Empire Products DVC-35IPT-1, DVC-35T-1 DVC-35T Standing Pilot Lighting Instructions

Page 12

DVC-35T STANDING PILOT LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch;

do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat to lowest setting.

3.Turn off all electric power to the appliance.

4.Remove control access panel (lower front panel).

5.Turn gas control knob clockwise to “OFF.”

6.Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step.

7.Remove the pilot ac- cess cover located on the combustion cham- ber.

8.Find pilot - follow metal tube from gas

control. The pilot is located between the two burner tubes behind the pilot access cover.

9. Turn gas control knob counterclockwise to “PILOT.”

10.Push and hold red reset button down completely and repeatedly push the ignitor button until the pilot burner is lit. Pilot may also be lit with a match. Continue to hold the red reset button down for about one (1) minute after the pilot is lit. Release button and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 10.

• If button does not pop up when released, stop and immediately call a qualified service technician or gas supplier.

• If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.

11.Replace pilot access cover.

12.Turn gas control knob counterclockwise to “ON.”

13.Replace control access panel (lower front panel).

14.Turn on all electric power to the appliance.

15.Set thermostat to desired setting.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to lowest setting.

2.Turn off all electric power to appliance if service is to be performed .

3.Remove control access panel (lower front panel).

4.Push in gas control knob slightly and turn clockwise to “OFF.” Do not force.

5.Replace control access panel (lower front panel).

Page 12

13119-6-0107

Image 12
Contents Installation Instructions Table of Contents Important Safety Information Vent KIT InformationSafety Information for Users of LP-GAS Learn to recognize the odor of LP-gas. Your local LP-GasHave any question about the gas odor, call your LP-gas Measure under any conditionRequirements for Massachusetts Clear of ALL ObstructionsSpecifications IntroductionInstalling a New Main Gas Cock GAS SupplyLocating Gas Supply Recommended Gas Pipe DiameterClearances Checking Manifold PressureClearances Installation Instructions Installing Optional Side OutletsLocating Wall Opening Installation of Three-prong Grounding Plug Assembly Using Plastic Expansion AnchorsLocating Electric Supply Attaching Furnace to WallInstalling Vent Assembly Reassembly And Resealing Vent-Air Intake SystemFor Your Safety Read Before Lighting DVC-35T Standing Pilot Lighting InstructionsFor Your Safety Read Before Operating Pilot Flame Characteristics Pilot Flame AdjustmentIP-Model Pilot Main Burner Flame Characteristics WiringThermostat Installation DVC-35TLadder Wiring DIAGRAM-IP Valve Service and Maintenance Suggestions DVC-35IPT Intermittent Pilot Sequence of Operation DVC-35IPT Intermittent Pilot System Troubleshooting Sequence HOW to Order Repair Parts Parts ListParts View Service Notes Service Notes 13119-6-0107

DVC-35T-1, DVC-35IPT-1 specifications

Empire Products has long been recognized for its commitment to delivering high-quality heating solutions, and two notable offerings are the DVC-35T-1 and DVC-35IPT-1 gas-burning direct vent fireplaces. These units are designed to provide both comfort and aesthetic appeal, making them excellent choices for any home environment.

The DVC-35T-1 model boasts a classic design, paired with modern efficiency. With a heat output of 35,000 BTUs, it effectively warms spaces up to 1,100 square feet, ensuring even heat distribution throughout the room. One of the standout features is its advanced venting system, which allows for horizontal or vertical venting options, making it versatile for different installation layouts. The DVC-35T-1 also comes equipped with an adjustable flame control, enabling users to customize the ambiance to their preference. Its glass viewing area enhances the overall aesthetic while providing a full view of the flames.

On the other hand, the DVC-35IPT-1 model features an innovative design that incorporates a premium fireplace insert. This unit is specifically engineered to fit into existing fireplaces, transforming traditional wood-burning setups into efficient gas-burning heating sources. Like its counterpart, the DVC-35IPT-1 offers a maximum heat output of 35,000 BTUs, providing substantial warmth tailored for spaces up to 1,100 square feet. It is equipped with a state-of-the-art electronic ignition system, which ensures reliable and easy starts every time. The unit also includes a decorative log set that adds to its realism and charm, allowing for a cozy, inviting atmosphere.

Both models prioritize efficiency, with an impressive thermal efficiency rating, which not only helps in reducing heating costs but also makes them environmentally friendly options. The incorporation of a sealed combustion system ensures that indoor air quality is maintained, as it draws outside air for combustion and expels exhaust gases outdoors.

In addition to their technical features, the DVC-35T-1 and DVC-35IPT-1 are designed with user convenience in mind. Remote control capabilities allow for effortless operation, while easy maintenance ensures that homeowners spend less time worrying about upkeep and more time enjoying their fireplaces.

Overall, the Empire Products DVC-35T-1 and DVC-35IPT-1 fireplaces represent a blend of efficiency, technology, and aesthetic appeal, making them ideal options for those looking to enhance their home environment with reliable and stylish heating solutions.