Allied Air Enterprises A95UH, 95G1UH, A93UH, 92G1UH Planned Service, Failure Codes

Page 44

PLANNED SERVICE

A service technician should check the following items during an annual inspection. Power to the unit must be shut off for safety.

Fresh air grilles and louvers (on the unit and in the room where the furnace is installed) - Must be open and unobstructed to provide combustion air.

Burners - Must be inspected for rust, dirt, or signs of water.

Vent pipe - Must be inspected for signs of water, cracked, damaged or sagging pipe, or disconnected joints.

Unit appearance - Must be inspected for rust, dirt, signs of water, burnt or damaged wires, or components.

Blower access door - Must be properly in place and provide a seal between the return air and the room where the furnace

is installed.

Return air duct - Must be properly attached and provide an air seal to the unit.

Operating performance - Unit must be observed during operation to monitor proper performance of the unit and the vent system.

Combustion gases - Flue products should be analyzed and compared to the unit specifications.

Problems detected during the inspection may make it necessary to temporarily shut down the furnace until the items can be repaired or replaced.

Instruct the homeowners to pay attention to their furnace. Situations can arise between annual furnace inspections that may result in unsafe operation. For instance, items innocently stored next to the furnace may obstruct the combustion air supply. This could cause incomplete combustion and the production of carbon monoxide gas.

FAILURE CODES

Page 44 of 48

Issue 1031

506501-01

Image 44
Contents Table of Contents A95UH, A93UH, 95G1UH & 92G1UHA95UH, A93UH, 95G1UH & 92G1UH Unit Dimensions inches mm Front View Side ViewExpanded View Safety Information A95UH, A93UH, 95G1UH &92G1UH Gas FurnaceShipping and Packing List Building CodesUse of Furnace as a Construction Heater Installed LocationsInstalled in Combination with a Cooling Coil Product Contains Fiberglass Wool Combustion, Dilution & Ventilation AirUnconfined Space Confined SpaceAir from Inside Equipment in Confined Space All Air From InsideAir from Outside Installation Setting EquipmentShipping Bolt Removal Upflow ApplicationsSide Return Air With transition and filter Installation ClearancesReturn Air Guidlines Horizontal Applications Optional Return Air Base Upflow Applications OnlyRemoving the Bottom Panel Horizontal Application Installation Clearances Suspended Installation of Horizontal UnitPipe & Fittings Specifications Return Air -- Horizontal ApplicationsFilters Duct SystemPiping and Fittings Specifications Canadian Applications OnlyJoint Cementing Procedure Outdoor Termination Kits UsageExhaust Piping Figures 22 Minimum Vent Pipe Lengths Exhaust PipeHorizontal Application Maximum Allowable Vent Length Right Hand Discharge Shown Intake Piping Figures 24 through Typical AIR Intake Pipe Connections For Canadian Installations Only General Guidelines for Vent TerminationsFor NON-DIRECT Vent INSTALLATiONS in the USA and Canada Vent Termination ClearancesFor Direct Vent INSTALLATiONS in the USA and Canada 15F75 or 44J41 Field Supplied Wall TerminationDirect Vent Concentric Rooftop Termination Direct Vent Application Using Existing Chimney NON-DIRECT Vent Application Using Existing Chimney NON-DIRECT Vent Roof Termination KITNON-DIRECT Vent Field Supplied Wall Termination Condensate PipingCondensate Trap and Plug Locations Unit shown in upflow positionCondensate Trap Locations Unit shown in upflow position with remote trapFire or Explosion Hazard Gas PipingLeak Check Horizontal Applications Possible Gas Piping Configurations Carbon Monoxide Poisoning Hazard Precautions and Procedures Interior MAKE-UP BOX InstallationAccessory Terminals ElectricalTypical Field Wiring Diagram Furnace & Condensing Unit Thermostat DesignationsIndoor Blower Speeds Generator Use Voltage RequirementsTypical Wiring Diagram Placing the furnace into operation Integrated ControlAutomatic Hot Surface Ignition System Unit Start-Up GAS Valve Shown in on Position Gas Pressure Adjustment Supply Pressure MeasurementManifold Pressure Measurement High Altitude InformationCarbon Monoxide Poisoning Hazard Heat FAN-OFF Time Seconds Electrical SHOCK, Fire Or Explosion Hazard Cleaning the Burner Assembly Planned Service Failure CodesRepair Parts List Cabinet Parts Heating PartsControl Panel Parts Blower PartsUnit SET UP Unit Operation BELOW. Keep Clear of ALL Obstructions Manufacturer Requirements

92G1UH, 95G1UH, A95UH, A93UH specifications

Allied Air Enterprises is renowned for producing high-quality HVAC systems, and its models A93UH, 92G1UH, A95UH, and 95G1UH are no exception. These units exemplify cutting-edge technology, efficiency, and reliability, making them popular choices for residential and commercial applications.

The A93UH model is a high-efficiency gas furnace designed with advanced features that maximize performance while maintaining low operating costs. It boasts a 93% Annual Fuel Utilization Efficiency (AFUE) rating, which ensures that a significant portion of the fuel consumed translates into heat. The A93UH incorporates variable-speed blower technology, allowing for precise airflow adjustments that enhance comfort and energy savings.

Similarly, the 92G1UH is built to provide exceptional heating capabilities. With a robust construction and innovative design, this model also achieves a 92% AFUE rating. It features a durable heat exchanger and a reliable ignition system that ensures consistent performance. The 92G1UH is engineered for quiet operation, minimizing noise levels and contributing to a more comfortable indoor environment.

Moving on to the A95UH, this unit represents the pinnacle of efficiency with its impressive 95% AFUE rating. This model not only emphasizes energy savings but also focuses on long-term durability. Equipped with a two-stage gas valve, the A95UH allows for flexible heating based on demand, which translates into enhanced comfort and efficiency. Additionally, the integrated SmartComfort technology provides homeowners with user-friendly control options.

The 95G1UH model shares many of the same advanced features as the A95UH but is tailored for different installation scenarios. With a comparable efficiency rating, the 95G1UH emphasizes ease of maintenance and installation. Its compact design and lightweight construction make it an ideal choice for various settings where space is limited.

All four models incorporate the latest in comfort control technology, allowing for seamless connectivity and programmability. Homeowners can utilize smart thermostats to optimize their heating schedules, further enhancing energy savings. The featured robust warranty and service support from Allied Air Enterprises provide peace of mind, ensuring that these units will deliver reliable performance for years to come.

Overall, the A93UH, 92G1UH, A95UH, and 95G1UH models stand out in the HVAC market due to their efficiency, innovative features, and durability. These units cater to a variety of heating needs while keeping operational costs low, making them wise investments for any property owner.