Using #77 Instant Activation Mode (cont’d)

Bypass Commands

Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid choices for bypass commands. If 3 (During) is selected for auto-bypassing, the system bypasses the zone(s) specified on a particular zone list at the beginning of the window and unbypasses them at the end of the window. If it is selected for auto unbypassing, the system removes the bypass at the beginning of the window and restores the bypass at the end of the window.

Action Code

Action Specifier

30

Auto bypass - Zone list

Zone list #

31

Auto unbypass - Zone list

Zone list #

Open/Close Windows

Activation time 3 (During) is the only valid choice for these commands.

Action Code

Action Specifier

40

Enable Opening Window by partition

Partition(s)

41

Enable Closing Window by partition

Partition(s)

42

Enable Access Window for access group

Access Group

Access Control Commands

 

Action Code

Action Specifier

55

Access Point Grant

Access Point #

56

Access Point Grant with Override

Access Point #

57

Access Point Protect

Access Point #

58

Access Point Bypass

Access Point #

59

Access Point Lock

Access Point #

60

Access Point Exit

Access Point #

61

Access Point Group Grant

Group #

62

Access Point Group Grant with Override

Group #

63

Access Point Group Protect

Group #

64

Access Point Group Bypass

Group #

66

Access Point Group Exit

Group #

67

Access Point Partition Grant

Partition #

68

Access Point Partition Grant with Override

Partition #

69

Access Point Protect by Partition

Partition #

70

Access Point Bypass by Partition

Partition #

71

Access Point Lock by Partition

Partition #

72

Access Point Exit by Partition

Partition #

73

Access Point Trigger On

Trigger #

74

Access Point Trigger Off

Trigger #

 

 

 

 

 

 

– 58 –

Image 58
Contents 67$%3 Page Table of Contents Using #77 Instant Activation Using #70 Relay Menu ModeProgramming Device Timers Setting the Time and DateSystem Overview GeneralPanel Linking System Overview cont’dPartitioned System ZonesMemory of Alarm AlarmsBurglary Protection To Access Another Partition Goto Command Using SchedulesDevice Timers Speed Key MacrosMaster Keypad Operation Self-Help FeaturePhone Access & Voice Response Capability To view the abbreviated instructionsAbout The Keypads Alpha KeypadFunctions Of The Keypad Function Keys LCD DisplayFunctions Of The Keypad cont’d Removes IndividualFunctions Of The Keypad cont’d Entry/Exit Delays General InformationDuress Code Security Codes & Authority LevelsQuick Arming Authority Levels Security Codes & Authority Levels cont’dTo view your authority level and system capabilities To Exit User Edit Mode General Rules on Authority Levels and ChangesTo Add a User CodeMULTI-ACCESS ? 0 = no , 1 = YES To Change a Users Code To Delete a User Global Arming Accessing Other PartitionsTo Access Another Partition To Goto another partitionSystem Accessing Other Partitions cont’dStatus Whse Disarmed HIT for Faults Fault 002 Loading Dock WindowCommon Lobby Operation Codes with Non-Global Arming How User Codes Affect the Common LobbyCodes with Global Arming Other Methods of Arming/DisarmingAccessing Other Panels Single-Partition Single-Panel ModeAccessing Other Panels cont’d Multi-Partition Multi-Panel ModeMulti-Panel View Mode Priority Description Display Fault 005 Front Upstairs Bedroom Disarmed Ready to ARM Using Ready KeyTo show faulted zones Typical fault displayDisplaying All Zone Descriptors To bypass zones, the system must be disarmed first Using Bypass KeyBypassing Protection Zones Bypass 007 Front Upstairs BedroomQuick Bypass To use the Quick Bypass featureBypassing Protection Zones cont’d Displaying Bypassed ZonesTo use the Group Bypass feature Group BypassArming Perimeter Only Using the 3 Stay keyArmed ***STAY Zone Bypassed With Entry Delay on cont’d Auto-STAY ArmingUsing the 7 Instant Key Armed *INSTANT1 Zone BypassedArming All Protection Using Away KeyArmed **AWAY YOU MAY Exit NOW Using the 4 Maximum Key Armed *MAXIMUM* YOU MAY Exit NOWQuick Exit Using the # + 9 KeysTo Quick Exit the premises To disarm the system and silence burglary or fire alarms Disarming And Silencing AlarmsUsing the 1 OFF Key Disarmed Ready to ARMArming Using The KeyswitchDisarming Chime Mode on Chime ModeUsing Key Chime Mode OFFViewing Alarm Company Messages MESSAGE. Press For 5 SecsUsing Panic Keys Panic KeysDefining Speed Key MacrosEnter Speed KEY # Executing Speed Key Macros cont’dEnter User Code Access Door Control Using #70 Relay Menu Mode Enter Device noClosing DELAY? KEY 0-2 Hours Using SchedulesDelaying the Closing Time Temporary Open/Close SchedulesProgramming Temporary Schedules Using Schedules cont’dTo program temporary schedules Days ? Mtwtfss HIT 0-7 X To enter the device timer menu mode Programming Device TimersPorch Lite Enter OUTPUT# Programming Device Timers cont’d DAYS? Mtwtfss HIT 0-7 X Permanent ?Randomize Output Device Times Using #77 Instant Activation Mode Action Code Action SpecifierUsing #77 Instant Activation Mode cont’d Bypass CommandsQuit Menu MODE? To enter the Instant Activation ModeAction ? Are YOU Sure ? Zone List ?Select the partition Event Log ProceduresEnter Code + # + 6 + Select the display mode To Exit the Event Log Press at any timeSetting the Time and Date Event Logging ProceduresTIME/DATE Using Test Key Testing Your SystemSilencing a Fire Alarm Fire Alarm SystemCase Of Fire Alarm Fire Display LockTrouble Conditions Typical Trouble DisplaysPower Failure Trouble Conditions cont’dRecommendations For Proper Protection Recommendations For Smoke And Heat DetectorsRecommendations For Proper Intrusion Protection Recommendations For Proper Protection cont’dAddition, we recommend the following Emergency Evacuation Maintaining Your System Replacing Batteries in Wireless SensorsTaking Care of Your System Maintaining Your System cont’d Silencing Low Battery Warning Tones at the KeypadRoutine Care Function Procedure Comments Quick Guide To System FunctionsQuick Guide To System Functions cont’d AM/PMSummary Of Audible Notification Alpha Display KeypadsFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Index Advanced User InterfaceNfpa Night ¬.9l
Related manuals
Manual 80 pages 59.71 Kb

VISTA-128BP, VISTA-250BP specifications

The Honeywell VISTA-250BP and VISTA-128BP are advanced security control panels designed to provide robust protection for residential and commercial properties. These systems are part of Honeywell's VISTA series, known for their reliability and scalability, making them ideal for various applications.

One of the main features of the VISTA-250BP is its ability to support larger installations, accommodating up to 250 zones of security. This makes it an excellent choice for expansive properties or businesses that require comprehensive coverage. The VISTA-128BP is suited for smaller installations, providing support for up to 128 zones. Both panels offer flexibility in security device integration, allowing users to customize their security solutions according to their needs.

In terms of communication technologies, both panels are equipped with Honeywell's advanced encryption capabilities, ensuring that data transmission remains secure and protected from unauthorized access. They support a range of communication options, including Honeywell Total Connect, which allows users to monitor and control their security systems remotely via smartphones, tablets, or web browsers. This feature enhances convenience and responsiveness, especially for users who are frequently on the move.

Additionally, the VISTA-250BP and VISTA-128BP offer support for both wired and wireless security devices. This dual compatibility facilitates easier installations and makes it simpler for users to expand their security measures as their needs evolve. Users can seamlessly integrate devices such as door contacts, motion detectors, smoke detectors, and cameras, creating a comprehensive security blanket for their property.

Another notable characteristic of these panels is their user-friendly interface. The systems come equipped with a clear LCD display that provides real-time information and status updates, making it easy for users to navigate through various functions. Furthermore, the panels support multiple user codes, allowing different users to access the system with personalized access levels, enhancing overall security management.

Overall, the Honeywell VISTA-250BP and VISTA-128BP offer state-of-the-art security features, advanced communication technologies, and exceptional flexibility, making them ideal choices for both residential and commercial applications. Their scalability, user-friendly interfaces, and robust encryption capabilities ensure they meet the evolving needs of modern security demands.