Empire Products DVC-35T-1, DVC-35IPT-1 Requirements for Massachusetts, Clear of ALL Obstructions

Page 5

REQUIREMENTS FOR MASSACHUSETTS

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

1.INSTALLATION OF CARBON MONOXIDE DETEC- TORS.At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors

a.In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

b.In the event that the requirements of this subdivision can not be met at the time of completion of installa- tion, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

2.APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

3.SIGNAGE.Ametal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GASVENTDIRECTLYBELOW. KEEP

CLEAR OF ALL OBSTRUCTIONS”.

4.INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxidedetectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a) 1 through 4.

(b)EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

1.The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and

2.Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.

(c)MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

1.Detailed instructions for the installation of the venting system design or the venting system components; and

2.Acomplete parts list for the venting system design or venting system.

(e)A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instruc- tions shall remain with the appliance or equipment at the completion of the installation.

13119-6-0107

Page 5

Image 5
Contents Installation Instructions Table of Contents Vent KIT Information Important Safety InformationLearn to recognize the odor of LP-gas. Your local LP-Gas Safety Information for Users of LP-GASHave any question about the gas odor, call your LP-gas Measure under any conditionClear of ALL Obstructions Requirements for MassachusettsIntroduction SpecificationsGAS Supply Installing a New Main Gas CockLocating Gas Supply Recommended Gas Pipe DiameterClearances ClearancesChecking Manifold Pressure Locating Wall Opening Installation InstructionsInstalling Optional Side Outlets Using Plastic Expansion Anchors Installation of Three-prong Grounding Plug AssemblyLocating Electric Supply Attaching Furnace to WallReassembly And Resealing Vent-Air Intake System Installing Vent AssemblyDVC-35T Standing Pilot Lighting Instructions For Your Safety Read Before LightingFor Your Safety Read Before Operating IP-Model Pilot Pilot Flame CharacteristicsPilot Flame Adjustment Wiring Main Burner Flame CharacteristicsThermostat Installation DVC-35TLadder Wiring DIAGRAM-IP Valve Service and Maintenance Suggestions DVC-35IPT Intermittent Pilot Sequence of Operation DVC-35IPT Intermittent Pilot System Troubleshooting Sequence Parts List HOW to Order Repair PartsParts View Service Notes Service Notes 13119-6-0107

DVC-35T-1, DVC-35IPT-1 specifications

Empire Products has long been recognized for its commitment to delivering high-quality heating solutions, and two notable offerings are the DVC-35T-1 and DVC-35IPT-1 gas-burning direct vent fireplaces. These units are designed to provide both comfort and aesthetic appeal, making them excellent choices for any home environment.

The DVC-35T-1 model boasts a classic design, paired with modern efficiency. With a heat output of 35,000 BTUs, it effectively warms spaces up to 1,100 square feet, ensuring even heat distribution throughout the room. One of the standout features is its advanced venting system, which allows for horizontal or vertical venting options, making it versatile for different installation layouts. The DVC-35T-1 also comes equipped with an adjustable flame control, enabling users to customize the ambiance to their preference. Its glass viewing area enhances the overall aesthetic while providing a full view of the flames.

On the other hand, the DVC-35IPT-1 model features an innovative design that incorporates a premium fireplace insert. This unit is specifically engineered to fit into existing fireplaces, transforming traditional wood-burning setups into efficient gas-burning heating sources. Like its counterpart, the DVC-35IPT-1 offers a maximum heat output of 35,000 BTUs, providing substantial warmth tailored for spaces up to 1,100 square feet. It is equipped with a state-of-the-art electronic ignition system, which ensures reliable and easy starts every time. The unit also includes a decorative log set that adds to its realism and charm, allowing for a cozy, inviting atmosphere.

Both models prioritize efficiency, with an impressive thermal efficiency rating, which not only helps in reducing heating costs but also makes them environmentally friendly options. The incorporation of a sealed combustion system ensures that indoor air quality is maintained, as it draws outside air for combustion and expels exhaust gases outdoors.

In addition to their technical features, the DVC-35T-1 and DVC-35IPT-1 are designed with user convenience in mind. Remote control capabilities allow for effortless operation, while easy maintenance ensures that homeowners spend less time worrying about upkeep and more time enjoying their fireplaces.

Overall, the Empire Products DVC-35T-1 and DVC-35IPT-1 fireplaces represent a blend of efficiency, technology, and aesthetic appeal, making them ideal options for those looking to enhance their home environment with reliable and stylish heating solutions.