System Overview (cont’d)

Burglary Protection

The burglary protection portion of your system must be turned on or "armed" before it will sense burglary alarm conditions. Your system provides four modes of burglary protection: STAY, AWAY, INSTANT and MAXIMUM, and even allows you to BYPASS selected zones of protection while leaving the rest of the system armed. The system also provides a CHIME mode, for alerting users to the opening and closing of doors and windows while the system is disarmed. Refer to the other sections of this manual for procedures for using these features.

The following table lists the four different arming modes and the results of each.

 

Features For Each Arming Mode

Arming

Exit

Entry

Perimeter

Mode

Delay

Delay

Armed

AWAY

Yes

Yes

Yes

STAY

Yes

Yes

Yes

INSTANT

Yes

No

Yes

MAXIMUM

Yes

No

Yes

The system provides three different STAY and INSTANT arming modes. See ARMING IN THE STAY MODES and ARMING IN THE INSTANT MODES sections for details on these modes.

Alarms

When an alarm occurs, both the keypad and external sounders will sound, and the keypad will display the zone(s) causing the alarm. If your system is connected to a central monitoring station, an alarm message will also be sent. To stop the alarm sounding, simply disarm the system.

Memory of Alarm

When an alarm condition occurs, the keypad displays the number(s) of the zone(s) that caused the problem, and displays the type of alarm (ex. FIRE, ALARM). It remains displayed until it is cleared by disarming the system (see DISARMING THE SYSTEM section).

– 7 –

Image 7
Contents 67$%3 Page Table of Contents Setting the Time and Date Using #70 Relay Menu ModeProgramming Device Timers Using #77 Instant ActivationGeneral System OverviewZones System Overview cont’dPartitioned System Panel LinkingMemory of Alarm AlarmsBurglary Protection Speed Key Macros Using SchedulesDevice Timers To Access Another Partition Goto CommandTo view the abbreviated instructions Self-Help FeaturePhone Access & Voice Response Capability Master Keypad OperationAlpha Keypad About The KeypadsFunction Keys LCD Display Functions Of The KeypadRemoves Individual Functions Of The Keypad cont’dFunctions Of The Keypad cont’d General Information Entry/Exit DelaysDuress Code Security Codes & Authority LevelsQuick Arming Authority Levels Security Codes & Authority Levels cont’dTo view your authority level and system capabilities General Rules on Authority Levels and Changes To Exit User Edit ModeCode To Add a UserMULTI-ACCESS ? 0 = no , 1 = YES To Change a Users Code To Delete a User To Goto another partition Accessing Other PartitionsTo Access Another Partition Global ArmingSystem Accessing Other Partitions cont’dStatus Fault 002 Loading Dock Window Whse Disarmed HIT for FaultsCommon Lobby Operation Other Methods of Arming/Disarming How User Codes Affect the Common LobbyCodes with Global Arming Codes with Non-Global ArmingSingle-Partition Single-Panel Mode Accessing Other PanelsMulti-Partition Multi-Panel Mode Accessing Other Panels cont’dMulti-Panel View Mode Priority Description Display Typical fault display Using Ready KeyTo show faulted zones Fault 005 Front Upstairs Bedroom Disarmed Ready to ARMDisplaying All Zone Descriptors Bypass 007 Front Upstairs Bedroom Using Bypass KeyBypassing Protection Zones To bypass zones, the system must be disarmed firstDisplaying Bypassed Zones To use the Quick Bypass featureBypassing Protection Zones cont’d Quick BypassGroup Bypass To use the Group Bypass featureArming Perimeter Only Using the 3 Stay keyArmed ***STAY Zone Bypassed Auto-STAY Arming With Entry Delay on cont’dArmed *INSTANT1 Zone Bypassed Using the 7 Instant KeyArming All Protection Using Away KeyArmed **AWAY YOU MAY Exit NOW Armed *MAXIMUM* YOU MAY Exit NOW Using the 4 Maximum KeyQuick Exit Using the # + 9 KeysTo Quick Exit the premises Disarmed Ready to ARM Disarming And Silencing AlarmsUsing the 1 OFF Key To disarm the system and silence burglary or fire alarmsArming Using The KeyswitchDisarming Chime Mode OFF Chime ModeUsing Key Chime Mode onMESSAGE. Press For 5 Secs Viewing Alarm Company MessagesPanic Keys Using Panic KeysDefining Speed Key MacrosEnter Speed KEY # Executing Speed Key Macros cont’dEnter User Code Access Door Control Enter Device no Using #70 Relay Menu ModeTemporary Open/Close Schedules Using SchedulesDelaying the Closing Time Closing DELAY? KEY 0-2 HoursProgramming Temporary Schedules Using Schedules cont’dTo program temporary schedules Days ? Mtwtfss HIT 0-7 X To enter the device timer menu mode Programming Device TimersPorch Lite Enter OUTPUT# DAYS? Mtwtfss HIT 0-7 X Permanent ? Programming Device Timers cont’dRandomize Output Device Times Action Code Action Specifier Using #77 Instant Activation ModeBypass Commands Using #77 Instant Activation Mode cont’dZone List ? To enter the Instant Activation ModeAction ? Are YOU Sure ? Quit Menu MODE?To Exit the Event Log Press at any time Event Log ProceduresEnter Code + # + 6 + Select the display mode Select the partitionSetting the Time and Date Event Logging ProceduresTIME/DATE Testing Your System Using Test KeyFire Display Lock Fire Alarm SystemCase Of Fire Alarm Silencing a Fire AlarmTypical Trouble Displays Trouble ConditionsTrouble Conditions cont’d Power FailureRecommendations For Smoke And Heat Detectors Recommendations For Proper ProtectionRecommendations For Proper Intrusion Protection Recommendations For Proper Protection cont’dAddition, we recommend the following Emergency Evacuation Maintaining Your System Replacing Batteries in Wireless SensorsTaking Care of Your System Maintaining Your System cont’d Silencing Low Battery Warning Tones at the KeypadRoutine Care Quick Guide To System Functions Function Procedure CommentsAM/PM Quick Guide To System Functions cont’dAlpha Display Keypads Summary Of Audible NotificationFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Advanced User Interface IndexNfpa Night ¬.9l
Related manuals
Manual 80 pages 59.71 Kb

VISTA-128BP, VISTA-250BP specifications

The Honeywell VISTA-250BP and VISTA-128BP are advanced security control panels designed to provide robust protection for residential and commercial properties. These systems are part of Honeywell's VISTA series, known for their reliability and scalability, making them ideal for various applications.

One of the main features of the VISTA-250BP is its ability to support larger installations, accommodating up to 250 zones of security. This makes it an excellent choice for expansive properties or businesses that require comprehensive coverage. The VISTA-128BP is suited for smaller installations, providing support for up to 128 zones. Both panels offer flexibility in security device integration, allowing users to customize their security solutions according to their needs.

In terms of communication technologies, both panels are equipped with Honeywell's advanced encryption capabilities, ensuring that data transmission remains secure and protected from unauthorized access. They support a range of communication options, including Honeywell Total Connect, which allows users to monitor and control their security systems remotely via smartphones, tablets, or web browsers. This feature enhances convenience and responsiveness, especially for users who are frequently on the move.

Additionally, the VISTA-250BP and VISTA-128BP offer support for both wired and wireless security devices. This dual compatibility facilitates easier installations and makes it simpler for users to expand their security measures as their needs evolve. Users can seamlessly integrate devices such as door contacts, motion detectors, smoke detectors, and cameras, creating a comprehensive security blanket for their property.

Another notable characteristic of these panels is their user-friendly interface. The systems come equipped with a clear LCD display that provides real-time information and status updates, making it easy for users to navigate through various functions. Furthermore, the panels support multiple user codes, allowing different users to access the system with personalized access levels, enhancing overall security management.

Overall, the Honeywell VISTA-250BP and VISTA-128BP offer state-of-the-art security features, advanced communication technologies, and exceptional flexibility, making them ideal choices for both residential and commercial applications. Their scalability, user-friendly interfaces, and robust encryption capabilities ensure they meet the evolving needs of modern security demands.