Allied Air Enterprises A95UH, A93UH, 95G1UH &92G1UH Gas Furnace, Shipping and Packing List

Page 4

A95UH, A93UH, 95G1UH &92G1UH Gas Furnace

The A95UH/A93UH/95G1UH & 92G1UH Category IV gas furnace is shipped ready for installation in the upflow or horizontal position. The furnace is shipped with the bottom panel in place. The bottom panel must be removed if the unit is to be installed in horizontal or upflow applications with bottom return air.

The A95UH/A93UH/95G1UH & 92G1UH can be installed as either a Direct Vent or a Non-Direct Vent gas central furnace

The furnace is equipped for installation in natural gas applications. A conversion kit (ordered separately) is required for use in propane/LP gas applications.

NOTE: In Direct Vent installations, combustion air is taken from outdoors and flue gases are discharged outdoors. In Non-Direct Vent installations, combustion air is taken from indoors and flue gases are discharged outdoors. See Figure 2 for applications involving roof termination.

Figure 2

Shipping and Packing List

1 - Assembled Gas Furnace

1 - Bag assembly containing the following:

3 - Wire nuts

1 - Snap bushing

1 - Snap Plug

1 - Wire tie

1 - Condensate trap

1 - Condensate trap cap

1 - Condensate trap clamp

1 - 2” diameter debris screen

Check equipment for shipping damage. If you find any damage, immediately contact the last carrier.

Please refer to specification sheets for available accessories.

Safety Information

WARNING

Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Installation and service must be performed by a licensed professional installer (or equivalent), service agency or the gas supplier.

CAUTION

As with any mechanical equipment, personal injury can result from contact with sharp sheet metal edges. Be careful when you handle this equipment.

DANGER

DANGER OF EXPLOSION!

There are circumstances in which odorant used with LP/ Propane gas can lose its scent. In case of a leak, LP/ Propane gas will settle close to the floor and may be difficult to smell. An LP/Propane leak detector should be installed in all LP applications.

Use only the type of gas approved for use with this furnace. Refer to unit nameplate.

A95UH/A93UH/95G1UH & 92G1UH units are CSA International certified to ANSI Z21.47 and CSA 2.3 standards.

Building Codes

In the USA, installation of gas furnaces must conform with local building codes. In the absence of local codes, units must be installed according to the current National Fuel Gas Code (ANSI Z223.1/NFPA 54). The National Fuel Gas Code is available from the American National Standards Institute, Inc., 11 West 42nd Street, New Your, NY 10036.

In Canada, installation must conform with current National Standard of Canada CSA-B149 Natural Gas and Propane Installation Codes, local plumbing or waste water codes and other applicable local codes.

In order to ensure proper unit operation in non-direct vent applications, combustion and ventilation air supply must be provided according to the current National Fuel Gas Code or CSA-B149 standard.

Page 4 of 48

Issue 1031

506501-01

Image 4
Contents Table of Contents A95UH, A93UH, 95G1UH & 92G1UHA95UH, A93UH, 95G1UH & 92G1UH Unit Dimensions inches mm Front View Side ViewExpanded View Safety Information A95UH, A93UH, 95G1UH &92G1UH Gas FurnaceShipping and Packing List Building CodesInstalled in Combination with a Cooling Coil Installed LocationsUse of Furnace as a Construction Heater Product Contains Fiberglass Wool Combustion, Dilution & Ventilation AirUnconfined Space Confined SpaceAir from Inside Equipment in Confined Space All Air From InsideAir from Outside Installation Setting EquipmentShipping Bolt Removal Upflow ApplicationsReturn Air Guidlines Installation ClearancesSide Return Air With transition and filter Removing the Bottom Panel Optional Return Air Base Upflow Applications OnlyHorizontal Applications Horizontal Application Installation Clearances Suspended Installation of Horizontal UnitPipe & Fittings Specifications Return Air -- Horizontal ApplicationsFilters Duct SystemPiping and Fittings Specifications Canadian Applications OnlyJoint Cementing Procedure Outdoor Termination Kits UsageExhaust Piping Figures 22 Horizontal Application Exhaust PipeMinimum Vent Pipe Lengths Maximum Allowable Vent Length Right Hand Discharge Shown Intake Piping Figures 24 through Typical AIR Intake Pipe Connections For Canadian Installations Only General Guidelines for Vent TerminationsFor NON-DIRECT Vent INSTALLATiONS in the USA and Canada Vent Termination ClearancesFor Direct Vent INSTALLATiONS in the USA and Canada 15F75 or 44J41 Field Supplied Wall TerminationDirect Vent Concentric Rooftop Termination Direct Vent Application Using Existing Chimney NON-DIRECT Vent Application Using Existing Chimney NON-DIRECT Vent Roof Termination KITNON-DIRECT Vent Field Supplied Wall Termination Condensate PipingCondensate Trap and Plug Locations Unit shown in upflow positionCondensate Trap Locations Unit shown in upflow position with remote trapLeak Check Gas PipingFire or Explosion Hazard Horizontal Applications Possible Gas Piping Configurations Carbon Monoxide Poisoning Hazard Precautions and Procedures Interior MAKE-UP BOX InstallationAccessory Terminals ElectricalTypical Field Wiring Diagram Furnace & Condensing Unit Thermostat DesignationsIndoor Blower Speeds Generator Use Voltage RequirementsTypical Wiring Diagram Automatic Hot Surface Ignition System Unit Start-Up Integrated ControlPlacing the furnace into operation GAS Valve Shown in on Position Gas Pressure Adjustment Supply Pressure MeasurementManifold Pressure Measurement High Altitude InformationCarbon Monoxide Poisoning Hazard Heat FAN-OFF Time Seconds Electrical SHOCK, Fire Or Explosion Hazard Cleaning the Burner Assembly Planned Service Failure CodesRepair Parts List Cabinet Parts Heating PartsControl Panel Parts Blower PartsUnit SET UP Unit Operation BELOW. Keep Clear of ALL Obstructions Manufacturer Requirements

92G1UH, 95G1UH, A95UH, A93UH specifications

Allied Air Enterprises is renowned for producing high-quality HVAC systems, and its models A93UH, 92G1UH, A95UH, and 95G1UH are no exception. These units exemplify cutting-edge technology, efficiency, and reliability, making them popular choices for residential and commercial applications.

The A93UH model is a high-efficiency gas furnace designed with advanced features that maximize performance while maintaining low operating costs. It boasts a 93% Annual Fuel Utilization Efficiency (AFUE) rating, which ensures that a significant portion of the fuel consumed translates into heat. The A93UH incorporates variable-speed blower technology, allowing for precise airflow adjustments that enhance comfort and energy savings.

Similarly, the 92G1UH is built to provide exceptional heating capabilities. With a robust construction and innovative design, this model also achieves a 92% AFUE rating. It features a durable heat exchanger and a reliable ignition system that ensures consistent performance. The 92G1UH is engineered for quiet operation, minimizing noise levels and contributing to a more comfortable indoor environment.

Moving on to the A95UH, this unit represents the pinnacle of efficiency with its impressive 95% AFUE rating. This model not only emphasizes energy savings but also focuses on long-term durability. Equipped with a two-stage gas valve, the A95UH allows for flexible heating based on demand, which translates into enhanced comfort and efficiency. Additionally, the integrated SmartComfort technology provides homeowners with user-friendly control options.

The 95G1UH model shares many of the same advanced features as the A95UH but is tailored for different installation scenarios. With a comparable efficiency rating, the 95G1UH emphasizes ease of maintenance and installation. Its compact design and lightweight construction make it an ideal choice for various settings where space is limited.

All four models incorporate the latest in comfort control technology, allowing for seamless connectivity and programmability. Homeowners can utilize smart thermostats to optimize their heating schedules, further enhancing energy savings. The featured robust warranty and service support from Allied Air Enterprises provide peace of mind, ensuring that these units will deliver reliable performance for years to come.

Overall, the A93UH, 92G1UH, A95UH, and 95G1UH models stand out in the HVAC market due to their efficiency, innovative features, and durability. These units cater to a variety of heating needs while keeping operational costs low, making them wise investments for any property owner.