed immediately upstream of the gas supply connection to the appliance.

2.The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

3.The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

Image 7
Contents Installation Instructions 275 Accessories Instructions to InstallerInstallation on Rugs and Tile Installation in Residential GaragesSafety Information for Users of LP-GAS Ventilation Air Openings and Ducts Installation in an Unconfined SpaceInstallation in a Confined Space Ventilation and Combustion Air102mm Oval In-The-Wall all parts purchase locally Qualified Installing AgencyBefore Installing Consider The Following Venting ClearancesInstalling Optional Rear Outlet Installing Optional Side OutletsPressure Testing of the Gas Supply System Installation of Three-prong Grounding Plug AssemblyInstalling a New Main Gas Cock Method of Installing a Tee Fitting Sediment TrapPiezo Pilot Ignitor Instructions Cleaning Combustion Exchanger AssemblyChecking Manifold Pressure High AltitudesOiling the Motor WiringThermostat Installation Vent Safety Shutoff SystemIf Pilot Does Not Remain On After Releasing Knob Pilot Flame AdjustmentIf Electrode Does Not Produce Spark If Pilot Does Not Light By Any MeansFor Your Safety Read Before Lighting For Your Safety Read Before Operating Sequence of Operation IP System Troubleshooting Sequence Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave Part number and description of part coincide12427-4-0306 Service Notes Empire Comfort Systems, Inc Instructions Pour L’INSTALLATION Manuel DU Propriétaire Informations Générales Instructions pour lInstallateurInstallation sur un Tapis ou Tuile Installation dans les Garages ResidentielsInformation DE Sécurité Pour LES Utilisateurs DE Propane Ouvertures et Conduits pour l’Air de Ventilation Installation dans un Espace OuvertInstallation dans un Espace Restreint Air de Ventilation et de CombustionEspaces Libres Agence d’Installation QualifiéeInstallation d’une Sortie Arrière Optionnelle Installation des Sorties Optionnelles sur les CôtésInstallation d’un Noveau Robinet Principal Emplacement du Radiateur Sur le MurEmplacement de lAlimentation de Gaz Emplacement de lAlimentation ÉlectriqueTest de Pression du Système dAlimentation de Gaz Aspect Convenable de la Flamme de la VeilleuseNe pas installer le thermostat sur un mur extérieur Aspect Convenable de la Flamme du Brûleur PrincipalInstallation Électrique Installation du ThermostatEn aucune façon, la veilleuse ne s’allume pas Appeler un technicien d’entretienVeilleuse modèle fixe Si l’électrode ne produit pas d’étincelleAjustement de la flamme de la veilleuse Veilleuse modèle IPPour Votre Sécurité Lire Avant D’ALLUMER Instructions DE Fonctionnement 12427F-3-0903 12427F-3-0903 Façon de Commander les Pièces de Réparation Veilleuse ET SUP Port Pour LES Modé LES SPP Empire Comfort Systems, Inc

FAW-40-1IP, FAW-40-1SPP specifications

Empire Products has established itself as a leader in the manufacturing of high-quality heating solutions, and among its standout offerings are the FAW-40-1SPP and FAW-40-1IP models. These heaters have been engineered to meet the demands of various environments, providing efficient heating solutions while prioritizing user convenience and energy efficiency.

The FAW-40-1SPP is a powerful unit designed for versatile applications, whether in residential or commercial settings. This model boasts a robust output that ensures rapid heating even in larger spaces. Its advanced control system allows users to easily adjust the temperature settings, ensuring that comfort is maintained regardless of external weather conditions. This model is also equipped with safety features, including overheat protection, which automatically shuts off the heater if it reaches an unsafe temperature, a crucial feature for maintaining safety in populated areas.

On the other hand, the FAW-40-1IP represents innovation with its integrated programmable features. This unit is specifically designed for more tech-savvy users looking for convenience. The programmable thermostat enables users to set heating schedules, allowing for automated adjustments based on their daily routines. This not only enhances user comfort but also contributes to energy savings by avoiding unnecessary heating when spaces are unoccupied. Moreover, this model’s sleek design integrates seamlessly into modern interiors while providing durable performance.

Both models feature advanced heating technologies, including electric resistance heating, which provides immediate warmth and evenly distributes heat throughout the space. The utilization of high-grade materials ensures durability, making these models resistant to wear and tear, prolonging their lifespan.

In terms of ease of installation, Empire Products has made these units user-friendly, ensuring that both models can be set up with minimal hassle, appealing to DIY enthusiasts as well as professional installers. The compact designs of the FAW-40-1SPP and FAW-40-1IP also offer flexibility in placement, allowing users to position them in areas where they are needed most without taking up excessive space.

In conclusion, Empire Products’ FAW-40-1SPP and FAW-40-1IP heaters exemplify the balance between utility and innovation. With their array of features, user-friendly controls, and advanced heating technologies, these models are perfect for those seeking reliable and efficient heating solutions in various settings. Whether for a cozy home environment or a bustling commercial space, these heaters stand out as prime examples of quality and performance in the industry.