OPERATING YOUR HUMIDIFIER

HE225A,B AND HE265A,B BY-PASS FLOW-THROUGH HUMIDIFIERS

OPERATING YOUR HUMIDIFIER

HE225A,HE265A

Your Enviracaire Elite™ HE225A and HE265A Humidifiers from Honeywell are controlled by the H8908B Convertible Humidity Control. The convertible humidity control is installed either on an interior wall in the living area, or on the return air duct. Choose the humidity control setting using the combination relative humidity/outdoor temperature setting scale on your humidity control dial. Match the dial setting to the outdoor temperature for optimizing the humidity level while reducing moisture conden- sation on your windows. The table below can also be used to adjust humidity control to the recommended setting.

 

 

OUTDOOR

HUMIDITY

 

 

TEMPERATURE

SETTING

 

 

-20 °F

-30 °C

15%

 

 

-10 °F

-25 °C

20%

 

 

0 °F

-20 °C

25%

 

 

+10 °F

-10 °C

30%

Humidity

Control

+20 °F

-5 °C

35%

Over 0 °C

40%

 

Over 20 °F

Régulateur d'humidité

 

 

 

M14694

At Outside

Recommended

At Outside

Recommended

Temperature

Control Setting

Temperature

Control Setting

-20°F (-29°C)

15

+10°F (-12°C)

30

 

 

 

 

-10°F (-23°C)

20

+20°F (-7°C)

35

 

 

 

 

0°F (-18°C)

25

Above 20°F (-7°C)

40

NOTE: As outside temperature drops, the recommended humidity control setting is lowered to adjust for effects of dewpoint. These settings should reduce accu- mulation of moisture and ice on your windows and other areas of your home.

Some indoor activities such as cooking, showering and clothes drying can cause excessive levels of humidity and start the accumulation of moisture on your windows.

NOTE: If this condition persists for more than a few hours, set the humidity control to the lowest setting to turn off the humidifier. If the condition does not improve, ventilate your home to remove the moisture.

HE225B,HE265B

Your Enviracaire Elite™ HE225B and HE265B Humidifiers are ontrolled by the Honeywell H1008 Automatic Humidity Control with HumidCalc+™. The automatic humidity control is mounted in the return air duct where it can be exposed to the air stream of the return air.

H1008AM12817

3

69-1423EF-3

Image 3
Contents All Rights Reserved OWNER’S GUIDEU.S. Registered Trademark Copyright 2003 Honeywell International IncPage HE225B,HE265B Control SettingOPERATING YOUR HUMIDIFIER HE225A,HE265AHumidity Level Recommended SettingHOW YOUR HUMIDIFIER WORKS MAINTAINING YOUR HUMIDIFIERSerious Personal Injury Hazard Be sure humidifier power is offEvery 1 to 3 Months Depending on Water Quality End of Humidification SeasonVacation TROUBLESHOOTING YOUR HUMIDIFIERProblem CHECKING YOUR HUMIDIFIER OPERATIONHow it works... THE Describing PerfectionWARRANTY Page Page 69-1423EF-3 MANUEL DU PROPRIÉTAIREEPA.National Air Quality 1999 Status & Trends RÉGLAGE DE L’HUMIDIFICATEUR RéglageRéglage Niveau d’humidité Réglage recommandéCOMMENT FONCTIONNE L’HUMIDIFICATEUR INSTRUCTIONS D’ENTRETIENAVERTISSEMENT Risque de choc électriqueFin de la saison d’humidification VacancesS’assurer que l’appareil est à l’arrêt Page Ce qu’il faut faire DÉPANNAGEProblème Ce qu’il faut vérifierRÉGULATEURS Perfect Climate POUR PLUS DE CONFORT ET DE COMMODITÉPour décrire la perfection Solutions de régulation et dautomatisation GARANTIE