Honeywell L5100 manual Index Description

Page 11

SYSTEM OVERVIEW

About the Touch screen Control

Note: The system functions described below are for reference only and require additional key entries to activate.

Index

Item

Description

 

 

 

1

Display

Color Liquid Crystal Display (LCD) Touch screen. Displays system status icons,

 

Window

time, system status information, user menus and the virtual keypad.

2

 

ON = System is ready to be armed

 

Ready LED

OFF = System is armed

 

Blinking = System is disarmed, and not ready to be armed (a fault exists)

 

Indicator

 

Blinking alternately with Ready LED = Speaker phone mode is active

 

(Green)

 

 

3

Home key

Used to exit from a screen or return to the home screen.

4

Speaker

Source of audible internal warning and confirmation sounds, status announce-

 

 

ments, as well as alarms (see "Summary of Audible Notifications").

 

 

 

5

Off (Disarm) key

Initiates the disarm process and causes a keypad to be displayed on the touch screen. Disarms the burglary portion of the system, silences alarms and audible trouble indicators, and clears alarm trouble display after the problem has been corrected.

6

Away key

Completely arms both perimeter and interior burglary protection for backup protection by sensing an intruder's movements through protected interior areas as well as guarding protected doors, windows, etc. Entrance can be made through an entry delay zone without causing an alarm if the system is disarmed before the entry delay time expires.

7

Panic key

When depressed for 4 seconds, the virtual panic icons are displayed on the touch screen.

8

Microphone

Used to record personal messages via the Message Center, and for two-way voice and speaker phone operation.

9

Armed LED Indicator (Red)

ON = System is armed (STAY or AWAY) OFF = System is disarmed

Blinking = System armed, and an alarm or fault has occurred. Blinking alternately with Ready LED = Speaker phone mode is active

– 11 –

Image 11
Contents Lynx Touch Security System Page Table of Contents System Functions General Information FeaturesBurglary Protection ZonesFire Protection Carbon MonoxideSecurity Codes AlarmsTwo-Way Voice Feature General OperationLynx Touch SIA False Alarm Prevention Features Security Functions Quick View of System FunctionsGeneral About the Touch screen ControlIndex Description System is Disarmed and ready to arm About the Display and IndicatorsDisplay Definitions Displayed along with the the text Ready To Arm whenSystem Overview Lynx Touch Dashboard Screen Typical Navigating MenusLCD Display Dashboard ScreenLynx Touch Security Home Screen Navigation KeysFunction Keys Unrestricted Menu Menu ScreensMenus Master Menu System Can Be Armed System StatusArming the System Arming in Stay ModeAuto Stay Feature Arming In Away Mode Armed Away Quick Exit Arming the System with no delay InstantExit Alarms Entry/Exit DelaysExit Delay Entry Delay Disarming the System Disarming the System and Silencing AlarmsDisarming the System During Entry Delay When an Alarm OccursBypassing Zones Bypassing Protection ZonesBypassing Individual Zones Displaying/Clearing Bypassed Zones FaultedKey Function Types of Panic AlarmsPanic Keys Panic KeysActivating a Panic Alarm Turning Chime Mode On or Off Chime ModeChime Mode Turning Voice Mode On or Off Voice ModeVoice Mode Adding a User User AccessUser User3 Editing/Deleting a User 123!@#Q W Viewing System Events View EventsAll Recording a Message Entering Message ModeMessage Recording and Playback Deleting Messages Playing MessagesChange System Settings System SettingsClock/Calendar Setting the Date and TimeOn the keypad and select AM or PM Second Third Fourth Last Next to Last 3rd from Last First Programming Rules AutomationRules Disabled None Permanent On On for 2 sec Pulsing Send Run Scene Start of Entry Delay Chime Kissoff Bypass System Low Battery Editing or Deleting Rules Programming a Scheduled Function SchedulesNone Deleting a Scheduled Function Editing a Scheduled FunctionProgramming a Scene ScenesLocks Editing/Deleting a Scene Running a Scene Programming a Reminder RemindersPlay Deleting a Reminder Editing a ReminderView/Join Available WiFi Networks WiFi ConfigurationManually Configure Access Point Viewing or Deleting Enrolled Keypads Enrolling/Syncing Auxiliary KeypadsUsing the Speaker Phone Feature Speaker Phone FeatureAnswering a Call Placing a CallRemote Phone Control Commands Remote Phone Control FeatureUsing Remote Phone Control Feature Remote Services Activating the Slide Show Slide ShowSlide Internal General Information FIRE/CO Alarm System If InstalledCase of Carbon Monoxide Alarm Silencing a Fire/Carbon Monoxide AlarmFIRE/CO Alarm System Emergency Evacuation Test Modes Testing the System to be conducted weeklyEntering Test Mode Testing or Rebooting the SystemWalk Test Exiting Test Mode Routine Care Cleaning the Touch screenMaintaining your system Changing the Lynx Touch Series System Battery Low Battery Conditions in Wireless SensorsAdditional Announcements Summary of Audible & Visual NotificationsDisplay Definition System DisplaysLED Meanings Zone Status IconsIndustry Canada IC Regulatory Agency StatementsTELEPHONE/MODEM Interface Event of Telephone Operational Problems Owners Insurance Premium Credit Request Owners Insurance Premium Credit Request Servicing Information Limitations of this Alarm System Page Page Page Page Index Touchscreen Control TWO Year Limited Warranty Corporate Center Drive, Suite Box 9040, Melville, NY