Lennox Hearth L30 DVF-2 operation manual Parts List, Canada, Propane Conversion Procedure

Page 18

PROPANE CONVERSION

PROPANE CONVERSION PROCEDURE (Only required if Propane gas is used)

This appliance is designed to operate on natural gas, or propane (LP). It is factory set for use with natural gas and requires field conversion for use with propane. The use of other fuels or com- bination of fuels will degrade the performance of this system and may be dangerous.

When converting to Propane Gas (LP), it may be necessary to install (as a minimum) 3 feet of vertical pipe from the appli- ance prior to an offset to ensure optimum product performance. This may be necessary due to variations in vent configuration and other numerous factors which affect exhaust flow and air delivery such as BTU value, ambient temperature, wind condi- tions, altitude, etc.

The conversion kit provided with this appliance contains com- ponents required to convert this appliance from use with natural gas to use with propane (LP) Gas. All of the components in the propane conversion kit must be installed in order for the appli- ance to operate safely on propane.

Installation Tools / Supplies 7/16” Open end wrench Small standard screwdriver

Pipe sealant compound (must be rated for use with LPG gas)

Parts List

Propane RB Regulator conversion screw (Red indicates LP gas)

Burner Orifice (If you are at an elevation above 4500 feet do not use the orifice provided in this kit. Contact your gas supplier to obtain a smaller orifice)

Pilot Orifice

Label, Converted to (LP) Propane – Affix to valve

Label, Converted to (LP) Propane – Affix to stove body

Avertissement: cet équipement de conversion sera installé par une agence qualifiée de service conformément aux instructions du fabricant et toutes exigences et codes applicables de l’autorisés avoir la juridiction. Si l’information dans cette in- struction n’est pas suivie exactement, un feu, explosion ou pro- duction de protoxyde de carbone peut résulter le dommages causer de propriété, perte ou blessure personnelle de vie. L’agence qualifiée de service est esponsable de l’installation propre de cet équipment. L’installation n’est pas propre et compléte jusqu’à l’opération de l’appareil converti est chéque suivant les critères établis dans les instructions de propriétaire provisionnées avec l’équipement.

IN CANADA:

The conversion shall be carried out in accordance with the re- quirements of the provincial authorities having jurisdiction and in accordance with the requirements of the CAN1-B149.1 and .2 Installation code.

La conversion devra être effectuée conformément aux recom- mandations des autorités provinciales ayant juridiction et con- formément aux exigences du code d’installation CAN1-B149.1 ET.2.

PROPANE Conversion Procedure

1.Turn off Gas - Turn gas control knob to the off position, and shut off the gas supply to the valve. If necessary, disconnect appliance from gas supply.

2.Caution: The gas supply shall be shut off prior to disconnect- ing the electrical power, before proceeding with the conver- sion. Unplug blower power cord.

3.If the installation is at an elevation below 4500 feet, proceed to step 4. If you are at an elevation above 4500 feet, do not use the orifice provided in this kit. Contact your gas supplier to obtain a smaller orifice).

4.Burner Orifice Installation Procedure:

a.Remove glass door.

b.Remove logs, burner cover, and burner.

c.Use a 7/16” open-end wrench to remove gas burner ori- fice.

d.Replace the burner orifice with the appropriate burner orifice (see instruction #3).

e.Use pipe sealing compound rated for LP gas. BE VERY CAREFUL THAT THE PIPE COMPOUND DOES NOT GET INSIDE OF THE ORIFICE (THIS COULD RESULT IN PLUGGING OF THE ORIFICE). Using a 7/16” open-end wrench to tighten orifice - DO NOT OVER TIGHTEN (fin- ger tight, then 1/2 turn maximum). *Make sure the ori- fice is inserted fully into the primary air shutter fixed opening.

5.Adjust primary air shutter. Burner Air Shutter opening to be: Natural Gas – 1/2 open, Propane 3/4 open. Some adjustment from standard may be necessary for the desired flame char- acteristics (see Burner Flame Appearance, page 20).

6.Replace Pilot Orifice - Using a 7/16” open-end wrench, re- move the pilot burner hood. Replace the pilot orifice with the one supplied in the propane conversion kit. Then, reinstall the pilot burner hood. Ensure that the mark on the pilot hood is lined up with the mark on the pilot mounting plate.

PAGE 18

Image 18
Contents Freestanding Vented GAS Fired Room Heaters Retain this Manual for Future Reference775,029M Rev. B, 8/04 Important Warnings / Cautions Table of Contents Tool / Equipment List Planning Your InstallationLocal and National Code Requirements LOW HighQuestions to ASK the Local Building Official Rear Wall or Alcove Clearances to Combustible MaterialsManufactured Mobile Home Requirements CornerInstallation Max. Vertical Pipe Length 25 feetMax. Total Vertical Pipe Length 25 feet Vent Restrictor Ring Installation Symptoms Excessive Combustion AirDirect Vent System Components Model L30 DVF-2 SV 0 SHKVertical Vent Termination Clearances SV4MCKHorizontal Vent Termination Requirements Pressure Testing GAS Supply HookupSupply Line Size Requirements Door Operation GAS Appliance Final Assembly Installing LOG SETGlowing Embers Installation Check List Adjust gap as shown in following pictureGas Control Knobs Pilot AssemblyCare and Operation Lighting and Shutdown InstructionsCirculation Blower Operation BREAK-IN PeriodCombustion Chamber Relief Doors Variable Speed Control for Air Circulation BlowerPropane Conversion Parts ListPropane Conversion Procedure CanadaReference Information Burner Flame AppearanceMaintenance Cycle unit a minimum of 2 times Air Shutter AdjustmentPeriodic Check of Pilot and Burner Flames Pilot Flame AppearanceWiring Diagrams GAS Control and Safety System Wiring DiagramCirculating Blower Wiring Diagram Troubleshooting Qualified Technicians Only Replacement Parts Model L30 DVF-2 Item # Description Cat. NoOptional Accessories Item # Description Catalog # ModelVented Gas Fireplace Heater Safety TestDards. Z21.88-1998 CSA 2.33a M98 Top View Side ViewSafety / Listing Label Rating Plate Service and Maintenance LOG Ownership Records775,029M REV. B 08/2004

L30 DVF-2 specifications

The Lennox Hearth L30 DVF-2 is an impressive direct vent gas fireplace known for its aesthetic appeal and innovative technologies. This model stands out in the realm of residential heating solutions, combining efficiency, performance, and design into a singular unit that enhances any living space.

One of the primary features of the L30 DVF-2 is its efficient heating capacity. With a heating output of up to 30,000 BTUs, it effectively warms large areas while maintaining a steady and comfortable indoor climate. This model uses a direct vent system, allowing for clean and safe operation by taking air from the outside for combustion and expelling exhaust gases outside as well. This not only minimizes the risk of indoor air pollution but also allows for versatile installation options without the need for a traditional chimney.

In terms of design, the L30 DVF-2 offers a sleek and modern appearance, making it a stylish addition to any room. The fireplace features a large viewing area with a contemporary surround that can be customized in various finishes to match the décor of your home. Additionally, a variety of decorative options such as glass media and ceramic logs add to its aesthetic appeal, providing a beautiful flame presentation.

The Lennox L30 DVF-2 is also equipped with advanced technology, including an electronic ignition system that ensures reliable startups without requiring manual assistance. The fireplace can be conveniently controlled using a wall switch or remote control, allowing users to adjust the heat and flame settings with ease. The model is designed with a blower option that enhances heat distribution, helping to circulate warm air throughout the room more effectively.

Moreover, energy efficiency is a hallmark of the L30 DVF-2. Rated with a high Annual Fuel Utilization Efficiency (AFUE), this fireplace not only provides warmth but does so while minimizing energy consumption and utility costs. This efficiency extends the value of your investment by ensuring lower operating expenses over time.

Overall, the Lennox Hearth L30 DVF-2 combines cutting-edge technology, aesthetic versatility, and energy efficiency into a gas fireplace that offers both style and substance. It caters to modern homeowners looking to enhance their living spaces with a reliable and attractive heating solution.