Honeywell VISTA-250BP, VISTA-128BP manual To Add a User, Code

Page 18

Security Codes & Authority Levels (cont’d)

To Add a User

IMPORTANT: Temporary users should not be shown how to use any system function they do not need to know (e.g. bypassing protection zones).

CODE

1. Enter Master or Manager code and press the

8

key.

2.Enter the new user's 3-digit User Number (002-250).

3.Enter 4-digit security code for that user. The following prompts will appear.

ADD NEW USER? 0 = NO , 1 = YES

USER NUMBER = 003

ENTER AUTH. LEVEL

Enter 1 to add a new user code. Entering 0 will change the existing user's code to the code entered in step 3. See Changing A User's Code section.

Enter the authority level, 1-6, for this user within

this partition.

 

 

1=master

2=manager

3=operator A

4=operator B

5=operator C

6=duress code

GROUP BYPASSING? 0 = NO , 1 = YES

ACCESS GROUP? ENTER 0-8

RF BUTTON ?

0 = NO , 1 = YES

Enter 1 (YES) to allow this user to perform group bypasses. Enter 0 (NO) this user will not be able to perform group bypasses.

If access schedules have been programmed, this prompt appears. Enter the user's access group number (1-8) if this user should have limited access to the system. Enter 0 if no access group should be assigned.

This prompt will appear if a 5800 series button transmitter has been supplied and has not yet been assigned to a user. Press 1 if a button transmitter will be assigned to this user. Otherwise press 0.

ENTER BUTTON ZN # (001-250)

If assigning a button transmitter, this prompt will appear. Enter the button's zone number (see your installer for zone number).

– 18 –

Image 18
Contents 67$%3 Page Table of Contents Using #77 Instant Activation Using #70 Relay Menu ModeProgramming Device Timers Setting the Time and DateSystem Overview GeneralPanel Linking System Overview cont’dPartitioned System ZonesAlarms Memory of AlarmBurglary Protection To Access Another Partition Goto Command Using SchedulesDevice Timers Speed Key MacrosMaster Keypad Operation Self-Help FeaturePhone Access & Voice Response Capability To view the abbreviated instructionsAbout The Keypads Alpha KeypadFunctions Of The Keypad Function Keys LCD DisplayFunctions Of The Keypad cont’d Removes IndividualFunctions Of The Keypad cont’d Entry/Exit Delays General InformationSecurity Codes & Authority Levels Duress CodeQuick Arming Security Codes & Authority Levels cont’d Authority LevelsTo view your authority level and system capabilities To Exit User Edit Mode General Rules on Authority Levels and ChangesTo Add a User CodeMULTI-ACCESS ? 0 = no , 1 = YES To Change a Users Code To Delete a User Global Arming Accessing Other PartitionsTo Access Another Partition To Goto another partitionAccessing Other Partitions cont’d SystemStatus Whse Disarmed HIT for Faults Fault 002 Loading Dock WindowCommon Lobby Operation Codes with Non-Global Arming How User Codes Affect the Common LobbyCodes with Global Arming Other Methods of Arming/DisarmingAccessing Other Panels Single-Partition Single-Panel ModeAccessing Other Panels cont’d Multi-Partition Multi-Panel ModeMulti-Panel View Mode Priority Description Display Fault 005 Front Upstairs Bedroom Disarmed Ready to ARM Using Ready KeyTo show faulted zones Typical fault displayDisplaying All Zone Descriptors To bypass zones, the system must be disarmed first Using Bypass KeyBypassing Protection Zones Bypass 007 Front Upstairs BedroomQuick Bypass To use the Quick Bypass featureBypassing Protection Zones cont’d Displaying Bypassed ZonesTo use the Group Bypass feature Group BypassUsing the 3 Stay key Arming Perimeter OnlyArmed ***STAY Zone Bypassed With Entry Delay on cont’d Auto-STAY ArmingUsing the 7 Instant Key Armed *INSTANT1 Zone BypassedUsing Away Key Arming All ProtectionArmed **AWAY YOU MAY Exit NOW Using the 4 Maximum Key Armed *MAXIMUM* YOU MAY Exit NOWUsing the # + 9 Keys Quick ExitTo Quick Exit the premises To disarm the system and silence burglary or fire alarms Disarming And Silencing AlarmsUsing the 1 OFF Key Disarmed Ready to ARMUsing The Keyswitch ArmingDisarming Chime Mode on Chime ModeUsing Key Chime Mode OFFViewing Alarm Company Messages MESSAGE. Press For 5 SecsUsing Panic Keys Panic KeysSpeed Key Macros DefiningEnter Speed KEY # Speed Key Macros cont’d ExecutingEnter User Code Access Door Control Using #70 Relay Menu Mode Enter Device noClosing DELAY? KEY 0-2 Hours Using SchedulesDelaying the Closing Time Temporary Open/Close SchedulesUsing Schedules cont’d Programming Temporary SchedulesTo program temporary schedules Days ? Mtwtfss HIT 0-7 X Programming Device Timers To enter the device timer menu modePorch Lite Enter OUTPUT# Programming Device Timers cont’d DAYS? Mtwtfss HIT 0-7 X Permanent ?Randomize Output Device Times Using #77 Instant Activation Mode Action Code Action SpecifierUsing #77 Instant Activation Mode cont’d Bypass CommandsQuit Menu MODE? To enter the Instant Activation ModeAction ? Are YOU Sure ? Zone List ?Select the partition Event Log ProceduresEnter Code + # + 6 + Select the display mode To Exit the Event Log Press at any timeEvent Logging Procedures Setting the Time and DateTIME/DATE Using Test Key Testing Your SystemSilencing a Fire Alarm Fire Alarm SystemCase Of Fire Alarm Fire Display LockTrouble Conditions Typical Trouble DisplaysPower Failure Trouble Conditions cont’dRecommendations For Proper Protection Recommendations For Smoke And Heat DetectorsRecommendations For Proper Protection cont’d Recommendations For Proper Intrusion ProtectionAddition, we recommend the following Emergency Evacuation Replacing Batteries in Wireless Sensors Maintaining Your SystemTaking Care of Your System Silencing Low Battery Warning Tones at the Keypad Maintaining Your System cont’dRoutine Care Function Procedure Comments Quick Guide To System FunctionsQuick Guide To System Functions cont’d AM/PMSummary Of Audible Notification Alpha Display KeypadsFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Index Advanced User InterfaceNfpa Night ¬.9l
Related manuals
Manual 80 pages 59.71 Kb

VISTA-128BP, VISTA-250BP specifications

The Honeywell VISTA-250BP and VISTA-128BP are advanced security control panels designed to provide robust protection for residential and commercial properties. These systems are part of Honeywell's VISTA series, known for their reliability and scalability, making them ideal for various applications.

One of the main features of the VISTA-250BP is its ability to support larger installations, accommodating up to 250 zones of security. This makes it an excellent choice for expansive properties or businesses that require comprehensive coverage. The VISTA-128BP is suited for smaller installations, providing support for up to 128 zones. Both panels offer flexibility in security device integration, allowing users to customize their security solutions according to their needs.

In terms of communication technologies, both panels are equipped with Honeywell's advanced encryption capabilities, ensuring that data transmission remains secure and protected from unauthorized access. They support a range of communication options, including Honeywell Total Connect, which allows users to monitor and control their security systems remotely via smartphones, tablets, or web browsers. This feature enhances convenience and responsiveness, especially for users who are frequently on the move.

Additionally, the VISTA-250BP and VISTA-128BP offer support for both wired and wireless security devices. This dual compatibility facilitates easier installations and makes it simpler for users to expand their security measures as their needs evolve. Users can seamlessly integrate devices such as door contacts, motion detectors, smoke detectors, and cameras, creating a comprehensive security blanket for their property.

Another notable characteristic of these panels is their user-friendly interface. The systems come equipped with a clear LCD display that provides real-time information and status updates, making it easy for users to navigate through various functions. Furthermore, the panels support multiple user codes, allowing different users to access the system with personalized access levels, enhancing overall security management.

Overall, the Honeywell VISTA-250BP and VISTA-128BP offer state-of-the-art security features, advanced communication technologies, and exceptional flexibility, making them ideal choices for both residential and commercial applications. Their scalability, user-friendly interfaces, and robust encryption capabilities ensure they meet the evolving needs of modern security demands.