Honeywell VISTA-250BP, VISTA-128SIA, VISTA-128BP manual Priority Description Display

Page 30

Accessing Other Panels (cont’d)

Press

0

to exit mode. After a few seconds, the keypad displays the status

of the original partition of the original panel for the keypad. Also, this mode will end in approximately 120 seconds if no keys are pressed.

NOTES:

When performing any of the arming commands, if there are faults in any of the partitions of a panel, the system will not arm that panel, but will arm all the other partitions of the other panels.

When performing either a STAY or INSTANT arm command the system always arm in mode 1 (see page 36 Arming Perimeter Only for a detailed explanation of the STAY arming modes.

The user cannot execute another panel linking mode. To execute another panel linking mode or to access a different remote panel, the user must first exit this mode (return to the original control panel).

Priority of Displays for Multi-Partition and Multi-Panel Modes

This table shows the priority of displays if more than one of the conditions exists at the same time.

Priority

Description

Display

 

 

 

1

Fire Alarm

F

 

 

 

2

All Other Alarms

 

 

 

3

AC Loss

P

 

 

 

4

Comm Fail

C

 

 

 

5

System Low Battery

L

 

 

 

6

Trouble

T

7

Bypass

B

8

Not Ready

N

9

Ready

R

 

 

 

10

Armed STAY

S

 

 

 

11

Armed AWAY

A

 

 

 

12

Armed INSTANT

I

13

Armed MAXIMUM

M

– 30 –

Image 30
Contents VISTA-128BP/VISTA-250BP/ VISTA-128SIA Page Table of Contents Using #70 Relay Menu Mode Viewing Alarm CompanyAccess Door Control Programming Device TimersSystem Overview GeneralPanel Linking System Overview cont’dPartitioned System ZonesAlarms Burglary ProtectionCarbon Monoxide Protection Device Timers Memory of AlarmUsing Schedules To Access another Partition Goto CommandMaster Keypad Operation Self-Help FeaturePhone Access & Voice Response Capability To view the abbreviated instructionsAbout The Keypads Alpha KeypadFunctions of the Keypad Function Keys LCD DisplayFunctions of the Keypad cont’d Removes IndividualFunctions of the Keypad cont’d Entry/Exit Delays General InformationSecurity Codes and Authority Levels Duress CodeQuick Arming Security Codes and Authority Levels cont’d Authority LevelsTo view your authority level and system capabilities To Exit User Edit Mode General Rules on Authority Levels and ChangesTo Add a User CodeMULTI-ACCESS ? 0 = no , 1 = YES To Change a Users Code To Delete a User Global Arming Accessing Other PartitionsTo Access another Partition To Goto another partitionAccessing Other Partitions cont’d SystemStatus Whse Disarmed HIT for Faults Fault 002 Loading Dock WindowCommon Lobby Operation Codes with Non-Global Arming How User Codes Affect the Common LobbyCodes with Global Arming Other Methods of Arming/DisarmingAccessing Other Panels Single-Partition Single-Panel ModeAccessing Other Panels cont’d Multi-Partition Multi-Panel ModeMulti-Panel View Mode Priority Description Display Typical fault display Using Ready KeyTo show faulted zones Checking For Open ZonesDisplaying All Zone Descriptors Using the 6 Bypass Key Bypassing Protection ZonesQuick Bypass Bypassing Protection Zones cont’d Viewing Bypassed ZonesGroup Bypass Zones Remaining Bypassed After Disarming Using the 3 Stay key Arming Perimeter OnlyArmed ***STAY Zone Bypassed With Entry Delay on cont’d Auto-STAY ArmingUsing the 7 Instant Key Armed *INSTANT1 Zone BypassedUsing Away Key Arming All ProtectionArmed **AWAY YOU MAY Exit NOW Using the 4 Maximum Key Armed *MAXIMUM* YOU MAY Exit NOWUsing the # + 9 Keys Quick ExitTo Quick Exit the premises To disarm the system and silence burglary or fire alarms Disarming and Silencing AlarmsUsing the 1 OFF Key Disarmed Ready to ARMDisarming Using the KeyswitchArming To arm in the Stay mode, turnChime Mode on Chime ModeUsing Key Chime Mode OFFViewing Alarm Company Messages MESSAGE. Press For 5 SecsUsing Panic Keys Panic KeysSpeed Key Macros DefiningEnter Speed KEY # Speed Key Macros cont’d ExecutingEnter User Code Access Door Control Using #70 Relay Menu Mode Enter Device noClosing DELAY? KEY 0-2 Hours Using SchedulesDelaying the Closing Time Temporary Open/Close SchedulesTo program temporary schedules Using Schedules cont’dProgramming Temporary Schedules MON Disarm Wind AM 0845AM MON ARM Window 0745AM 0845AMDays ? Mtwtfss HIT 0-7 X Programming Device Timers To enter the device timer menu modePorch Lite Enter OUTPUT# Programming Device Timers cont’d DAYS? Mtwtfss HIT 0-7 X Permanent ?Randomize Output Device Times Using #77 Instant Activation Mode Action Code Action SpecifierUsing #77 Instant Activation Mode cont’d Bypass CommandsQuit Menu MODE? To enter the Instant Activation ModeAction ? Are YOU Sure ? Zone List ?Select the partition Event Log ProceduresEnter Code + # + 6 + Select the display mode To Exit the Event Log Press at any timeSetting the Time and Date TIME/DATEUsing Test Key Testing Your SystemSilencing a Fire Alarm Fire Alarm SystemCase Of Fire Alarm Fire Display LockTrouble Conditions Typical Trouble DisplaysPower Failure Trouble Conditions cont’dRecommendations for Proper Protection Recommendations for Smoke and Heat DetectorsRecommendations for Proper Protection cont’d Recommendations for Proper Intrusion ProtectionAddition, we recommend the following Emergency Evacuation Replacing Batteries in Wireless Sensors Maintaining Your SystemTaking Care of Your System Silencing Low Battery Warning Tones at the Keypad Maintaining Your System cont’dRoutine Care Function Procedure Comments Quick Guide to System FunctionsQuick Guide to System Functions cont’d AM/PMSummary of Audible Notification Alpha Display KeypadsIndustry Canada Class B Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Access Another Partition IndexPOWER/READY Indicator ÊK5895V5*Š
Related manuals
Manual 80 pages 60.27 Kb

VISTA-128BP, VISTA-128SIA, VISTA-250BP specifications

The Honeywell VISTA-250BP and VISTA-128BP are advanced security control panels designed to provide robust protection for residential and commercial properties. These systems are part of Honeywell's VISTA series, known for their reliability and scalability, making them ideal for various applications.

One of the main features of the VISTA-250BP is its ability to support larger installations, accommodating up to 250 zones of security. This makes it an excellent choice for expansive properties or businesses that require comprehensive coverage. The VISTA-128BP is suited for smaller installations, providing support for up to 128 zones. Both panels offer flexibility in security device integration, allowing users to customize their security solutions according to their needs.

In terms of communication technologies, both panels are equipped with Honeywell's advanced encryption capabilities, ensuring that data transmission remains secure and protected from unauthorized access. They support a range of communication options, including Honeywell Total Connect, which allows users to monitor and control their security systems remotely via smartphones, tablets, or web browsers. This feature enhances convenience and responsiveness, especially for users who are frequently on the move.

Additionally, the VISTA-250BP and VISTA-128BP offer support for both wired and wireless security devices. This dual compatibility facilitates easier installations and makes it simpler for users to expand their security measures as their needs evolve. Users can seamlessly integrate devices such as door contacts, motion detectors, smoke detectors, and cameras, creating a comprehensive security blanket for their property.

Another notable characteristic of these panels is their user-friendly interface. The systems come equipped with a clear LCD display that provides real-time information and status updates, making it easy for users to navigate through various functions. Furthermore, the panels support multiple user codes, allowing different users to access the system with personalized access levels, enhancing overall security management.

Overall, the Honeywell VISTA-250BP and VISTA-128BP offer state-of-the-art security features, advanced communication technologies, and exceptional flexibility, making them ideal choices for both residential and commercial applications. Their scalability, user-friendly interfaces, and robust encryption capabilities ensure they meet the evolving needs of modern security demands.