Security Codes & Authority Levels

General Information

At the time of installation, you were assigned an authority level and a personal four-digit security code, known only to you and yours. The security code must be entered when arming and disarming the system. The authority level defines the system functions that you can perform.

As an additional safety feature, other users that do not have a need to know your code can be assigned different security codes, and each user can be given a different authority level. Users are identified by "user numbers", which are assigned when assigning a user's security code.

All codes can be used interchangeably when performing system functions within the limits of each code's authority level (a system armed with one user's code can be disarmed by another user's code), with the exception of the Operator Level C code. See AUTHORITY LEVELS on the following page for details regarding authority levels.

Important: Only users assigned for user numbers 001-050 can perform panel linking functions.

Duress Code

This feature is intended for use if you are forced to disarm or arm the system under threat. When used, the system will act normally, but can silently notify the central station of your situation, if that service has been provided. The duress code is pre-assigned by the installer during installation (authority level 6).

Important: This code is useful only when the system is connected to a central station.

Quick Arming

Note that if "Quick Arming" was programmed by the installer, the [#] key can be pressed in place of the security code when arming the system. The security code must always be used to disarm the system, however.

– 15 –

Image 15
Contents 67$%3 Page Table of Contents Setting the Time and Date Using #70 Relay Menu ModeProgramming Device Timers Using #77 Instant ActivationGeneral System OverviewZones System Overview cont’dPartitioned System Panel LinkingAlarms Memory of AlarmBurglary Protection Speed Key Macros Using SchedulesDevice Timers To Access Another Partition Goto CommandTo view the abbreviated instructions Self-Help FeaturePhone Access & Voice Response Capability Master Keypad OperationAlpha Keypad About The KeypadsFunction Keys LCD Display Functions Of The KeypadRemoves Individual Functions Of The Keypad cont’dFunctions Of The Keypad cont’d General Information Entry/Exit DelaysSecurity Codes & Authority Levels Duress CodeQuick Arming Security Codes & Authority Levels cont’d Authority LevelsTo view your authority level and system capabilities General Rules on Authority Levels and Changes To Exit User Edit ModeCode To Add a UserMULTI-ACCESS ? 0 = no , 1 = YES To Change a Users Code To Delete a User To Goto another partition Accessing Other PartitionsTo Access Another Partition Global ArmingAccessing Other Partitions cont’d SystemStatus Fault 002 Loading Dock Window Whse Disarmed HIT for FaultsCommon Lobby Operation Other Methods of Arming/Disarming How User Codes Affect the Common LobbyCodes with Global Arming Codes with Non-Global ArmingSingle-Partition Single-Panel Mode Accessing Other PanelsMulti-Partition Multi-Panel Mode Accessing Other Panels cont’dMulti-Panel View Mode Priority Description Display Typical fault display Using Ready KeyTo show faulted zones Fault 005 Front Upstairs Bedroom Disarmed Ready to ARMDisplaying All Zone Descriptors Bypass 007 Front Upstairs Bedroom Using Bypass KeyBypassing Protection Zones To bypass zones, the system must be disarmed firstDisplaying Bypassed Zones To use the Quick Bypass featureBypassing Protection Zones cont’d Quick BypassGroup Bypass To use the Group Bypass featureUsing the 3 Stay key Arming Perimeter OnlyArmed ***STAY Zone Bypassed Auto-STAY Arming With Entry Delay on cont’dArmed *INSTANT1 Zone Bypassed Using the 7 Instant KeyUsing Away Key Arming All ProtectionArmed **AWAY YOU MAY Exit NOW Armed *MAXIMUM* YOU MAY Exit NOW Using the 4 Maximum KeyUsing the # + 9 Keys Quick ExitTo Quick Exit the premises Disarmed Ready to ARM Disarming And Silencing AlarmsUsing the 1 OFF Key To disarm the system and silence burglary or fire alarmsUsing The Keyswitch ArmingDisarming Chime Mode OFF Chime ModeUsing Key Chime Mode onMESSAGE. Press For 5 Secs Viewing Alarm Company MessagesPanic Keys Using Panic KeysSpeed Key Macros DefiningEnter Speed KEY # Speed Key Macros cont’d ExecutingEnter User Code Access Door Control Enter Device no Using #70 Relay Menu ModeTemporary Open/Close Schedules Using SchedulesDelaying the Closing Time Closing DELAY? KEY 0-2 HoursUsing Schedules cont’d Programming Temporary SchedulesTo program temporary schedules Days ? Mtwtfss HIT 0-7 X Programming Device Timers To enter the device timer menu modePorch Lite Enter OUTPUT# DAYS? Mtwtfss HIT 0-7 X Permanent ? Programming Device Timers cont’dRandomize Output Device Times Action Code Action Specifier Using #77 Instant Activation ModeBypass Commands Using #77 Instant Activation Mode cont’dZone List ? To enter the Instant Activation ModeAction ? Are YOU Sure ? Quit Menu MODE?To Exit the Event Log Press at any time Event Log ProceduresEnter Code + # + 6 + Select the display mode Select the partitionEvent Logging Procedures Setting the Time and DateTIME/DATE Testing Your System Using Test KeyFire Display Lock Fire Alarm SystemCase Of Fire Alarm Silencing a Fire AlarmTypical Trouble Displays Trouble ConditionsTrouble Conditions cont’d Power FailureRecommendations For Smoke And Heat Detectors Recommendations For Proper ProtectionRecommendations For Proper Protection cont’d Recommendations For Proper Intrusion ProtectionAddition, we recommend the following Emergency Evacuation Replacing Batteries in Wireless Sensors Maintaining Your SystemTaking Care of Your System Silencing Low Battery Warning Tones at the Keypad Maintaining Your System cont’dRoutine Care Quick Guide To System Functions Function Procedure CommentsAM/PM Quick Guide To System Functions cont’dAlpha Display Keypads Summary Of Audible NotificationFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Advanced User Interface IndexNfpa Night ¬.9l
Related manuals
Manual 80 pages 59.71 Kb

VISTA-128BP, VISTA-250BP specifications

The Honeywell VISTA-250BP and VISTA-128BP are advanced security control panels designed to provide robust protection for residential and commercial properties. These systems are part of Honeywell's VISTA series, known for their reliability and scalability, making them ideal for various applications.

One of the main features of the VISTA-250BP is its ability to support larger installations, accommodating up to 250 zones of security. This makes it an excellent choice for expansive properties or businesses that require comprehensive coverage. The VISTA-128BP is suited for smaller installations, providing support for up to 128 zones. Both panels offer flexibility in security device integration, allowing users to customize their security solutions according to their needs.

In terms of communication technologies, both panels are equipped with Honeywell's advanced encryption capabilities, ensuring that data transmission remains secure and protected from unauthorized access. They support a range of communication options, including Honeywell Total Connect, which allows users to monitor and control their security systems remotely via smartphones, tablets, or web browsers. This feature enhances convenience and responsiveness, especially for users who are frequently on the move.

Additionally, the VISTA-250BP and VISTA-128BP offer support for both wired and wireless security devices. This dual compatibility facilitates easier installations and makes it simpler for users to expand their security measures as their needs evolve. Users can seamlessly integrate devices such as door contacts, motion detectors, smoke detectors, and cameras, creating a comprehensive security blanket for their property.

Another notable characteristic of these panels is their user-friendly interface. The systems come equipped with a clear LCD display that provides real-time information and status updates, making it easy for users to navigate through various functions. Furthermore, the panels support multiple user codes, allowing different users to access the system with personalized access levels, enhancing overall security management.

Overall, the Honeywell VISTA-250BP and VISTA-128BP offer state-of-the-art security features, advanced communication technologies, and exceptional flexibility, making them ideal choices for both residential and commercial applications. Their scalability, user-friendly interfaces, and robust encryption capabilities ensure they meet the evolving needs of modern security demands.