Attention: DO NOT attempt to cut vent tubes. When you order appropriate vent kit for measured wall depth the vent tubes will fit together.

1.Place provided caulking beneath the collar of the outside mounting plate. Use additional caulking to correct uneven wall surface, such as clapboard.

2.Insert six inch air tube on outside mounting plate INTO six inch air tube attached to air drop. Place four inch flue tube on vent cap OVER four inch flue tube attached to outlet box. Position the outside mounting plate so that six inch air tube has a slight downward slope to the outside. The downward slope is necessary to prevent the entry of rainwater. Attach outside mounting plate to exterior wall with four (4) 10 x 1 1/2” screws.

3.Installation is completed.

Reassembly And Resealing Vent-Air Intake System

When vent-air intake system is removed for servicing the furnace, the following steps will assure proper reassembly and resealing of the vent-air intake assembly.

1.Remove old caulking beneath the collar of the outside mounting plate. Apply new caulking beneath the collar of the outside mounting plate. Use additional caulking to correct uneven wall surface, such as clapboard.

2.Insert six inch air tube on outside mounting plate INTO six inch air tube attached to air drop. Position the outside mounting plate so that six inch air tube has a slight downward slope to the outside. The downward slope is necessary to prevent the entry of rainwater. Attach outside mounting plate to exterior wall with four (4) 10 x 1 1/2” screws.

3.Place four inch flue tube on vent cap OVER four inch flue tube attached to outlet box.Attach vent cap to outside mounting plate with three (3) 10 x 1/2” screws.

4.Reassembly and resealing vent-air intake system is completed.

Installing a Vent Near a Window Ledge,

Other Type of Projection or on Siding (vinyl, aluminum, etc.) Direct vent furnaces are designed to be installed on a uniform outside wall. When the wind comes from any angle (up, down or from either side), it must hit the vent cap equally over both the air inlet and the flue outlet portions of the vent. Any wall projection, such as a door or window casing, which disturbs the wind on one side of the air inlet section will result in back pressure on the flue section smothering the flame and eventual pilot outage.

When the vent cap is to be installed on siding or it appears that a projection within 6” of any side of the air inlet section could shield the air inlet section, the entire vent should be supported away from the wall at least the distance of the projection. 2” x 4” framing whose outside dimensions match the overall dimensions of the mounting plate is recommended. The 2” x 4” framing protects siding from possible warpage or discoloration. All joints can then be sealed and painted. The wall depth plus the additional depth of the 2” x 4” framing should not exceed a total depth of 14” for DVC-35T. (See Figure 10)

Vinyl siding vent kit, DV-822, is available from Empire Comfort Systems, Inc. The depth is 3”, which enables the vent cap to be extended away from siding or projections. The wall depth plus the additional 3” depth of the vinyl siding vent cap extension should not exceed a total depth of 19” for DVC-35T. (See Figure 11)

Warning: When vinyl siding vent kit, DV-822 or 2” x 4” framing is added to an existing installation (furnace is installed) do not attempt to add sections of pipe to the flue outlet tube or air inlet tube. An air tight seal is required for both tubes. Refer to Parts List, page 16 to order tubes.

Figure 10

Figure 11

13119-6-0107

Page 11

Image 11
Contents Installation Instructions Table of Contents Vent KIT Information Important Safety InformationMeasure under any condition Safety Information for Users of LP-GASLearn to recognize the odor of LP-gas. Your local LP-Gas Have any question about the gas odor, call your LP-gasClear of ALL Obstructions Requirements for MassachusettsIntroduction SpecificationsRecommended Gas Pipe Diameter Installing a New Main Gas CockGAS Supply Locating Gas SupplyClearances ClearancesChecking Manifold Pressure Locating Wall Opening Installation InstructionsInstalling Optional Side Outlets Attaching Furnace to Wall Installation of Three-prong Grounding Plug AssemblyUsing Plastic Expansion Anchors Locating Electric SupplyReassembly And Resealing Vent-Air Intake System Installing Vent AssemblyDVC-35T Standing Pilot Lighting Instructions For Your Safety Read Before LightingFor Your Safety Read Before Operating IP-Model Pilot Pilot Flame CharacteristicsPilot Flame Adjustment DVC-35T Main Burner Flame CharacteristicsWiring Thermostat InstallationLadder Wiring DIAGRAM-IP Valve Service and Maintenance Suggestions DVC-35IPT Intermittent Pilot Sequence of Operation DVC-35IPT Intermittent Pilot System Troubleshooting Sequence Parts List HOW to Order Repair PartsParts View Service Notes Service Notes 13119-6-0107

DVC-35T-1, DVC-35IPT-1 specifications

Empire Products has long been recognized for its commitment to delivering high-quality heating solutions, and two notable offerings are the DVC-35T-1 and DVC-35IPT-1 gas-burning direct vent fireplaces. These units are designed to provide both comfort and aesthetic appeal, making them excellent choices for any home environment.

The DVC-35T-1 model boasts a classic design, paired with modern efficiency. With a heat output of 35,000 BTUs, it effectively warms spaces up to 1,100 square feet, ensuring even heat distribution throughout the room. One of the standout features is its advanced venting system, which allows for horizontal or vertical venting options, making it versatile for different installation layouts. The DVC-35T-1 also comes equipped with an adjustable flame control, enabling users to customize the ambiance to their preference. Its glass viewing area enhances the overall aesthetic while providing a full view of the flames.

On the other hand, the DVC-35IPT-1 model features an innovative design that incorporates a premium fireplace insert. This unit is specifically engineered to fit into existing fireplaces, transforming traditional wood-burning setups into efficient gas-burning heating sources. Like its counterpart, the DVC-35IPT-1 offers a maximum heat output of 35,000 BTUs, providing substantial warmth tailored for spaces up to 1,100 square feet. It is equipped with a state-of-the-art electronic ignition system, which ensures reliable and easy starts every time. The unit also includes a decorative log set that adds to its realism and charm, allowing for a cozy, inviting atmosphere.

Both models prioritize efficiency, with an impressive thermal efficiency rating, which not only helps in reducing heating costs but also makes them environmentally friendly options. The incorporation of a sealed combustion system ensures that indoor air quality is maintained, as it draws outside air for combustion and expels exhaust gases outdoors.

In addition to their technical features, the DVC-35T-1 and DVC-35IPT-1 are designed with user convenience in mind. Remote control capabilities allow for effortless operation, while easy maintenance ensures that homeowners spend less time worrying about upkeep and more time enjoying their fireplaces.

Overall, the Empire Products DVC-35T-1 and DVC-35IPT-1 fireplaces represent a blend of efficiency, technology, and aesthetic appeal, making them ideal options for those looking to enhance their home environment with reliable and stylish heating solutions.