FTF10 OFFSET ELEVATION CHART

 

A

B

 

FTF10-ES30

 

Number of FTF10

Offset

Height

Offset/Return

FTF10-S4

Chimney Sections

 

 

 

 

 

 

 

(Inches)

(Inches)

Elbow Set

Stabilizer

12"

18"

36"

 

 

 

 

 

 

 

 

 

4

 

15

³⁄₄

1

0

0

0

0

9

 

24

¹⁄₂

1

0

1

0

0

12

 

29

³⁄₄

1

0

0

1

0

14

¹⁄₄

33

¹⁄₂

1

0

2

0

0

17

¹⁄₄

38

¹⁄₂

1

0

1

1

0

20

¹⁄₄

43

³⁄₄

1

0

0

2

0

21

 

45

¹⁄₄

1

0

0

0

1

22

¹⁄₄

47

¹⁄₂

1

0

2

1

0

25

¹⁄₄

52

¹⁄₂

1

0

1

2

0

26

¹⁄₄

54

¹⁄₄

1

0

1

0

1

28

¹⁄₄

57

³⁄₄

1

0

0

3

0

29

¹⁄₄

59

¹⁄₄

1

0

0

1

1

31

¹⁄₄

63

 

1

0

2

0

1

32

¹⁄₂

65

 

1

0

4

1

0

34

¹⁄₄

68

¹⁄₄

1

0

1

1

1

36

¹⁄₄

71

³⁄₄

1

0

3

0

1

37

¹⁄₄

73

¹⁄₄

1

0

0

2

1

38

¹⁄₄

75

 

1

0

0

0

2

39

¹⁄₄

77

 

1

0

2

1

1

41

¹⁄₂

80

¹⁄₂

1

0

1

4

0

43

¹⁄₄

83

³⁄₄

1

0

1

0

2

44

¹⁄₂

85

³⁄₄

1

0

3

1

1

45

¹⁄₄

87

¹⁄₂

1

0

0

3

1

46

¹⁄₄

89

 

1

0

0

1

2

48

¹⁄₄

91

¹⁄₂

1

0

2

0

2

49

¹⁄₂

94

¹⁄₂

1

0

1

5

0

51

¹⁄₄

97

³⁄₄

1

0

1

1

2

54

¹⁄₄

103

 

1

0

0

2

2

55

¹⁄₄

104

¹⁄₂

1

0

0

0

3

56

¹⁄₂

106

¹⁄₂

1

0

2

1

2

59

¹⁄₂

111

³⁄₄

1

0

1

2

2

61

³⁄₄

116

 

1

1

1

0

3

64

³⁄₄

121

¹⁄₄

1

1

0

1

3

67

 

124

³⁄₄

1

1

2

0

3

69

 

127

³⁄₄

1

1

1

3

2

70

 

130

 

1

1

1

1

3

73

 

135

¹⁄₄

1

1

0

2

3

75

 

138

³⁄₄

1

1

2

1

3

79

 

145

¹⁄₂

1

1

1

0

4

80

¹⁄₄

147

¹⁄₂

1

1

3

1

3

82

 

150

³⁄₄

1

1

0

1

4

87

 

159

¹⁄₂

1

1

1

1

4

 

 

 

 

 

 

 

 

 

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Underside Of Chimney

Figure 37

FTF10-E30 Return Elbow*

Chimney Section (S)

FTF10-30 Offset Elbow*

B

A

*Part of Offset/Return Package Model FTF10-ES30

Figure 38

INSTALLING OFFSETS

First, review the Offset Elevation Chart and Figure 38 for reference.

Step 1. Determine the offset distance where chimney is to pass through the first ceiling- dimension “A.” To find this point on your ceil- ing, first determine the center point for a verti- cal chimney following the instructions for ver- tical installation.

Measure height to the ceiling from the top of fireplace-dimension “B.” Use the appropriate Offset Elevation Chart to find dimension “A.” Mark point where you will drive your nail to show the center point for your offset ceiling cut.

Step 2. Proceed by using the Straight Up Instal- lation Instructions for cutting and framing ceil- ing and roof openings.

13

Image 13
Contents Wood Burning Fireplaces P/N 504,217M REV. E 04/2007 Retain These Instructions For Future ReferenceWH Report No. J20017261-231 Table of Contents Precautions Typical InstallationIntroduction Clearances and Height RequirementsChimney Height Assembly OutlineChase Enclosure Before You StartPRE-INSTALLATION Notes Assembly StepsInstalling the Fireplace ClearancesBlocking Metal Safety Strips Fireplace SpecificationsFront Left SideFraming Specifications Chimney 30 Offset Through Floor Or Ceiling Installing the Chimney System8d Nail Or Equivalent 12 to 12/12 Roof Pitch Model Flat to 6/12FTF8-S4 Stabilizer FTF10 Chimney Do Not Seal Flashing Spacers FTF10 FlashingUsing a FTF10-CT1 Chase Termination Using a FTF10-CTDT Chase TerminationUsing a FTF10-CT2 Chase Termination TEN Foot Rule SummarySpecial Offset Instructions Multiple TerminationsOffset Calculations FTF10 Vertical Elevation Chart Installing Offsets FTF10 Offset Elevation ChartOptional Equipment Considerations Cold Climate Insulation Glass DoorsFireplace Finishes Mantels and TrimUsing the k formula Minimum Hearth Extension DimensionsUsing the r formula Minimum Value per Inch Methods of Determining Hearth Extension and Wall ShieldValue = 1/k = r x thickness of material used Calculating Minimum Thickness if Multiple Materials are UsedFinish to Your Taste Installation ComponentsMin. Distance To Round Termination 63L423 504,217M REV. E 04/2007