Honeywell HE265A, HE225A, B How Your Humidifier Works, Maintaining Your Humidifier, Humidity Level

Page 4
Humidity Level

HE225A,B AND HE265A,B BY-PASS FLOW-THROUGH HUMIDIFIERS

The HumidCalc+™ software inside your automatic humidity control is designed to measure or infer outdoor temperature and automatically adjust the humidity based on the frost factor setting that the homeowner sets to allow for variances in furnace size, window type and insulation.

The Automatic Humidity Control with HumidiCalc+™ requires an initial adjustment period. For maximum humidification, set the H1008 to 10 and run the fan continuously. Check for condensation on windows after a cold night. If there is no condensation, leave the setting at 10. If there is condensation, lower the frost factor dial one setting. Continue to check for condensation on cold mornings until the correct humidity setting is reached for your home. Allow two days between adjustments to determine if further adjustment is necessary. Once you have tuned in the proper setting, you should never have to adjust it again. HumidiCalc+™ takes over and makes any future adjustments caused by varying outdoor temperatures, thus reducing moisture build-up on windows while maintaining the optimal humidity level.

Humidity Level

Recommended Setting

Insufficient humidity

Increase the frost factor dial by one setting.

Condensation on windows

Decrease the frost factor dial by one setting.

HOW YOUR HUMIDIFIER WORKS

Your Enviracaire Elite™ humidifier uses the principle that vapor (evaporated water) is created when warm air blows over a water soaked area. As the vapor circulates, the relative humidity rises.

Your humidity control monitors the relative humidity and activates the humidifier accordingly. The humidifier has a water supply that dispenses water evenly over the AgION™ antimicrobial humidifier pad. The warm dry air, from the furnace, passes over the humidifier pad and picks up the moist air to circulate it throughout your home.

Humidified air feels warmer and more comfortable so you may be able to lower your thermostat heating setpoint, which saves money on your heating fuel bills. The end result is that your humidifier gives you a cleaner, more comfortable environment that is also energy efficient.

MAINTAINING YOUR HUMIDIFIER

.A regular maintenance program prolongs the life of your humidifier and provides a more comfortable home. Frequency of cleaning depends on the condition of your water. You can use either hard or soft water in your humidifier, but hard water mineral deposits are more difficult to clean than soft water deposits. For optimum performance, Honeywell recommends replacing the AgION™ antimicrobial pad once a year. Use the following procedure to clean your Honeywell humidifier.

69-1423EF-3

4

Image 4
Contents OWNER’S GUIDE U.S. Registered TrademarkCopyright 2003 Honeywell International Inc All Rights ReservedPage Control Setting OPERATING YOUR HUMIDIFIERHE225A,HE265A HE225B,HE265BRecommended Setting HOW YOUR HUMIDIFIER WORKSMAINTAINING YOUR HUMIDIFIER Humidity LevelBe sure humidifier power is off Every 1 to 3 Months Depending on Water QualityEnd of Humidification Season Serious Personal Injury HazardTROUBLESHOOTING YOUR HUMIDIFIER ProblemCHECKING YOUR HUMIDIFIER OPERATION VacationDescribing Perfection How it works... THEWARRANTY Page Page MANUEL DU PROPRIÉTAIRE 69-1423EF-3EPA.National Air Quality 1999 Status & Trends Réglage RÉGLAGE DE L’HUMIDIFICATEURRéglage Réglage recommandé COMMENT FONCTIONNE L’HUMIDIFICATEURINSTRUCTIONS D’ENTRETIEN Niveau d’humiditéRisque de choc électrique AVERTISSEMENTVacances Fin de la saison d’humidificationS’assurer que l’appareil est à l’arrêt Page DÉPANNAGE ProblèmeCe qu’il faut vérifier Ce qu’il faut faireCONFORT ET DE COMMODITÉ RÉGULATEURS Perfect Climate POUR PLUS DEPour décrire la perfection GARANTIE Solutions de régulation et dautomatisation