Honeywell Accessing Event Logs and Time Management for VISTA Home Security Systems

Page 60

Event Log Procedures

General Information

The system has the ability to record various events in a history log wherein each event is recorded in one of five categories (listed below), with the time and date of its occurrence. The Event Log holds up to 1000 events, with the oldest event being replaced by the logging of any new event after the log is full. Using an alpha keypad, the Event Log can be viewed one category at a time, or can display all events, regardless of category (ALL EVENT LOG). The system also allows selection of displaying the COMPLETE log, or only those events occurring since the last installer service (RECENT). In addition, events in the other partitions can be viewed by users authorized to access those partitions. Note that events are displayed in chronological order, from most recent to oldest.

To Display The Event Log

1.Enter CODE + [#] + [6] + [0]

2.Select the display mode.

RECENT: Displays only those events occurring since last Event Log Clear command was executed.

COMPLETE: Displays complete event log (up to 1000 events).

Press the desired key, 0 or 1.

ENTER 0 = RECENT 1 = COMPLETE

3.Select the partition, 0-8.

Enter the partition number for the partition whose events are to be displayed.

Entering 0 (NO) will display all partitions' events.

SCAN LOG BY PART 0=NO 1-8=PART #

4.Use the [3] & [1] keys (for next and previous categories respectively) to display the categories of events.

Press [8] to select a category and display the first event. Press [8] again for each subsequent event.

Shows burglary alarm occurred in zone 3 (C03) of partition 1 (P1), at 12:02AM on January 1.

P1 01/01 12:02AM

Typical

BURGLARY C003

Event Log

 

Display

After the last event has been displayed, the END OF EVENT LOG message appears for a few seconds, then the system automatically displays the RECENT/COMPLETE mode select screen again (see step 2).

5.To EXIT the Event Log: Press ["] at any time.

ALARM EVENT LOG

Typical

TYPE CCC UUU

Category

 

Select Screen

– 60 –

Image 60
Contents 67$%3 Page Table of Contents Using #70 Relay Menu Mode Programming Device TimersUsing #77 Instant Activation Setting the Time and DateSystem Overview GeneralSystem Overview cont’d Partitioned SystemPanel Linking ZonesAlarms Memory of AlarmBurglary Protection Using Schedules Device TimersTo Access Another Partition Goto Command Speed Key MacrosSelf-Help Feature Phone Access & Voice Response CapabilityMaster Keypad Operation To view the abbreviated instructionsAbout The Keypads Alpha KeypadFunctions Of The Keypad Function Keys LCD DisplayFunctions Of The Keypad cont’d Removes IndividualFunctions Of The Keypad cont’d Entry/Exit Delays General InformationSecurity Codes & Authority Levels Duress CodeQuick Arming Security Codes & Authority Levels cont’d Authority LevelsTo view your authority level and system capabilities To Exit User Edit Mode General Rules on Authority Levels and ChangesTo Add a User CodeMULTI-ACCESS ? 0 = no , 1 = YES To Change a Users Code To Delete a User Accessing Other Partitions To Access Another PartitionGlobal Arming To Goto another partitionAccessing Other Partitions cont’d SystemStatus Whse Disarmed HIT for Faults Fault 002 Loading Dock WindowCommon Lobby Operation How User Codes Affect the Common Lobby Codes with Global ArmingCodes with Non-Global Arming Other Methods of Arming/DisarmingAccessing Other Panels Single-Partition Single-Panel ModeAccessing Other Panels cont’d Multi-Partition Multi-Panel ModeMulti-Panel View Mode Priority Description Display Using Ready Key To show faulted zonesFault 005 Front Upstairs Bedroom Disarmed Ready to ARM Typical fault displayDisplaying All Zone Descriptors Using Bypass Key Bypassing Protection ZonesTo bypass zones, the system must be disarmed first Bypass 007 Front Upstairs BedroomTo use the Quick Bypass feature Bypassing Protection Zones cont’dQuick Bypass Displaying Bypassed ZonesTo use the Group Bypass feature Group BypassUsing the 3 Stay key Arming Perimeter OnlyArmed ***STAY Zone Bypassed With Entry Delay on cont’d Auto-STAY ArmingUsing the 7 Instant Key Armed *INSTANT1 Zone BypassedUsing Away Key Arming All ProtectionArmed **AWAY YOU MAY Exit NOW Using the 4 Maximum Key Armed *MAXIMUM* YOU MAY Exit NOWUsing the # + 9 Keys Quick ExitTo Quick Exit the premises Disarming And Silencing Alarms Using the 1 OFF KeyTo disarm the system and silence burglary or fire alarms Disarmed Ready to ARMUsing The Keyswitch ArmingDisarming Chime Mode Using KeyChime Mode on Chime Mode OFFViewing Alarm Company Messages MESSAGE. Press For 5 SecsUsing Panic Keys Panic KeysSpeed Key Macros DefiningEnter Speed KEY # Speed Key Macros cont’d ExecutingEnter User Code Access Door Control Using #70 Relay Menu Mode Enter Device noUsing Schedules Delaying the Closing TimeClosing DELAY? KEY 0-2 Hours Temporary Open/Close SchedulesUsing Schedules cont’d Programming Temporary SchedulesTo program temporary schedules Days ? Mtwtfss HIT 0-7 X Programming Device Timers To enter the device timer menu modePorch Lite Enter OUTPUT# Programming Device Timers cont’d DAYS? Mtwtfss HIT 0-7 X Permanent ?Randomize Output Device Times Using #77 Instant Activation Mode Action Code Action SpecifierUsing #77 Instant Activation Mode cont’d Bypass CommandsTo enter the Instant Activation Mode Action ? Are YOU Sure ?Quit Menu MODE? Zone List ?Event Log Procedures Enter Code + # + 6 + Select the display modeSelect the partition To Exit the Event Log Press at any timeEvent Logging Procedures Setting the Time and DateTIME/DATE Using Test Key Testing Your SystemFire Alarm System Case Of Fire AlarmSilencing a Fire Alarm Fire Display LockTrouble Conditions Typical Trouble DisplaysPower Failure Trouble Conditions cont’dRecommendations For Proper Protection Recommendations For Smoke And Heat DetectorsRecommendations For Proper Protection cont’d Recommendations For Proper Intrusion ProtectionAddition, we recommend the following Emergency Evacuation Replacing Batteries in Wireless Sensors Maintaining Your SystemTaking Care of Your System Silencing Low Battery Warning Tones at the Keypad Maintaining Your System cont’dRoutine Care Function Procedure Comments Quick Guide To System FunctionsQuick Guide To System Functions cont’d AM/PMSummary Of Audible Notification Alpha Display KeypadsFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Index Advanced User InterfaceNfpa Night ¬.9l
Related manuals
Manual 80 pages 59.71 Kb

VISTA-128BP, VISTA-250BP specifications

The Honeywell VISTA-250BP and VISTA-128BP are advanced security control panels designed to provide robust protection for residential and commercial properties. These systems are part of Honeywell's VISTA series, known for their reliability and scalability, making them ideal for various applications.

One of the main features of the VISTA-250BP is its ability to support larger installations, accommodating up to 250 zones of security. This makes it an excellent choice for expansive properties or businesses that require comprehensive coverage. The VISTA-128BP is suited for smaller installations, providing support for up to 128 zones. Both panels offer flexibility in security device integration, allowing users to customize their security solutions according to their needs.

In terms of communication technologies, both panels are equipped with Honeywell's advanced encryption capabilities, ensuring that data transmission remains secure and protected from unauthorized access. They support a range of communication options, including Honeywell Total Connect, which allows users to monitor and control their security systems remotely via smartphones, tablets, or web browsers. This feature enhances convenience and responsiveness, especially for users who are frequently on the move.

Additionally, the VISTA-250BP and VISTA-128BP offer support for both wired and wireless security devices. This dual compatibility facilitates easier installations and makes it simpler for users to expand their security measures as their needs evolve. Users can seamlessly integrate devices such as door contacts, motion detectors, smoke detectors, and cameras, creating a comprehensive security blanket for their property.

Another notable characteristic of these panels is their user-friendly interface. The systems come equipped with a clear LCD display that provides real-time information and status updates, making it easy for users to navigate through various functions. Furthermore, the panels support multiple user codes, allowing different users to access the system with personalized access levels, enhancing overall security management.

Overall, the Honeywell VISTA-250BP and VISTA-128BP offer state-of-the-art security features, advanced communication technologies, and exceptional flexibility, making them ideal choices for both residential and commercial applications. Their scalability, user-friendly interfaces, and robust encryption capabilities ensure they meet the evolving needs of modern security demands.