MAINTENANCE

Always Turn Off Gas Control Valve Before Cleaning. Annual Maintenance Should Only Be Performed By A Qualified Service Technician:

LOG SET

Removing & Cleaning Logs - Carefully remove the logs (remov- ing top logs, then lifting front log out, then rear log). Use care when handling the fiber logs, as they become quite fragile after curing. Use a small soft-bristled brush (e.g., a nylon paint brush) to remove soot, dust or debris that may have accumu- lated on the burner or log set. Remove the logs and burner, and clean them outside the home in a location with plenty of fresh air ventilation. Avoid breathing fine particulates of dust that may be generated. See page 12, Installing Log Set for instruc- tions on reinstalling logs.

Replacing Logs - If logs become damaged by accident or im- proper handling and need replacement, use only the proper re- placement logs from manufacturer, which can be purchased from your local dealer. See page 23.

CLEANING BURNER

With the logs removed, vacuum out any foreign matter (lint, carbon etc.) on the burner. Be sure the burner ports are “open.”

CLEANING VALVE / AIR VENTURI

Clean all lint and dust build-up around the control valve and air shutter on the venturi. Inspect and clean with a brush or wire the inlet of the venturi for any spider webs or lint accumulation.

Air Shutter

Burner Assembly

Ensure opening is clear from lint, dust, spider webs, debris, etc.

INSPECT WIRING / CAUTIONS:

1)Label all wires prior to disconnection when servicing con- trols. Wiring errors can cause improper and dangerous op- eration.

2)Verify proper operation after servicing.

3)Inspect and clean all wire connections. Ensure that there is no melting or damage from rodents. Inspection should in- clude:

Terminals at the valve

On / Off switch

Wall Thermostat / Remote Control (optional kits)

VENTING SYSTEM

A periodic examination of the venting system must be per- formed to ensure that the flow of combustion and ventilation air is not obstructed (outlet and inlet is open and free from block- age). We recommend that you have your gas appliance checked yearly by your independent Lennox dealer.

If the vent-air intake system is disassembled for any reason, the service technician should follow vent manufactures instructions for proper reassembly and sealing of the vent-air intake system.

IMPORTANT – APPLIANCES INSTALLED USING SIMPSON DURA-VENT BRAND PIPE MUST SEAL ALL JOINTS WITH MILL-PAC BLACK, HIGH TEMPERATURE SEALANT.

CLEAN EXTERNAL SURFACES

External surfaces should be kept clean and dust removed form air inlets to the appliance. The flow of combustion and ventila- tion air must not be obstructed. The appliance must be kept clear and free from combustible materials, gasoline and other flammable vapors and liquids.

SMALL AREA PAINT TOUCH-UP

The stove body is painted with a quality high-temperature stove paint. Use only model TSPK-C Stove Paint, Catalog # 19L92. Do not touch-up this appliance with any other paint.

Using one small piece of 320 grit sand paper and lightly sand the blemish so that the edges are “feathered” or smooth to the touch between the painted and bare surfaces. Do not let the sand paper gum up with paint, as this will cause scratches on the metal surface. If there are any scratches, use 600 grit sand- paper instead. Mask off surfaces you do not want painted. Paint lightly over the bare surface first as this will act as an undercoat. Then paint over a larger area in smooth even strokes to blend.

See Break-In Period on page 16 for information on curing the paint.

CLEANING GLASS

The window on the gas appliance is made from a clear ceramic material and may be cleaned when cool with any non-abrasive product designed for use on glass windows. Do not use abra- sive cleaners on glass. The viewing glass should be cleaned periodically. Exterior glass may be cleaned with a glass cleaner as desired. Interior glass - use soap and water, or commercial glass cleaner recommended for stove glass.

Note: Each time the appliance is lit, it may cause condensation and fog on the glass. This condensation and fog will disappear in a few minutes.

CLEANING BLOWER INTAKE

The blower air intake requires cleaning at least once a year to remove lint, dust, etc. If there are pets in the dwelling, the intake should be cleaned at least twice a year.

PAGE 20

Image 20
Contents 775,029M Rev. B, 8/04 Freestanding Vented GAS Fired Room HeatersRetain this Manual for Future Reference Important Warnings / Cautions Table of Contents Planning Your Installation Local and National Code RequirementsTool / Equipment List LOW HighQuestions to ASK the Local Building Official Clearances to Combustible Materials Manufactured Mobile Home RequirementsRear Wall or Alcove CornerMax. Total Vertical Pipe Length 25 feet InstallationMax. Vertical Pipe Length 25 feet Vent Restrictor Ring Installation Symptoms Excessive Combustion AirDirect Vent System Components Model L30 DVF-2 SV 0 SHKVertical Vent Termination Clearances SV4MCKHorizontal Vent Termination Requirements Supply Line Size Requirements Pressure TestingGAS Supply Hookup Door Operation Glowing Embers GAS Appliance Final AssemblyInstalling LOG SET Installation Check List Adjust gap as shown in following picturePilot Assembly Care and OperationGas Control Knobs Lighting and Shutdown InstructionsBREAK-IN Period Combustion Chamber Relief DoorsCirculation Blower Operation Variable Speed Control for Air Circulation BlowerParts List Propane Conversion ProcedurePropane Conversion CanadaReference Information Burner Flame AppearanceMaintenance Air Shutter Adjustment Periodic Check of Pilot and Burner FlamesCycle unit a minimum of 2 times Pilot Flame AppearanceCirculating Blower Wiring Diagram Wiring DiagramsGAS Control and Safety System Wiring Diagram Troubleshooting Qualified Technicians Only Replacement Parts Model L30 DVF-2 Item # Description Cat. NoOptional Accessories Item # Description Catalog # ModelSafety Test Dards. Z21.88-1998 CSA 2.33a M98Vented Gas Fireplace Heater Top View Side ViewSafety / Listing Label Rating Plate Service and Maintenance LOG Ownership Records775,029M REV. B 08/2004

L30 DVF-2 specifications

The Lennox Hearth L30 DVF-2 is an impressive direct vent gas fireplace known for its aesthetic appeal and innovative technologies. This model stands out in the realm of residential heating solutions, combining efficiency, performance, and design into a singular unit that enhances any living space.

One of the primary features of the L30 DVF-2 is its efficient heating capacity. With a heating output of up to 30,000 BTUs, it effectively warms large areas while maintaining a steady and comfortable indoor climate. This model uses a direct vent system, allowing for clean and safe operation by taking air from the outside for combustion and expelling exhaust gases outside as well. This not only minimizes the risk of indoor air pollution but also allows for versatile installation options without the need for a traditional chimney.

In terms of design, the L30 DVF-2 offers a sleek and modern appearance, making it a stylish addition to any room. The fireplace features a large viewing area with a contemporary surround that can be customized in various finishes to match the décor of your home. Additionally, a variety of decorative options such as glass media and ceramic logs add to its aesthetic appeal, providing a beautiful flame presentation.

The Lennox L30 DVF-2 is also equipped with advanced technology, including an electronic ignition system that ensures reliable startups without requiring manual assistance. The fireplace can be conveniently controlled using a wall switch or remote control, allowing users to adjust the heat and flame settings with ease. The model is designed with a blower option that enhances heat distribution, helping to circulate warm air throughout the room more effectively.

Moreover, energy efficiency is a hallmark of the L30 DVF-2. Rated with a high Annual Fuel Utilization Efficiency (AFUE), this fireplace not only provides warmth but does so while minimizing energy consumption and utility costs. This efficiency extends the value of your investment by ensuring lower operating expenses over time.

Overall, the Lennox Hearth L30 DVF-2 combines cutting-edge technology, aesthetic versatility, and energy efficiency into a gas fireplace that offers both style and substance. It caters to modern homeowners looking to enhance their living spaces with a reliable and attractive heating solution.