F90A,B
PERFORMANCE
SWITCH
BLACK |
| |
|
| |
BLACK | 3 | |
| ||
| WHITE | |
WASH | RED | |
(YELLOW) |
|
|
| RED | |
ON | WHITE | |
(YELLOW) |
|
POWER
SUPPLY
P3
P4
J2
2
P21 4 P22
3
1
P2
P1
BLACK COLLECTOR |
|
| |
| RED IONIZER |
| TEST |
| RED | BUTTON | |
|
|
| |
|
| BLACK |
|
| CHECK |
|
|
RED | (RED) |
|
|
|
|
| |
WHITE |
|
|
|
CONTACT BOARD
PUSH BUTTONS | WIRING TERMINALS |
HI | ON |
MED | HI |
LO | MED |
OFF | LO |
| L1 | BLACK | ORANGE |
| |||
(HOT) |
| ||
| 2 | ||
1 |
| WHITE |
|
| L2 |
| |
|
|
| |
| GROUND | GREEN |
|
|
|
|
BROWN
VIOLET
BLUE
RED
FAN
MOTOR
WHITE
1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
2 INTERLOCK SAFETY SWITCH.
3 REPLACE THE BLACK LEADS.
M6152
Fig. 22. F90A 120 Vac model schematic diagram.
P3
PERFORMANCE
SWITCH
P4
| BLACK |
|
ON | BLACK | J5 |
WHITE |
| |
(YELLOW) |
| |
|
| |
| RED |
|
WASH | WHITE |
|
|
| |
(YELLOW) | RED |
|
CHECK | WHITE |
|
RED |
| |
(RED) |
| |
|
|
PUSH BUTTONS WIRING TERMINALS
HI | ON |
MED | HI |
LO | MED |
OFF | LO |
| L1 | BLACK | ORANGE |
| |||
(HOT) |
| ||
| 3 | ||
1 |
|
|
|
| L2 |
|
|
| GROUND |
|
|
POWER
SUPPLY
P2
P1
BROWN
VIOLET
BLUE
RED
FAN
MOTOR
WHITE
BLACK COLLECTOR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||
RED IONIZER |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TEST | |||||||||||||||||||||||||||||||
|
|
|
|
| RED |
| BUTTON | |||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| CONTACT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BOARD | ||
|
|
|
|
|
|
|
|
|
|
|
| BLACK |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||
2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
2 LEFT CELL AND CONTACT BOARD ON
3 INTERLOCK SAFETY SWITCH.
M11576
Fig. 23. F90A 120 Vac model schematic diagram.
19 |