Honeywell VISTA-250BP manual Bypassing Protection Zones, Using the 6 Bypass Key, Quick Bypass

Page 33

Bypassing Protection Zones

Using the 6 BYPASS Key

This key is used when you want to arm your system with one or more zones intentionally unprotected. Bypassed zones are unprotected and will not cause an alarm when violated while your system is armed. All bypasses are removed when an OFF sequence (security code plus OFF) is performed. Bypasses are also removed if the arming procedure that follows the bypass command is not successful.

Note: The system will not allow fire or emergency zones to be bypassed.

To bypass zones, the system must be disarmed first.

BYPASS

1. Enter your security code and press

6

.

2.Enter zone number(s) for the zones to be bypassed (e.g., 001, 002, 003, etc.). Important! All single-digit numbers must be preceded by “00” (for example, enter

001for zone 1).

3.Press [] + [].

4.

BYPASS 007 FRONT UPSTAIRS BEDROOM

Typical bypass message

When finished, the keypad will display the word BYPASS along with each bypassed zone number. Wait for these zones to be displayed before arming. Arming the system before bypassed zones are displayed eliminates all bypasses.

5.

DISARMED BYPASS

READY TO ARM

Arm the system as usual when the keypad displays "ready" to arm message.

Quick Bypass

Your system allows you to easily bypass all open (faulted) zones without having to enter zone numbers individually.

NOTE: All bypasses are removed when an OFF sequence (security code plus OFF) is performed.

To use the Quick Bypass feature:

BYPASS

1. Enter your security code and press

6

then press

#

.

– 33 –

Image 33
Contents VISTA-128BP/VISTA-250BP/ VISTA-128SIA Page Table of Contents Access Door Control Viewing Alarm CompanyUsing #70 Relay Menu Mode Programming Device TimersGeneral System OverviewPartitioned System System Overview cont’dPanel Linking ZonesAlarms Burglary ProtectionCarbon Monoxide Protection Using Schedules Memory of AlarmDevice Timers To Access another Partition Goto CommandPhone Access & Voice Response Capability Self-Help FeatureMaster Keypad Operation To view the abbreviated instructionsAlpha Keypad About The KeypadsFunction Keys LCD Display Functions of the KeypadRemoves Individual Functions of the Keypad cont’dFunctions of the Keypad cont’d General Information Entry/Exit DelaysSecurity Codes and Authority Levels Duress CodeQuick Arming Security Codes and Authority Levels cont’d Authority LevelsTo view your authority level and system capabilities General Rules on Authority Levels and Changes To Exit User Edit ModeCode To Add a UserMULTI-ACCESS ? 0 = no , 1 = YES To Change a Users Code To Delete a User To Access another Partition Accessing Other PartitionsGlobal Arming To Goto another partitionAccessing Other Partitions cont’d SystemStatus Fault 002 Loading Dock Window Whse Disarmed HIT for FaultsCommon Lobby Operation Codes with Global Arming How User Codes Affect the Common LobbyCodes with Non-Global Arming Other Methods of Arming/DisarmingSingle-Partition Single-Panel Mode Accessing Other PanelsMulti-Partition Multi-Panel Mode Accessing Other Panels cont’dMulti-Panel View Mode Priority Description Display To show faulted zones Using Ready KeyTypical fault display Checking For Open ZonesDisplaying All Zone Descriptors Using the 6 Bypass Key Bypassing Protection ZonesQuick Bypass Bypassing Protection Zones cont’d Viewing Bypassed ZonesGroup Bypass Zones Remaining Bypassed After Disarming Using the 3 Stay key Arming Perimeter OnlyArmed ***STAY Zone Bypassed Auto-STAY Arming With Entry Delay on cont’dArmed *INSTANT1 Zone Bypassed Using the 7 Instant KeyUsing Away Key Arming All ProtectionArmed **AWAY YOU MAY Exit NOW Armed *MAXIMUM* YOU MAY Exit NOW Using the 4 Maximum KeyUsing the # + 9 Keys Quick ExitTo Quick Exit the premises Using the 1 OFF Key Disarming and Silencing AlarmsTo disarm the system and silence burglary or fire alarms Disarmed Ready to ARMArming Using the KeyswitchDisarming To arm in the Stay mode, turnUsing Key Chime ModeChime Mode on Chime Mode OFFMESSAGE. Press For 5 Secs Viewing Alarm Company MessagesPanic Keys Using Panic KeysSpeed Key Macros DefiningEnter Speed KEY # Speed Key Macros cont’d ExecutingEnter User Code Access Door Control Enter Device no Using #70 Relay Menu ModeDelaying the Closing Time Using SchedulesClosing DELAY? KEY 0-2 Hours Temporary Open/Close SchedulesProgramming Temporary Schedules Using Schedules cont’dTo program temporary schedules MON Disarm Wind AM 0845AM MON ARM Window 0745AM 0845AMDays ? Mtwtfss HIT 0-7 X Programming Device Timers To enter the device timer menu modePorch Lite Enter OUTPUT# DAYS? Mtwtfss HIT 0-7 X Permanent ? Programming Device Timers cont’dRandomize Output Device Times Action Code Action Specifier Using #77 Instant Activation ModeBypass Commands Using #77 Instant Activation Mode cont’dAction ? Are YOU Sure ? To enter the Instant Activation ModeQuit Menu MODE? Zone List ?Enter Code + # + 6 + Select the display mode Event Log ProceduresSelect the partition To Exit the Event Log Press at any timeTIME/DATE Setting the Time and DateTesting Your System Using Test KeyCase Of Fire Alarm Fire Alarm SystemSilencing a Fire Alarm Fire Display LockTypical Trouble Displays Trouble ConditionsTrouble Conditions cont’d Power FailureRecommendations for Smoke and Heat Detectors Recommendations for Proper ProtectionRecommendations for Proper Protection cont’d Recommendations for Proper Intrusion ProtectionAddition, we recommend the following Emergency Evacuation Replacing Batteries in Wireless Sensors Maintaining Your SystemTaking Care of Your System Silencing Low Battery Warning Tones at the Keypad Maintaining Your System cont’dRoutine Care Quick Guide to System Functions Function Procedure CommentsAM/PM Quick Guide to System Functions cont’dAlpha Display Keypads Summary of Audible NotificationIndustry Canada Class B Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Index Access Another PartitionPOWER/READY Indicator ÊK5895V5*Š
Related manuals
Manual 80 pages 60.27 Kb

VISTA-128BP, VISTA-128SIA, VISTA-250BP specifications

The Honeywell VISTA-250BP and VISTA-128BP are advanced security control panels designed to provide robust protection for residential and commercial properties. These systems are part of Honeywell's VISTA series, known for their reliability and scalability, making them ideal for various applications.

One of the main features of the VISTA-250BP is its ability to support larger installations, accommodating up to 250 zones of security. This makes it an excellent choice for expansive properties or businesses that require comprehensive coverage. The VISTA-128BP is suited for smaller installations, providing support for up to 128 zones. Both panels offer flexibility in security device integration, allowing users to customize their security solutions according to their needs.

In terms of communication technologies, both panels are equipped with Honeywell's advanced encryption capabilities, ensuring that data transmission remains secure and protected from unauthorized access. They support a range of communication options, including Honeywell Total Connect, which allows users to monitor and control their security systems remotely via smartphones, tablets, or web browsers. This feature enhances convenience and responsiveness, especially for users who are frequently on the move.

Additionally, the VISTA-250BP and VISTA-128BP offer support for both wired and wireless security devices. This dual compatibility facilitates easier installations and makes it simpler for users to expand their security measures as their needs evolve. Users can seamlessly integrate devices such as door contacts, motion detectors, smoke detectors, and cameras, creating a comprehensive security blanket for their property.

Another notable characteristic of these panels is their user-friendly interface. The systems come equipped with a clear LCD display that provides real-time information and status updates, making it easy for users to navigate through various functions. Furthermore, the panels support multiple user codes, allowing different users to access the system with personalized access levels, enhancing overall security management.

Overall, the Honeywell VISTA-250BP and VISTA-128BP offer state-of-the-art security features, advanced communication technologies, and exceptional flexibility, making them ideal choices for both residential and commercial applications. Their scalability, user-friendly interfaces, and robust encryption capabilities ensure they meet the evolving needs of modern security demands.