Empire Products FAW-40-1IP Checking Manifold Pressure, High Altitudes, Proper Pilot Flame

Page 8

Attention! If one of the above procedures results in pressures in excess of 1/2 psig (14" w.c.) (3.5 kPa) on the appliance gas valve, it will result in a hazardous condition.

Checking Manifold Pressure

Both Propane and Natural gas valves have a built-in pressure regulator in the gas valve. Natural gas models will have a manifold pressure of approximately 4.0" w.c. (.996kPa) at the valve outlet with the inlet pressure to the valve from a minimum of 5.0" w.c. (1.24kPa) for the purpose of input adjustment to a maximum of 10.5" w.c. (2.615kPa). Propane gas models will have a manifold pressure approximately 10.0" w.c. (2.49kPa) at the valve outlet with the inlet pressure to the valve from a minimum of 11.0" w.c. (2.739kPa) for the purpose of input adjustment to a maximum of 13.0" w.c. (3.237kPa).

A1/8" (3mm) N.P.T. plugged tapping, accessible for test gauge connection, is located on the outlet side of the gas control.

The built-in regulator comes on at approximately 1/4th pressure and full on in 10 seconds.

Figure 9

High Altitudes

For altitudes/elevations above 2,000 feet (610m), input ratings should be reduced at the rate of 4 percent for each 1,000 feet (305m) above sea level. For Canadian high altitude applications, this appliance is suitable for installation at elevations between 0 feet (0m) and 4,500 feet (1,372m) without change.

Piezo Pilot Ignitor Instructions

Depressing the red button completely causes a spark to occur at the pilot. This is a substitute for a match which requires opening the pilot hole cover.

To light the pilot, it is important that the electrode be 1/8" (3mm) from the thermocouple. The spark must occur at the point the burner flame hits the thermocouple. The end of the electrode will be red hot with the pilot on.

On a new installation with air in the gas line, it is suggested that a match be used. The match will light the pilot faster than the piezo under this condition.

Proper Pilot Flame

The correct pilot flame (Figure 10) will be blue, extending past the thermocouple. The flame will surround the thermocouple just below the tip.

Natural gas pilots require adjusting when the inlet gas pressure is above 5" w.c. (1.245kPa). Remove the pilot cover screw on the control valve (Figure 9), and turn the adjustment screw clockwise to reduce flame. Replace pilot cover screw to eliminate gas leakage.

LP gas (propane) will not require adjustment.

After use, cleaning may be required for the proper flame.

Proper Main Burner Flame

The correct flame will be a short, blue inner flame with a much larger, light blue, outer flame. The burner does not have a primary air adjustment. The flame will be correct if the factory-set pressure and orifice opening are used. After the furnace has been operating, the burner ports may be blocked by foreign matter carried in by combustion air. Therefore, cleaning of the burner may be needed for proper flame.

To clean burner port disconnect the gas supply to the valve, and remove the screws fastening the burner door. After removing the burner door

Page 8

from the burner box, remove each main burner. Pilot mounting bracket will need to be unscrewed and moved out of the way to remove all burners. Burners can be blown out using compressed air or by blowing through them. Be sure there is no lint or foreign debris blocking the burner ports. Reassemble using the same screws earlier removed and locate pilot in the same position as before and noted above.

Figure 10

Figure 11

Cleaning Combustion (Exchanger) Assembly

A QUALIFIED SERVICE PERSON should remove the combustion (exchanger) assembly and flue baffles. Apply air pressure to the inside of the combustion (exchanger) assembly and flue baffles in order to clear all passageways.

12427-4-0306

Image 8
Contents Installation Instructions Instructions to Installer Installation on Rugs and TileInstallation in Residential Garages 275 AccessoriesSafety Information for Users of LP-GAS Installation in an Unconfined Space Installation in a Confined SpaceVentilation and Combustion Air Ventilation Air Openings and DuctsQualified Installing Agency Before Installing Consider The Following VentingClearances 102mm Oval In-The-Wall all parts purchase locallyInstalling Optional Side Outlets Installing Optional Rear OutletInstallation of Three-prong Grounding Plug Assembly Installing a New Main Gas CockMethod of Installing a Tee Fitting Sediment Trap Pressure Testing of the Gas Supply SystemCleaning Combustion Exchanger Assembly Checking Manifold PressureHigh Altitudes Piezo Pilot Ignitor InstructionsWiring Thermostat InstallationVent Safety Shutoff System Oiling the MotorPilot Flame Adjustment If Electrode Does Not Produce SparkIf Pilot Does Not Light By Any Means If Pilot Does Not Remain On After Releasing KnobFor Your Safety Read Before Lighting For Your Safety Read Before Operating Sequence of Operation IP System Troubleshooting Sequence Part number and description of part coincide Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave12427-4-0306 Service Notes Empire Comfort Systems, Inc Instructions Pour L’INSTALLATION Manuel DU Propriétaire Instructions pour lInstallateur Installation sur un Tapis ou TuileInstallation dans les Garages Residentiels Informations GénéralesInformation DE Sécurité Pour LES Utilisateurs DE Propane Installation dans un Espace Ouvert Installation dans un Espace RestreintAir de Ventilation et de Combustion Ouvertures et Conduits pour l’Air de VentilationAgence d’Installation Qualifiée Espaces LibresInstallation des Sorties Optionnelles sur les Côtés Installation d’une Sortie Arrière OptionnelleEmplacement du Radiateur Sur le Mur Emplacement de lAlimentation de GazEmplacement de lAlimentation Électrique Installation d’un Noveau Robinet PrincipalAspect Convenable de la Flamme de la Veilleuse Test de Pression du Système dAlimentation de GazAspect Convenable de la Flamme du Brûleur Principal Installation ÉlectriqueInstallation du Thermostat Ne pas installer le thermostat sur un mur extérieurAppeler un technicien d’entretien Veilleuse modèle fixeSi l’électrode ne produit pas d’étincelle En aucune façon, la veilleuse ne s’allume pasVeilleuse modèle IP Ajustement de la flamme de la veilleusePour Votre Sécurité Lire Avant D’ALLUMER Instructions DE Fonctionnement 12427F-3-0903 12427F-3-0903 Façon de Commander les Pièces de Réparation Veilleuse ET SUP Port Pour LES Modé LES SPP Empire Comfort Systems, Inc

FAW-40-1IP, FAW-40-1SPP specifications

Empire Products has established itself as a leader in the manufacturing of high-quality heating solutions, and among its standout offerings are the FAW-40-1SPP and FAW-40-1IP models. These heaters have been engineered to meet the demands of various environments, providing efficient heating solutions while prioritizing user convenience and energy efficiency.

The FAW-40-1SPP is a powerful unit designed for versatile applications, whether in residential or commercial settings. This model boasts a robust output that ensures rapid heating even in larger spaces. Its advanced control system allows users to easily adjust the temperature settings, ensuring that comfort is maintained regardless of external weather conditions. This model is also equipped with safety features, including overheat protection, which automatically shuts off the heater if it reaches an unsafe temperature, a crucial feature for maintaining safety in populated areas.

On the other hand, the FAW-40-1IP represents innovation with its integrated programmable features. This unit is specifically designed for more tech-savvy users looking for convenience. The programmable thermostat enables users to set heating schedules, allowing for automated adjustments based on their daily routines. This not only enhances user comfort but also contributes to energy savings by avoiding unnecessary heating when spaces are unoccupied. Moreover, this model’s sleek design integrates seamlessly into modern interiors while providing durable performance.

Both models feature advanced heating technologies, including electric resistance heating, which provides immediate warmth and evenly distributes heat throughout the space. The utilization of high-grade materials ensures durability, making these models resistant to wear and tear, prolonging their lifespan.

In terms of ease of installation, Empire Products has made these units user-friendly, ensuring that both models can be set up with minimal hassle, appealing to DIY enthusiasts as well as professional installers. The compact designs of the FAW-40-1SPP and FAW-40-1IP also offer flexibility in placement, allowing users to position them in areas where they are needed most without taking up excessive space.

In conclusion, Empire Products’ FAW-40-1SPP and FAW-40-1IP heaters exemplify the balance between utility and innovation. With their array of features, user-friendly controls, and advanced heating technologies, these models are perfect for those seeking reliable and efficient heating solutions in various settings. Whether for a cozy home environment or a bustling commercial space, these heaters stand out as prime examples of quality and performance in the industry.