Honeywell VISTA-128BP, VISTA-250BP manual System Overview, General

Page 5

System Overview

General

Congratulations on your ownership of an ADEMCO Partitioned Security System. You've made a wise decision in choosing it, for it represents the latest in security protection technology today. ADEMCO is the world's largest manufacturer of security systems and millions of premises are protected by ADEMCO systems.

This system offers you three forms of protection: burglary, fire and emergency. To realize the system's full potential, it is important that you feel comfortable in operating it. Your system consists of at least one Keypad which provides full control of system operation, various sensors which provide perimeter and interior burglary protection, plus a selected number of strategically placed smoke or combustion detectors designed to provide early warning in case of fire.

The system uses microcomputer technology to monitor all protection zones and system status and provides appropriate information for display on the Keypad(s) used with the system, and initiates appropriate alarms. Your system may also have been programmed to automatically transmit alarm or status messages over the phone lines to a central alarm monitoring station.

NOTE: If you have a Symphony (Advanced User Interface) and/or TeleSmart connected to your system, refer to the Symphony and TeleSmart User Guides for operating instructions for those units.

NOTE: All references in this manual for number of zones, number of user codes, number of access cards, and the event log capacity, use the VISTA-250BP’s features. The following table lists the differences between the VISTA-128BP and the VISTA-250BP control panels. Additionally, only the VISTA-128BP supports the capability to have a device duplicate keypad sounds at a remote location. All other features are identical for both panels.

 

Feature

VISTA-128BP

VISTA-250BP

 

 

 

 

 

 

 

Number of Zones

128

250

 

 

 

 

 

 

 

Number of User Codes

150

250

 

 

 

 

 

 

 

Number of Access Cards

250

500

 

 

 

 

 

 

 

Event Log Capacity

512

1000

 

 

 

 

 

 

 

VistaKey Modules

8

15

 

 

 

 

 

 

 

 

 

 

 

– 5 –

Image 5
Contents 67$%3 Page Table of Contents Programming Device Timers Using #70 Relay Menu ModeUsing #77 Instant Activation Setting the Time and DateGeneral System OverviewPartitioned System System Overview cont’dPanel Linking ZonesBurglary Protection AlarmsMemory of Alarm Device Timers Using SchedulesTo Access Another Partition Goto Command Speed Key MacrosPhone Access & Voice Response Capability Self-Help FeatureMaster Keypad Operation To view the abbreviated instructionsAlpha Keypad About The KeypadsFunction Keys LCD Display Functions Of The KeypadRemoves Individual Functions Of The Keypad cont’dFunctions Of The Keypad cont’d General Information Entry/Exit DelaysQuick Arming Security Codes & Authority LevelsDuress Code To view your authority level and system capabilities Security Codes & Authority Levels cont’dAuthority Levels General Rules on Authority Levels and Changes To Exit User Edit ModeCode To Add a UserMULTI-ACCESS ? 0 = no , 1 = YES To Change a Users Code To Delete a User To Access Another Partition Accessing Other PartitionsGlobal Arming To Goto another partitionStatus Accessing Other Partitions cont’dSystem Fault 002 Loading Dock Window Whse Disarmed HIT for FaultsCommon Lobby Operation Codes with Global Arming How User Codes Affect the Common LobbyCodes with Non-Global Arming Other Methods of Arming/DisarmingSingle-Partition Single-Panel Mode Accessing Other PanelsMulti-Partition Multi-Panel Mode Accessing Other Panels cont’dMulti-Panel View Mode Priority Description Display To show faulted zones Using Ready KeyFault 005 Front Upstairs Bedroom Disarmed Ready to ARM Typical fault displayDisplaying All Zone Descriptors Bypassing Protection Zones Using Bypass KeyTo bypass zones, the system must be disarmed first Bypass 007 Front Upstairs BedroomBypassing Protection Zones cont’d To use the Quick Bypass featureQuick Bypass Displaying Bypassed ZonesGroup Bypass To use the Group Bypass featureArmed ***STAY Zone Bypassed Using the 3 Stay keyArming Perimeter Only Auto-STAY Arming With Entry Delay on cont’dArmed *INSTANT1 Zone Bypassed Using the 7 Instant KeyArmed **AWAY YOU MAY Exit NOW Using Away KeyArming All Protection Armed *MAXIMUM* YOU MAY Exit NOW Using the 4 Maximum KeyTo Quick Exit the premises Using the # + 9 KeysQuick Exit Using the 1 OFF Key Disarming And Silencing AlarmsTo disarm the system and silence burglary or fire alarms Disarmed Ready to ARMDisarming Using The KeyswitchArming Using Key Chime ModeChime Mode on Chime Mode OFFMESSAGE. Press For 5 Secs Viewing Alarm Company MessagesPanic Keys Using Panic KeysEnter Speed KEY # Speed Key MacrosDefining Enter User Code Speed Key Macros cont’dExecuting Access Door Control Enter Device no Using #70 Relay Menu ModeDelaying the Closing Time Using SchedulesClosing DELAY? KEY 0-2 Hours Temporary Open/Close SchedulesTo program temporary schedules Using Schedules cont’dProgramming Temporary Schedules Days ? Mtwtfss HIT 0-7 X Porch Lite Enter OUTPUT# Programming Device TimersTo enter the device timer menu mode DAYS? Mtwtfss HIT 0-7 X Permanent ? Programming Device Timers cont’dRandomize Output Device Times Action Code Action Specifier Using #77 Instant Activation ModeBypass Commands Using #77 Instant Activation Mode cont’dAction ? Are YOU Sure ? To enter the Instant Activation ModeQuit Menu MODE? Zone List ?Enter Code + # + 6 + Select the display mode Event Log ProceduresSelect the partition To Exit the Event Log Press at any timeTIME/DATE Event Logging ProceduresSetting the Time and Date Testing Your System Using Test KeyCase Of Fire Alarm Fire Alarm SystemSilencing a Fire Alarm Fire Display LockTypical Trouble Displays Trouble ConditionsTrouble Conditions cont’d Power FailureRecommendations For Smoke And Heat Detectors Recommendations For Proper ProtectionAddition, we recommend the following Recommendations For Proper Protection cont’dRecommendations For Proper Intrusion Protection Emergency Evacuation Taking Care of Your System Replacing Batteries in Wireless SensorsMaintaining Your System Routine Care Silencing Low Battery Warning Tones at the KeypadMaintaining Your System cont’d Quick Guide To System Functions Function Procedure CommentsAM/PM Quick Guide To System Functions cont’dAlpha Display Keypads Summary Of Audible NotificationFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Advanced User Interface IndexNfpa Night ¬.9l
Related manuals
Manual 80 pages 59.71 Kb

VISTA-128BP, VISTA-250BP specifications

The Honeywell VISTA-250BP and VISTA-128BP are advanced security control panels designed to provide robust protection for residential and commercial properties. These systems are part of Honeywell's VISTA series, known for their reliability and scalability, making them ideal for various applications.

One of the main features of the VISTA-250BP is its ability to support larger installations, accommodating up to 250 zones of security. This makes it an excellent choice for expansive properties or businesses that require comprehensive coverage. The VISTA-128BP is suited for smaller installations, providing support for up to 128 zones. Both panels offer flexibility in security device integration, allowing users to customize their security solutions according to their needs.

In terms of communication technologies, both panels are equipped with Honeywell's advanced encryption capabilities, ensuring that data transmission remains secure and protected from unauthorized access. They support a range of communication options, including Honeywell Total Connect, which allows users to monitor and control their security systems remotely via smartphones, tablets, or web browsers. This feature enhances convenience and responsiveness, especially for users who are frequently on the move.

Additionally, the VISTA-250BP and VISTA-128BP offer support for both wired and wireless security devices. This dual compatibility facilitates easier installations and makes it simpler for users to expand their security measures as their needs evolve. Users can seamlessly integrate devices such as door contacts, motion detectors, smoke detectors, and cameras, creating a comprehensive security blanket for their property.

Another notable characteristic of these panels is their user-friendly interface. The systems come equipped with a clear LCD display that provides real-time information and status updates, making it easy for users to navigate through various functions. Furthermore, the panels support multiple user codes, allowing different users to access the system with personalized access levels, enhancing overall security management.

Overall, the Honeywell VISTA-250BP and VISTA-128BP offer state-of-the-art security features, advanced communication technologies, and exceptional flexibility, making them ideal choices for both residential and commercial applications. Their scalability, user-friendly interfaces, and robust encryption capabilities ensure they meet the evolving needs of modern security demands.