Honeywell VISTA-250BP, VISTA-128BP manual Displaying All Zone Descriptors

Page 32

Displaying All Zone Descriptors

Using the

READY Key

The Alpha Keypads can also display all the zone descriptors that are programmed in your system. The abbreviated instructions for the READY key will appear first, followed by the zone descriptors. Displaying all descriptors is useful when you need to know the zone number of a particular zone, as when bypassing zones.

The "Disarmed-Ready to arm" message must be displayed before zone

descriptors can be displayed.

 

READY

Press the

key and hold down for at least 5 seconds.

– 32 –

Image 32
Contents 67$%3 Page Table of Contents Using #70 Relay Menu Mode Programming Device TimersUsing #77 Instant Activation Setting the Time and DateSystem Overview GeneralSystem Overview cont’d Partitioned SystemPanel Linking ZonesBurglary Protection AlarmsMemory of Alarm Using Schedules Device TimersTo Access Another Partition Goto Command Speed Key MacrosSelf-Help Feature Phone Access & Voice Response CapabilityMaster Keypad Operation To view the abbreviated instructionsAbout The Keypads Alpha KeypadFunctions Of The Keypad Function Keys LCD DisplayFunctions Of The Keypad cont’d Removes IndividualFunctions Of The Keypad cont’d Entry/Exit Delays General InformationQuick Arming Security Codes & Authority LevelsDuress Code To view your authority level and system capabilities Security Codes & Authority Levels cont’dAuthority Levels To Exit User Edit Mode General Rules on Authority Levels and ChangesTo Add a User CodeMULTI-ACCESS ? 0 = no , 1 = YES To Change a Users Code To Delete a User Accessing Other Partitions To Access Another PartitionGlobal Arming To Goto another partitionStatus Accessing Other Partitions cont’dSystem Whse Disarmed HIT for Faults Fault 002 Loading Dock WindowCommon Lobby Operation How User Codes Affect the Common Lobby Codes with Global ArmingCodes with Non-Global Arming Other Methods of Arming/DisarmingAccessing Other Panels Single-Partition Single-Panel ModeAccessing Other Panels cont’d Multi-Partition Multi-Panel ModeMulti-Panel View Mode Priority Description Display Using Ready Key To show faulted zonesFault 005 Front Upstairs Bedroom Disarmed Ready to ARM Typical fault displayDisplaying All Zone Descriptors Using Bypass Key Bypassing Protection ZonesTo bypass zones, the system must be disarmed first Bypass 007 Front Upstairs BedroomTo use the Quick Bypass feature Bypassing Protection Zones cont’dQuick Bypass Displaying Bypassed ZonesTo use the Group Bypass feature Group BypassArmed ***STAY Zone Bypassed Using the 3 Stay keyArming Perimeter Only With Entry Delay on cont’d Auto-STAY ArmingUsing the 7 Instant Key Armed *INSTANT1 Zone BypassedArmed **AWAY YOU MAY Exit NOW Using Away KeyArming All Protection Using the 4 Maximum Key Armed *MAXIMUM* YOU MAY Exit NOWTo Quick Exit the premises Using the # + 9 KeysQuick Exit Disarming And Silencing Alarms Using the 1 OFF KeyTo disarm the system and silence burglary or fire alarms Disarmed Ready to ARMDisarming Using The KeyswitchArming Chime Mode Using KeyChime Mode on Chime Mode OFFViewing Alarm Company Messages MESSAGE. Press For 5 SecsUsing Panic Keys Panic KeysEnter Speed KEY # Speed Key MacrosDefining Enter User Code Speed Key Macros cont’dExecuting Access Door Control Using #70 Relay Menu Mode Enter Device noUsing Schedules Delaying the Closing TimeClosing DELAY? KEY 0-2 Hours Temporary Open/Close SchedulesTo program temporary schedules Using Schedules cont’dProgramming Temporary Schedules Days ? Mtwtfss HIT 0-7 X Porch Lite Enter OUTPUT# Programming Device TimersTo enter the device timer menu mode Programming Device Timers cont’d DAYS? Mtwtfss HIT 0-7 X Permanent ?Randomize Output Device Times Using #77 Instant Activation Mode Action Code Action SpecifierUsing #77 Instant Activation Mode cont’d Bypass CommandsTo enter the Instant Activation Mode Action ? Are YOU Sure ?Quit Menu MODE? Zone List ?Event Log Procedures Enter Code + # + 6 + Select the display modeSelect the partition To Exit the Event Log Press at any timeTIME/DATE Event Logging ProceduresSetting the Time and Date Using Test Key Testing Your SystemFire Alarm System Case Of Fire AlarmSilencing a Fire Alarm Fire Display LockTrouble Conditions Typical Trouble DisplaysPower Failure Trouble Conditions cont’dRecommendations For Proper Protection Recommendations For Smoke And Heat DetectorsAddition, we recommend the following Recommendations For Proper Protection cont’dRecommendations For Proper Intrusion Protection Emergency Evacuation Taking Care of Your System Replacing Batteries in Wireless SensorsMaintaining Your System Routine Care Silencing Low Battery Warning Tones at the KeypadMaintaining Your System cont’d Function Procedure Comments Quick Guide To System FunctionsQuick Guide To System Functions cont’d AM/PMSummary Of Audible Notification Alpha Display KeypadsFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Index Advanced User InterfaceNfpa Night ¬.9l
Related manuals
Manual 80 pages 59.71 Kb

VISTA-128BP, VISTA-250BP specifications

The Honeywell VISTA-250BP and VISTA-128BP are advanced security control panels designed to provide robust protection for residential and commercial properties. These systems are part of Honeywell's VISTA series, known for their reliability and scalability, making them ideal for various applications.

One of the main features of the VISTA-250BP is its ability to support larger installations, accommodating up to 250 zones of security. This makes it an excellent choice for expansive properties or businesses that require comprehensive coverage. The VISTA-128BP is suited for smaller installations, providing support for up to 128 zones. Both panels offer flexibility in security device integration, allowing users to customize their security solutions according to their needs.

In terms of communication technologies, both panels are equipped with Honeywell's advanced encryption capabilities, ensuring that data transmission remains secure and protected from unauthorized access. They support a range of communication options, including Honeywell Total Connect, which allows users to monitor and control their security systems remotely via smartphones, tablets, or web browsers. This feature enhances convenience and responsiveness, especially for users who are frequently on the move.

Additionally, the VISTA-250BP and VISTA-128BP offer support for both wired and wireless security devices. This dual compatibility facilitates easier installations and makes it simpler for users to expand their security measures as their needs evolve. Users can seamlessly integrate devices such as door contacts, motion detectors, smoke detectors, and cameras, creating a comprehensive security blanket for their property.

Another notable characteristic of these panels is their user-friendly interface. The systems come equipped with a clear LCD display that provides real-time information and status updates, making it easy for users to navigate through various functions. Furthermore, the panels support multiple user codes, allowing different users to access the system with personalized access levels, enhancing overall security management.

Overall, the Honeywell VISTA-250BP and VISTA-128BP offer state-of-the-art security features, advanced communication technologies, and exceptional flexibility, making them ideal choices for both residential and commercial applications. Their scalability, user-friendly interfaces, and robust encryption capabilities ensure they meet the evolving needs of modern security demands.