Summary of Audible Notification

(Alpha Display Keypads)

SOUND

CAUSE

DISPLAY

LOUD,

FIRE ALARM

FIRE is displayed; descriptor of zone in alarm is

INTERRUPTED*

 

displayed.

Keypad & External

 

 

LOUD,

BURGLARY/AUDIBLE EMERGENCY

ALARM is displayed; descriptor of zone in alarm is

CONTINUOUS*

ALARM

also displayed.

Keypad & External

 

 

ONE SHORT BEEP

a. SYSTEM DISARM

a. DISARMED/READY TO ARM is displayed.

(not repeated)

b. SYSTEM ARMING ATTEMPT

b. The number and descriptor of the open protection

Keypad only

WITH AN OPEN ZONE.

zone is displayed.

 

c. BYPASS VERIFY

c. Numbers and descriptors of the bypassed

 

 

protection zones are displayed (One beep is heard

 

 

for each zone displayed). Subsequently, the

 

 

following is displayed: DISARMED BYPASS Ready

 

 

to Arm

ONE SHORT BEEP

SYSTEM IS IN TEST MODE

Opened Zone identifications will appear.

(once every 15

 

 

sec.) Keypad only

 

 

TWO SHORT BEEPS

SYSTEM IS ABOUT TO

Opened Zone identifications will appear.

(once every 5 sec.)

AUTOMATICALLY EXIT TEST

 

Keypad only

MODE

 

ONE BEEP

LOW BATTERY AT A TRANSMITTER

LO BAT displayed with description of transmitter.

(every 60 sec.)

 

 

Keypad only

 

 

TWO SHORT BEEPS

ARM AWAY OR MAXIMUM

ARMED AWAY or ARMED MAXIMUM is displayed.

Keypad only

 

Red ARMED indicator is lit.

THREE SHORT

a. ARM STAY OR INSTANT

a. ARMED STAY ZONE BYPASSED or ARMED

BEEPS

b. ZONE OPENED WHILE SYSTEM

INSTANT ZONE BYPASSED is displayed. Red

Keypad only

IS IN CHIME MODE.

ARMED indicator is lit.

 

c. ENTRY WARNING**

b. CHIME displayed, descriptor of open protection

 

 

zone will be displayed if the [] key is pressed.

 

 

c. DISARM SYSTEM OR ALARM WILL OCCUR is

 

 

displayed.

RAPID BEEPING

a. TROUBLE

a. CHECK displayed. Descriptor of troubled

Keypad only

b. AC POWER LOSS ALERT***

protection zone is displayed.

 

c. MEMORY OF ALARM

b. AC LOSS displayed (may alternate with other

 

 

displays that may be present).

 

 

c. FIRE or ALARM is displayed; descriptor of zone in

 

 

alarm is displayed.

SLOW BEEPING

a. ENTRY DELAY WARNING**

a. DISARM SYSTEM OR ALARM WILL OCCUR is

Keypad only

b. EXIT DELAY WARNING

displayed. Exceeding the delay time without

 

(if programmed)

disarming causes alarm.

 

 

b. ARMED AWAY or ARMED MAXIMUM is displayed

 

 

along with You May Exit Now

*If bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.

**Entry warning may consist of three short beeps or slow continuous beeping, as programmed by your installer.

***Loss of system battery power is not indicated or annunciated by the keypad (warnings are for loss of AC power only).

73 –

Image 73
Contents VISTA-128BP/VISTA-250BP/ VISTA-128SIA Page Table of Contents Access Door Control Viewing Alarm CompanyUsing #70 Relay Menu Mode Programming Device TimersGeneral System OverviewPartitioned System System Overview cont’dPanel Linking ZonesBurglary Protection AlarmsCarbon Monoxide Protection Using Schedules Memory of AlarmDevice Timers To Access another Partition Goto CommandPhone Access & Voice Response Capability Self-Help FeatureMaster Keypad Operation To view the abbreviated instructionsAlpha Keypad About The KeypadsFunction Keys LCD Display Functions of the KeypadRemoves Individual Functions of the Keypad cont’dFunctions of the Keypad cont’d General Information Entry/Exit DelaysDuress Code Security Codes and Authority LevelsQuick Arming Authority Levels Security Codes and Authority Levels cont’dTo view your authority level and system capabilities General Rules on Authority Levels and Changes To Exit User Edit ModeCode To Add a UserMULTI-ACCESS ? 0 = no , 1 = YES To Change a Users Code To Delete a User To Access another Partition Accessing Other PartitionsGlobal Arming To Goto another partitionSystem Accessing Other Partitions cont’dStatus Fault 002 Loading Dock Window Whse Disarmed HIT for FaultsCommon Lobby Operation Codes with Global Arming How User Codes Affect the Common LobbyCodes with Non-Global Arming Other Methods of Arming/DisarmingSingle-Partition Single-Panel Mode Accessing Other PanelsMulti-Partition Multi-Panel Mode Accessing Other Panels cont’dMulti-Panel View Mode Priority Description Display To show faulted zones Using Ready KeyTypical fault display Checking For Open ZonesDisplaying All Zone Descriptors Bypassing Protection Zones Using the 6 Bypass KeyQuick Bypass Viewing Bypassed Zones Bypassing Protection Zones cont’dGroup Bypass Zones Remaining Bypassed After Disarming Arming Perimeter Only Using the 3 Stay keyArmed ***STAY Zone Bypassed Auto-STAY Arming With Entry Delay on cont’dArmed *INSTANT1 Zone Bypassed Using the 7 Instant KeyArming All Protection Using Away KeyArmed **AWAY YOU MAY Exit NOW Armed *MAXIMUM* YOU MAY Exit NOW Using the 4 Maximum KeyQuick Exit Using the # + 9 KeysTo Quick Exit the premises Using the 1 OFF Key Disarming and Silencing AlarmsTo disarm the system and silence burglary or fire alarms Disarmed Ready to ARMArming Using the KeyswitchDisarming To arm in the Stay mode, turnUsing Key Chime ModeChime Mode on Chime Mode OFFMESSAGE. Press For 5 Secs Viewing Alarm Company MessagesPanic Keys Using Panic KeysDefining Speed Key MacrosEnter Speed KEY # Executing Speed Key Macros cont’dEnter User Code Access Door Control Enter Device no Using #70 Relay Menu ModeDelaying the Closing Time Using SchedulesClosing DELAY? KEY 0-2 Hours Temporary Open/Close SchedulesProgramming Temporary Schedules Using Schedules cont’dTo program temporary schedules MON Disarm Wind AM 0845AM MON ARM Window 0745AM 0845AMDays ? Mtwtfss HIT 0-7 X To enter the device timer menu mode Programming Device TimersPorch Lite Enter OUTPUT# DAYS? Mtwtfss HIT 0-7 X Permanent ? Programming Device Timers cont’dRandomize Output Device Times Action Code Action Specifier Using #77 Instant Activation ModeBypass Commands Using #77 Instant Activation Mode cont’dAction ? Are YOU Sure ? To enter the Instant Activation ModeQuit Menu MODE? Zone List ?Enter Code + # + 6 + Select the display mode Event Log ProceduresSelect the partition To Exit the Event Log Press at any timeTIME/DATE Setting the Time and DateTesting Your System Using Test KeyCase Of Fire Alarm Fire Alarm SystemSilencing a Fire Alarm Fire Display LockTypical Trouble Displays Trouble ConditionsTrouble Conditions cont’d Power FailureRecommendations for Smoke and Heat Detectors Recommendations for Proper ProtectionRecommendations for Proper Intrusion Protection Recommendations for Proper Protection cont’dAddition, we recommend the following Emergency Evacuation Maintaining Your System Replacing Batteries in Wireless SensorsTaking Care of Your System Maintaining Your System cont’d Silencing Low Battery Warning Tones at the KeypadRoutine Care Quick Guide to System Functions Function Procedure CommentsAM/PM Quick Guide to System Functions cont’dAlpha Display Keypads Summary of Audible NotificationIndustry Canada Class B Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Index Access Another PartitionPOWER/READY Indicator ÊK5895V5*Š
Related manuals
Manual 80 pages 60.27 Kb

VISTA-128BP, VISTA-128SIA, VISTA-250BP specifications

The Honeywell VISTA-250BP and VISTA-128BP are advanced security control panels designed to provide robust protection for residential and commercial properties. These systems are part of Honeywell's VISTA series, known for their reliability and scalability, making them ideal for various applications.

One of the main features of the VISTA-250BP is its ability to support larger installations, accommodating up to 250 zones of security. This makes it an excellent choice for expansive properties or businesses that require comprehensive coverage. The VISTA-128BP is suited for smaller installations, providing support for up to 128 zones. Both panels offer flexibility in security device integration, allowing users to customize their security solutions according to their needs.

In terms of communication technologies, both panels are equipped with Honeywell's advanced encryption capabilities, ensuring that data transmission remains secure and protected from unauthorized access. They support a range of communication options, including Honeywell Total Connect, which allows users to monitor and control their security systems remotely via smartphones, tablets, or web browsers. This feature enhances convenience and responsiveness, especially for users who are frequently on the move.

Additionally, the VISTA-250BP and VISTA-128BP offer support for both wired and wireless security devices. This dual compatibility facilitates easier installations and makes it simpler for users to expand their security measures as their needs evolve. Users can seamlessly integrate devices such as door contacts, motion detectors, smoke detectors, and cameras, creating a comprehensive security blanket for their property.

Another notable characteristic of these panels is their user-friendly interface. The systems come equipped with a clear LCD display that provides real-time information and status updates, making it easy for users to navigate through various functions. Furthermore, the panels support multiple user codes, allowing different users to access the system with personalized access levels, enhancing overall security management.

Overall, the Honeywell VISTA-250BP and VISTA-128BP offer state-of-the-art security features, advanced communication technologies, and exceptional flexibility, making them ideal choices for both residential and commercial applications. Their scalability, user-friendly interfaces, and robust encryption capabilities ensure they meet the evolving needs of modern security demands.