CARE AND OPERATION

“BREAK-IN” PERIOD

The finish on this appliance is a high temperature paint that requires time and temperature to completely cure. The curing process will take 2 or 3 burns (heat up and cool down peri- ods). We recommend that you ventilate the house during the initial burns. The paint emits non-toxic odors during this proc- ess.

KEEP YOUR HOUSE WELL VENTILATED DURING THE CURING PROCESS TO PREVENT ACTIVATION OF YOUR HOME SMOKE DETECTOR.

Do not turn on a blower during the break-in period. Do not place anything on the stove surface until the paint is com- pletely cured. Do not attempt to repaint the stove until the paint is completely cured. If the surface later becomes stained or marred, it may be lightly sanded and touched up with spray paint (See Small Area Paint Touch-Up, page 19). Paint is avail- able at your local authorized Lennox Hearth Products dealer. Never attempt to paint a hot stove.

COMBUSTION CHAMBER RELIEF DOORS

This appliance is equipped with 3 relief doors (one behind the back panel, and one on each side, behind side panels) in case of delayed ignition blow back. If one or more relief doors open, inspect for gasket damage. If necessary, replace with factory supplied gasket only. Confirm relief doors are closed and properly seated.

CIRCULATION BLOWER OPERATION

The speed of the circulation blower is controlled using the speed control rheostat (see following illustration) on the left hand side of the control panel. The blower system is designed with a variable speed control allowing an infinite range of blower settings to meet the customer’s needs. With the rotary switch turned fully CCW 4, the blower is off. Turning the switch CW 3 will activate the blower at its maximum speed. Further rotation of the switch in the CW direction will reduce the speed of the blower. At approximately 270° of CW 3 rota- tion, the switch provides a minimum setting for blower speed.

Thermostatic feature: With the control switch in any “ON” po- sition, the circulation blower is designed to automatically begin operation approximately 12 minutes after lighting the main burner. The blower will turn off approximately 15 minutes after the main burner is shut-off.

Variable Speed Control for Air Circulation Blower

SIDE VIEW SHOWN

KNOBRHEOSTAT

PAGE 17

Image 17
Contents 775,029M Rev. B, 8/04 Freestanding Vented GAS Fired Room HeatersRetain this Manual for Future Reference Important Warnings / Cautions Table of Contents Local and National Code Requirements Planning Your InstallationTool / Equipment List LOW HighQuestions to ASK the Local Building Official Manufactured Mobile Home Requirements Clearances to Combustible MaterialsRear Wall or Alcove CornerMax. Total Vertical Pipe Length 25 feet InstallationMax. Vertical Pipe Length 25 feet Symptoms Excessive Combustion Air Vent Restrictor Ring InstallationSV 0 SHK Direct Vent System Components Model L30 DVF-2SV4MCK Vertical Vent Termination ClearancesHorizontal Vent Termination Requirements Supply Line Size Requirements Pressure TestingGAS Supply Hookup Door Operation Glowing Embers GAS Appliance Final AssemblyInstalling LOG SET Adjust gap as shown in following picture Installation Check ListCare and Operation Pilot AssemblyGas Control Knobs Lighting and Shutdown InstructionsCombustion Chamber Relief Doors BREAK-IN PeriodCirculation Blower Operation Variable Speed Control for Air Circulation BlowerPropane Conversion Procedure Parts ListPropane Conversion CanadaBurner Flame Appearance Reference InformationMaintenance Periodic Check of Pilot and Burner Flames Air Shutter AdjustmentCycle unit a minimum of 2 times Pilot Flame AppearanceCirculating Blower Wiring Diagram Wiring DiagramsGAS Control and Safety System Wiring Diagram Troubleshooting Qualified Technicians Only Item # Description Cat. No Replacement Parts Model L30 DVF-2Item # Description Catalog # Model Optional AccessoriesDards. Z21.88-1998 CSA 2.33a M98 Safety TestVented Gas Fireplace Heater Top View Side ViewSafety / Listing Label Rating Plate Ownership Records Service and Maintenance LOG775,029M REV. B 08/2004

L30 DVF-2 specifications

The Lennox Hearth L30 DVF-2 is an impressive direct vent gas fireplace known for its aesthetic appeal and innovative technologies. This model stands out in the realm of residential heating solutions, combining efficiency, performance, and design into a singular unit that enhances any living space.

One of the primary features of the L30 DVF-2 is its efficient heating capacity. With a heating output of up to 30,000 BTUs, it effectively warms large areas while maintaining a steady and comfortable indoor climate. This model uses a direct vent system, allowing for clean and safe operation by taking air from the outside for combustion and expelling exhaust gases outside as well. This not only minimizes the risk of indoor air pollution but also allows for versatile installation options without the need for a traditional chimney.

In terms of design, the L30 DVF-2 offers a sleek and modern appearance, making it a stylish addition to any room. The fireplace features a large viewing area with a contemporary surround that can be customized in various finishes to match the décor of your home. Additionally, a variety of decorative options such as glass media and ceramic logs add to its aesthetic appeal, providing a beautiful flame presentation.

The Lennox L30 DVF-2 is also equipped with advanced technology, including an electronic ignition system that ensures reliable startups without requiring manual assistance. The fireplace can be conveniently controlled using a wall switch or remote control, allowing users to adjust the heat and flame settings with ease. The model is designed with a blower option that enhances heat distribution, helping to circulate warm air throughout the room more effectively.

Moreover, energy efficiency is a hallmark of the L30 DVF-2. Rated with a high Annual Fuel Utilization Efficiency (AFUE), this fireplace not only provides warmth but does so while minimizing energy consumption and utility costs. This efficiency extends the value of your investment by ensuring lower operating expenses over time.

Overall, the Lennox Hearth L30 DVF-2 combines cutting-edge technology, aesthetic versatility, and energy efficiency into a gas fireplace that offers both style and substance. It caters to modern homeowners looking to enhance their living spaces with a reliable and attractive heating solution.