Honeywell PRO22ENC2, PRO22ENC1 installation manual Second PC Installation, Enterprise Manager Setup

Page 13

14

Installation Guide

PRO-2200 Enclosure PRO22ENC1 & PRO22ENC2

7.Use the Query Analyzer to connect to the WIN-PAK PRO database using the provided script for attachment.

8.Open up the ODBC application in the Control Panel and create a link to the WIN-PAK PRO SQL database. The name used for a description should match the WIN-PAK PRO System Manger DSN Tab name. Default is WIN-PAK Database. See the WINPAK PRO installation manual for complete procedure.

9.The database server can now be started. Launch the User Interface and connect using ADMIN as the name without a password.10. The database should now be programmed to accommodate the PRO22IC panel

and accompanying I/O boards. Refer to the WINPAK PRO Installation Manual for additional detail. The programming should continue until the system is fully functional and communications have been established. Below are the programming requirements for setting up the PRO22IC panel.

A.Direct to Port selection required when adding a new PRO22IC.

B.A unique TCP/IP address is required for assignment to the panel and should match the IP address you programmed through the Cobox software.

C.Program all the ADV’s for the hardware so that you will be able to monitor the points and system alarms.

D.Once the program is configured, shut down the User Interface and restart all the services. Launch the User Interface and verify communications.

E.Program the Communications Server with Local Machine for the Node Name.

F.Program a Control Map and/or Floorplans with the hardware. Example: Panels, SIO boards, Inputs, Outputs, readers, Comm Server.

G.All Servers added to the Device Map use Local Machine for the Node Name.

NOTE: Use the SQL Enterprise Manger to backup the programmed database. Refer to the SQL Server Manual for instructions.

CAUTION: If the instructions describing the Data Transformation Services are not followed exactly your database could be overwriten.

Second PC Installation

Follow Instructions 1 through 4 and 6 through 8 listed on pages 12 and 13.

Enterprise Manager Setup

1.Open up Enterprise Manager from the secondary PC, the PC you will use for Redun- dancy.

2.Right-click and expand the SQL Server Group.

3.Right-click and expand the Computer Name Group.

4.Right-click on the WIN-PAK PRO Database and select All Tasks then Import Data.

5.Click Next. Verify that the Server is selected as MAIN. The database should be WIN-PAK PRO. (The source database)

Image 13
Contents Part Number PRO22ENC1 PRO22ENC2 PRO-2200 Enclosure Installation ManualTD1138 rev0801 Contents Fire Safety and Liability Notice Warnings and CautionsBUT NOT BOTH Page Disclaimer Unpacking ProcedureProduct Liability Mutual Indemnification Shipping Instructions Limited WarrantyTo ship equipment back to Engineered Systems Confidentiality Description PRO-2200EnclosurePower Supply DimensionsMaintenance Installation InstructionsInstallation Diagram Receiving Unit minimum configuration UL1076 SetupPC Minimum Requirements Peripheral Hardware RequirementsOther UL1075 Notes ProceduresA.Select Full Installation B.Select SQL for DatabaseEnterprise Manager Setup Second PC InstallationDTS Package Verification Pre-RedundancyVerificationInterim Steps Before Full Redundancy Verification Redundant Test Examples Power Supply DimensionsExample #1 Example #2Power Supply Enclosure Installation DiagramDimensions Installation GuideInstallation Instructions InstallationCable Specifications ESG Cable Part Numbers PRO-2200Enclosure PRO22ENC1 & PRO22ENC2 Installation GuidePRO-2200Enclosure PRO22ENC1 & PRO22ENC2 Installation GuidePRO-2200Enclosure PRO22ENC1 & PRO22ENC2 Installation Guide2700 Blankenbaker Pkwy, Suite Louisville, KY Honeywell Security & Data Collection