Honeywell VISTA-250BP, VISTA-128SIA, VISTA-128BP Quick Guide to System Functions cont’d, Am/Pm

Page 72

Quick Guide to System Functions (cont’d)

 

FUNCTION

PROCEDURE

COMMENTS

 

 

Delete a User

Enter master/manager code.

Master & Manager level users can delete users.

 

 

 

Press CODE [8].

A user can only be deleted by a user with higher

 

 

 

Enter user no. to be deleted.

authority level.

 

 

 

Enter master/manager code.

 

 

 

 

Press 1 (Yes) at prompt.

 

 

 

Real-Time Clock

Enter Master code. Press [#] + [63]

Press [] or [#] to move cursor. Enter time and

 

 

 

 

date accordingly. Press any key (0-9) for

 

 

 

 

AM/PM.

 

 

Control Output

Enter security code. Press [#]

Activate output device as programmed.

 

 

Device

Enter 71 or 72.

 

 

 

 

Enter security code. Press [#]

Activate output device manually

 

 

 

Enter 70.

 

 

 

Randomize

Enter security code. Press [#]

Activate output device or system event instantly

 

 

Output Device

Enter 77.

 

 

 

 

Enter security code. Press [#]

Randomize output devices set for random

 

 

 

Enter 41

schedules

 

 

 

 

 

 

 

 

Enter security code. Press [#]

Randomize output devices set for random

 

 

 

Enter 42.

schedules with activation times between 6 PM

 

 

 

 

and 5 AM

 

 

Panel Linking

Enter the sequence used to

De-activate randomization

 

 

 

activate randomization.

 

 

 

 

Enter security code (002-050)

Activate single-panel single-partition mode.

 

 

 

Press [#]. Enter 86.

 

 

 

 

Enter security code (002-050)

Exit single-panel single-partition mode.

 

 

 

Press [#]. Enter 85.

 

 

 

 

Enter security code (002-050)

Activate multi-partition multi-panel mode.

 

 

 

Press [#]. Enter 88.

 

 

 

 

Enter security code (002-050)

Activate multi-panel view mode.

 

 

 

Press [#]. Enter 87.

 

 

 

Access Control

Enter 0.

Exit multi-partition multi-panel mode and multi-

 

 

 

 

panel view mode.

 

 

 

Enter security code. Enter 0.

Activate access relay for current partition.

 

 

 

Enter security code

Request to enter or exit at a console.

 

 

 

Press [#]. Enter 73.

 

 

 

 

Enter security code

Request to enter or exit at an access point.

 

 

 

Press [#]. Enter 74.

 

 

 

 

Enter access point number.

 

 

 

 

 

 

 

 

 

Enter security code. Press [#].

Change the access point state.

 

 

 

Enter 75. Enter access point

 

 

 

 

number.

 

 

 

 

Enter state (1-3)

 

 

 

 

 

 

 

 

 

 

 

 

– 72 –

Image 72
Contents VISTA-128BP/VISTA-250BP/ VISTA-128SIA Page Table of Contents Viewing Alarm Company Access Door ControlUsing #70 Relay Menu Mode Programming Device TimersSystem Overview GeneralSystem Overview cont’d Partitioned SystemPanel Linking ZonesAlarms Burglary ProtectionCarbon Monoxide Protection Memory of Alarm Using SchedulesDevice Timers To Access another Partition Goto CommandSelf-Help Feature Phone Access & Voice Response CapabilityMaster Keypad Operation To view the abbreviated instructionsAbout The Keypads Alpha KeypadFunctions of the Keypad Function Keys LCD DisplayFunctions of the Keypad cont’d Removes IndividualFunctions of the Keypad cont’d Entry/Exit Delays General InformationSecurity Codes and Authority Levels Duress CodeQuick Arming Security Codes and Authority Levels cont’d Authority LevelsTo view your authority level and system capabilities To Exit User Edit Mode General Rules on Authority Levels and ChangesTo Add a User CodeMULTI-ACCESS ? 0 = no , 1 = YES To Change a Users Code To Delete a User Accessing Other Partitions To Access another PartitionGlobal Arming To Goto another partitionAccessing Other Partitions cont’d SystemStatus Whse Disarmed HIT for Faults Fault 002 Loading Dock WindowCommon Lobby Operation How User Codes Affect the Common Lobby Codes with Global ArmingCodes with Non-Global Arming Other Methods of Arming/DisarmingAccessing Other Panels Single-Partition Single-Panel ModeAccessing Other Panels cont’d Multi-Partition Multi-Panel ModeMulti-Panel View Mode Priority Description Display Using Ready Key To show faulted zonesTypical fault display Checking For Open ZonesDisplaying All Zone Descriptors Using the 6 Bypass Key Bypassing Protection ZonesQuick Bypass Bypassing Protection Zones cont’d Viewing Bypassed ZonesGroup Bypass Zones Remaining Bypassed After Disarming Using the 3 Stay key Arming Perimeter OnlyArmed ***STAY Zone Bypassed With Entry Delay on cont’d Auto-STAY ArmingUsing the 7 Instant Key Armed *INSTANT1 Zone BypassedUsing Away Key Arming All ProtectionArmed **AWAY YOU MAY Exit NOW Using the 4 Maximum Key Armed *MAXIMUM* YOU MAY Exit NOWUsing the # + 9 Keys Quick ExitTo Quick Exit the premises Disarming and Silencing Alarms Using the 1 OFF KeyTo disarm the system and silence burglary or fire alarms Disarmed Ready to ARMUsing the Keyswitch ArmingDisarming To arm in the Stay mode, turnChime Mode Using KeyChime Mode on Chime Mode OFFViewing Alarm Company Messages MESSAGE. Press For 5 SecsUsing Panic Keys Panic KeysSpeed Key Macros DefiningEnter Speed KEY # Speed Key Macros cont’d ExecutingEnter User Code Access Door Control Using #70 Relay Menu Mode Enter Device noUsing Schedules Delaying the Closing TimeClosing DELAY? KEY 0-2 Hours Temporary Open/Close SchedulesUsing Schedules cont’d Programming Temporary SchedulesTo program temporary schedules MON Disarm Wind AM 0845AM MON ARM Window 0745AM 0845AMDays ? Mtwtfss HIT 0-7 X Programming Device Timers To enter the device timer menu modePorch Lite Enter OUTPUT# Programming Device Timers cont’d DAYS? Mtwtfss HIT 0-7 X Permanent ?Randomize Output Device Times Using #77 Instant Activation Mode Action Code Action SpecifierUsing #77 Instant Activation Mode cont’d Bypass CommandsTo enter the Instant Activation Mode Action ? Are YOU Sure ?Quit Menu MODE? Zone List ?Event Log Procedures Enter Code + # + 6 + Select the display modeSelect the partition To Exit the Event Log Press at any timeSetting the Time and Date TIME/DATEUsing Test Key Testing Your SystemFire Alarm System Case Of Fire AlarmSilencing a Fire Alarm Fire Display LockTrouble Conditions Typical Trouble DisplaysPower Failure Trouble Conditions cont’dRecommendations for Proper Protection Recommendations for Smoke and Heat DetectorsRecommendations for Proper Protection cont’d Recommendations for Proper Intrusion ProtectionAddition, we recommend the following Emergency Evacuation Replacing Batteries in Wireless Sensors Maintaining Your System Taking Care of Your System Silencing Low Battery Warning Tones at the Keypad Maintaining Your System cont’dRoutine Care Function Procedure Comments Quick Guide to System FunctionsQuick Guide to System Functions cont’d AM/PMSummary of Audible Notification Alpha Display KeypadsIndustry Canada Class B Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Access Another Partition IndexPOWER/READY Indicator ÊK5895V5*Š