Empire Products DVC-35T-1, DVC-35IPT-1 Important Safety Information, Vent KIT Information

Page 3

IMPORTANT SAFETY INFORMATION

THIS IS A HEATING APPLIANCE

DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED.

Due to high temperatures the appliance should be located

• DO NOT put anything around the furnace that will ob-

out of traffic and away from furniture and draperies.

struct the flow of combustion and ventilation air.

• Children and adults should be alerted to the hazards of

• DO keep the appliance area clear and free from combus-

high surface temperatures and should stay away to avoid

tible material, gasoline and other flammable vapors and

burns or clothing ignition.

liquids.

• Young children should be carefully supervised when they

• DO examine venting system periodically and replace

are in the same room as the appliance.

damaged parts.

• Clothing orotherflammable material should not be placed

• DO make a periodic visual check of pilot and burners.

on or near the appliance.

Clean and replace damaged parts.

• Any safety screen orguard removed forservicing an appli-

• CAUTION: Pilot hole cover must be kept tightly closed

ance must be replaced prior to operating the appliance.

during operation.

• Keep burner and control compartment clean.

• DO NOT use this heater if any part has been under water.

• Vent cap hot while furnace is in operation.

Immediately call a qualified service technician to inspect

• Installation and repair should be done by a QUALIFIED

the heater and to replace any part of the control system

SERVICE PERSON. The appliance should be inspected

and any gas control which has been under water.

before use and at least annually by a qualified service

 

 

• IMPORTANT:This furnace has a washable permanent

 

person. More frequent cleaning may be required due to

 

excessive lint from carpeting, bedding materials, etc. It

type filter which should be cleaned at least once per

 

is imperative that control compartments, burners and

year before the heating season. For dirty or high use

 

circulating air passageways of the appliance be kept

areas more frequent cleaning is required.

 

clean.

 

 

 

 

 

VENT KIT INFORMATION

Attention: The DVC-35T and DVC-35IPT direct vent wall furnaces are provided with vent kit, DV4T-59-1 for wall depths of 5” to 9”. For wall depths greater than 9”, refer to Accessories, Page 6. Listed below are the vent kits.

Attention: The minimum wall depth for installation of a DVC-35T and DVC-35IPT MUST BE 5”. If the wall depth is less than 5” you can order DV-822, refer to Accessories, Page 6 or refer to Figure 10 and Figure 11 with accompanying text, Page 11.

Vent Kits

No.

Part

DV4T-59-1

DV4T-812-1

DV4T-1219-1

1

Outlet Tube - Inner

13057

13057

13058

2

Gasket - Outer Collar

M-177

M-177

M-177

 

 

 

 

 

3

Outlet Tube - Inner

13104

13104

13105

 

 

 

 

 

4

Inlet Tube - Inner

13062

13062

13063

 

 

 

 

 

5

Gasket - Inlet Collar

M-178

M-178

M-178

 

 

 

 

 

6

Inlet Tube - Inner

13106

13106

13107

 

 

 

 

 

7

Inlet Tube - Outer

13064

13065

13066

 

 

 

 

 

8

Outlet Tube - Outer

13059

13060

13061

 

 

 

 

 

9

Vent Cap

13053

13053

13053

 

 

 

 

 

 

Hardware Kit

13078

13078

13078

 

 

 

 

 

13119-6-0107

Page 3

Image 3
Contents Installation Instructions Table of Contents Vent KIT Information Important Safety InformationMeasure under any condition Safety Information for Users of LP-GASLearn to recognize the odor of LP-gas. Your local LP-Gas Have any question about the gas odor, call your LP-gasClear of ALL Obstructions Requirements for MassachusettsIntroduction SpecificationsRecommended Gas Pipe Diameter Installing a New Main Gas CockGAS Supply Locating Gas SupplyClearances Checking Manifold PressureClearances Installation Instructions Installing Optional Side OutletsLocating Wall Opening Attaching Furnace to Wall Installation of Three-prong Grounding Plug AssemblyUsing Plastic Expansion Anchors Locating Electric SupplyReassembly And Resealing Vent-Air Intake System Installing Vent AssemblyDVC-35T Standing Pilot Lighting Instructions For Your Safety Read Before LightingFor Your Safety Read Before Operating Pilot Flame Characteristics Pilot Flame AdjustmentIP-Model Pilot DVC-35T Main Burner Flame CharacteristicsWiring Thermostat InstallationLadder Wiring DIAGRAM-IP Valve Service and Maintenance Suggestions DVC-35IPT Intermittent Pilot Sequence of Operation DVC-35IPT Intermittent Pilot System Troubleshooting Sequence Parts List HOW to Order Repair PartsParts View Service Notes Service Notes 13119-6-0107

DVC-35T-1, DVC-35IPT-1 specifications

Empire Products has long been recognized for its commitment to delivering high-quality heating solutions, and two notable offerings are the DVC-35T-1 and DVC-35IPT-1 gas-burning direct vent fireplaces. These units are designed to provide both comfort and aesthetic appeal, making them excellent choices for any home environment.

The DVC-35T-1 model boasts a classic design, paired with modern efficiency. With a heat output of 35,000 BTUs, it effectively warms spaces up to 1,100 square feet, ensuring even heat distribution throughout the room. One of the standout features is its advanced venting system, which allows for horizontal or vertical venting options, making it versatile for different installation layouts. The DVC-35T-1 also comes equipped with an adjustable flame control, enabling users to customize the ambiance to their preference. Its glass viewing area enhances the overall aesthetic while providing a full view of the flames.

On the other hand, the DVC-35IPT-1 model features an innovative design that incorporates a premium fireplace insert. This unit is specifically engineered to fit into existing fireplaces, transforming traditional wood-burning setups into efficient gas-burning heating sources. Like its counterpart, the DVC-35IPT-1 offers a maximum heat output of 35,000 BTUs, providing substantial warmth tailored for spaces up to 1,100 square feet. It is equipped with a state-of-the-art electronic ignition system, which ensures reliable and easy starts every time. The unit also includes a decorative log set that adds to its realism and charm, allowing for a cozy, inviting atmosphere.

Both models prioritize efficiency, with an impressive thermal efficiency rating, which not only helps in reducing heating costs but also makes them environmentally friendly options. The incorporation of a sealed combustion system ensures that indoor air quality is maintained, as it draws outside air for combustion and expels exhaust gases outdoors.

In addition to their technical features, the DVC-35T-1 and DVC-35IPT-1 are designed with user convenience in mind. Remote control capabilities allow for effortless operation, while easy maintenance ensures that homeowners spend less time worrying about upkeep and more time enjoying their fireplaces.