Lennox Hearth operation manual Direct Vent System Components Model L30 DVF-2, SV 0 SHK

Page 9

INSTALLATION See Pipe Manufacturers Instructions For Installation Of Venting Components & Clearances.

DIRECT VENT SYSTEM COMPONENTS – Model L30 DVF-2

The following Direct-Vent system components may be safely used with this appliance.

Model #

Brand: SECURITY / Description

Model #

Brand: SIMPSON DURA-VENT / Description

 

 

 

 

SV 0 SHK

Standard Horizontal Term. Kit (90° Black Elbow, Firestop (2),

970

Basic Horizontal Term. Kit (90° Black Elbow, Wall Thimble

 

Horizontal Square Term. Cap)

 

Cover, Horizontal Square Term. Cap)

SV 0 HK

Horizontal Term. Kit (90° Black Elbow, Firestop (2), Horizontal

971

Horizontal Term. Kit A (90° Black Elbow, Wall Thimble

 

Term. Cap, adj. Black length 1-1/2 – 6”)

 

Cover, Horizontal Square Term. Cap, adj. 24” black pipe,

 

 

 

11-14 5/8” adj. Black pipe)

SV 0 FK

Vertical Flat Roof Term. Kit (w/flashing, storm collar, vertical

973

Vertical Termination Kit

 

Term. Cap)

 

 

SV 0 FAK

Vertical pitched Roof Kit, 1/12-7/12 (with adjustable roof flash-

978

Vertical Pitched Roof Kit, 0/12–6/12 (with adjustable flash-

 

ing, storm collar, vertical termination cap)

 

ing, storm collar, low profile term. Cap)

SV 0 FBK

Vertical pitched Roof Kit, 8/12-12/12 (with adjustable roof

N/A

N/A

 

flashing, storm collar, vertical termination cap)

 

 

SV 0 L6

6” Pipe Length (Galvalume)

 

6” Pipe Length (Galvalume)

SV0 LB6

6” Pipe Length (Black)

908B

6” Pipe Length (Black)

SV 0

9” Pipe Length ( Black)

907B

9” Pipe Length ( Black)

SV 0 L12

12” Pipe Length (Galvalume)

906

12” Pipe Length (Galvanized)

SL 0 LB12

12” Pipe Length (Black)

906B

12” Pipe Length (Black)

SV 0 L24

24” Pipe Length (Galvalume)

904

24” Pipe Length (Galvanized)

SV 0 LB24

24” Pipe Length (Black)

904B

24” Pipe Length (Black)

SV 0 L36

36” Pipe Length (Galvalume)

903

36” Pipe Length (Galvanized)

SV 0 LB36

36” Pipe Length (Black)

903B

36” Pipe Length (Black)

SV 0 L48

48” Pipe Length (Galvalume)

902

48” Pipe Length (Galvanized)

SV 0 LB48

48” Pipe Length (Black)

902B

48” Pipe Length (Black)

N/A

N/A

911B

11”-14” Adj. Pipe Length (Black)

SV 0 LA

1 ½- 6” Adj. Pipe Length

N/A

N/A

SV 0 LBA

1 ½- 6” Adj. Black Pipe Length

N/A

N/A

SV 0 E45

45 Elbow (Galvalume)

945

45 Elbow (Galvanized)

SV 0 EB45

45 Elbow (Black)

945B

45 Elbow (Black)

SV 0 E90

90 Elbow (Galvalume Swivel)

990G

90 Elbow (Galvanized Swivel)

SV 0 EB90

90 Elbow (Black Swivel)

990BG

90 Elbow (Black Swivel)

SV 0

90 Elbow (Galvalume)

990

90 Elbow (Galvanized)

SV 0

90 Elbow (Black)

990B

90 Elbow (Black)

SV 0 CHC

Horizontal Standard Term. Cap

984

Horizontal Standard Term. Cap

SV 0 CHCV

Horizontal High Wind Term. Cap

N/a

Horizontal High Wind Term. Cap

SV 0 CPB

Vertical Termination Cap

983

Vertical Termination Cap

SV 0 CGV

Vertical High Wind Cap

991

Vertical High Wind Cap

SV 0 STC36

Snorkel Termination Cap 36”

981

Snorkel Termination Cap 36”

SV 0 STC14

Snorkel Termination Cap 14”

982

Snorkel Termination Cap 14”

SV 0

Vinyl Shield Protector

950

Vinyl Siding Standoff

SV 0 VS

Round Ceiling Support

940

Round Ceiling Support

 

/ Wall Thimble Cover

 

/ Wall Thimble Cover

SV 0 CSB

Cathedral Ceiling Support Box, decorative square

941

Cathedral Ceiling Support Box

SV 0 SF

Black Plate, Decorative

N/A

N/A

SV 0

Round Ceiling Support Box/Wall

942

Round Ceiling Support Box/Wall

 

Thimble

 

Thimble

SV 0

Storm Collar

953

Storm Collar

SV 0 RSM

Wall Radiation Shield

N/A

N/A

SV 0 BF

Firestop

N/A

N/A

N/A

N/A

963

Firestop Spacer

SV 0 F

Flashing, Flat Roof (storm collar included)

 

 

SV 0 FA

Flashing, Adjustable roof 1/12-7/12 (storm collar

943

Flashing 0/12-6/12

 

included)

 

 

SV 0 FB

Flashing, Adjustable 8/12-12/12 (storm collar included)

943S

Flashing 7/12-12/12

SV 0 BM

Wall Band

988

Wall Strap

Snorkel Caps: These are elongate vent termination caps, which incorporate the principles of natural draft into a horizontal installa-

tion. Two styles are common, 14” and 36” (Cap height). They enhance draft and relieve backpressure by creating natural draft in the snorkel.

Horizontal Caps: This 13 ½” square horizontal cap is placed on the outer wall of the dwelling. Not to be within 9” of an air inlet or

within 12” of the ground. It requires a minimum 2’ rise on the interior pipe.

Vertical Termination Cap: Low profile and high wind caps can only be used on vertical pipe installations.

PAGE 9

Image 9
Contents Freestanding Vented GAS Fired Room Heaters Retain this Manual for Future Reference775,029M Rev. B, 8/04 Important Warnings / Cautions Table of Contents Local and National Code Requirements Planning Your InstallationTool / Equipment List LOW HighQuestions to ASK the Local Building Official Manufactured Mobile Home Requirements Clearances to Combustible MaterialsRear Wall or Alcove CornerInstallation Max. Vertical Pipe Length 25 feetMax. Total Vertical Pipe Length 25 feet Symptoms Excessive Combustion Air Vent Restrictor Ring InstallationSV 0 SHK Direct Vent System Components Model L30 DVF-2SV4MCK Vertical Vent Termination ClearancesHorizontal Vent Termination Requirements Pressure Testing GAS Supply HookupSupply Line Size Requirements Door Operation GAS Appliance Final Assembly Installing LOG SETGlowing Embers Adjust gap as shown in following picture Installation Check ListCare and Operation Pilot AssemblyGas Control Knobs Lighting and Shutdown InstructionsCombustion Chamber Relief Doors BREAK-IN PeriodCirculation Blower Operation Variable Speed Control for Air Circulation BlowerPropane Conversion Procedure Parts ListPropane Conversion CanadaBurner Flame Appearance Reference InformationMaintenance Periodic Check of Pilot and Burner Flames Air Shutter AdjustmentCycle unit a minimum of 2 times Pilot Flame AppearanceWiring Diagrams GAS Control and Safety System Wiring DiagramCirculating Blower Wiring Diagram Troubleshooting Qualified Technicians Only Item # Description Cat. No Replacement Parts Model L30 DVF-2Item # Description Catalog # Model Optional AccessoriesDards. Z21.88-1998 CSA 2.33a M98 Safety TestVented Gas Fireplace Heater Top View Side ViewSafety / Listing Label Rating Plate Ownership Records Service and Maintenance LOG775,029M REV. B 08/2004

L30 DVF-2 specifications

The Lennox Hearth L30 DVF-2 is an impressive direct vent gas fireplace known for its aesthetic appeal and innovative technologies. This model stands out in the realm of residential heating solutions, combining efficiency, performance, and design into a singular unit that enhances any living space.

One of the primary features of the L30 DVF-2 is its efficient heating capacity. With a heating output of up to 30,000 BTUs, it effectively warms large areas while maintaining a steady and comfortable indoor climate. This model uses a direct vent system, allowing for clean and safe operation by taking air from the outside for combustion and expelling exhaust gases outside as well. This not only minimizes the risk of indoor air pollution but also allows for versatile installation options without the need for a traditional chimney.

In terms of design, the L30 DVF-2 offers a sleek and modern appearance, making it a stylish addition to any room. The fireplace features a large viewing area with a contemporary surround that can be customized in various finishes to match the décor of your home. Additionally, a variety of decorative options such as glass media and ceramic logs add to its aesthetic appeal, providing a beautiful flame presentation.

The Lennox L30 DVF-2 is also equipped with advanced technology, including an electronic ignition system that ensures reliable startups without requiring manual assistance. The fireplace can be conveniently controlled using a wall switch or remote control, allowing users to adjust the heat and flame settings with ease. The model is designed with a blower option that enhances heat distribution, helping to circulate warm air throughout the room more effectively.

Moreover, energy efficiency is a hallmark of the L30 DVF-2. Rated with a high Annual Fuel Utilization Efficiency (AFUE), this fireplace not only provides warmth but does so while minimizing energy consumption and utility costs. This efficiency extends the value of your investment by ensuring lower operating expenses over time.

Overall, the Lennox Hearth L30 DVF-2 combines cutting-edge technology, aesthetic versatility, and energy efficiency into a gas fireplace that offers both style and substance. It caters to modern homeowners looking to enhance their living spaces with a reliable and attractive heating solution.