SECURING THE PREMISES

Arming the System

Arming the System with no delay (Instant)

Use “Instant” with Stay mode when you are staying home and do not expect anyone to use the entrance door. Use “Instant” with Away mode when the premises will be vacant for extended periods of time such as vacations, etc. When armed with “Instant”, the system will sound an alarm if a protected door or window is opened, including the entrance door. You may leave through the entrance door during the exit delay period without causing an alarm, but an alarm will sound as soon as someone reenters.

When armed “Instant” with Stay mode, the control beeps three times and displays the “Armed Stay Instant” message. In addition, the red Armed indicator lights and the system announces “Armed Stay Instant –exit now”.

When armed “Instant” with Away mode, the control beeps two times and displays the “Armed Away Instant” message. If Exit Warning is enabled the system beeps continuously for the duration of the exit delay. In addition, the red Armed indicator lights and the system announces “Armed Away Instant –exit now”.

To Arm the System with No Delay (Instant)

Ready To Arm

 

 

 

72

 

 

Zones

Automation

Arm Away

Arm Stay

Message

Phone

Delay

10:18 AM June 8, 2010

More

1.Select the “Delay” tab on the home screen. The icon “toggles” and “Instant” is displayed.

2.Arm the system in the “Stay” or Away” mode normally.

Note: The entry delay time is eliminated when “Instant” is selected.

5000-100-006-V1

Quick Exit

If active, you can restart the exit delay at any time after arming has been armed in Stay or Away mode by selecting the “Quick Exit” icon. This avoids having the user disarm then re- arm the system after allowing someone to enter or exit. The system will re-arm once the exit delay expires.

Armed Stay

 

 

 

72

 

 

Zones

Automation

Disarm

Quick Exit

Message

Phone

 

10:18 AM June 8, 2010

More

1.Select the “Quick Exit” icon to restart the exit delay.

Note: Quick Exit is active in Away mode when: Auto Stay mode is enabled and no entry/exit zone has been faulted during the exit delay period.

5000-100-060-V1

– 23 –

Image 23
Contents Lynx Touch Security System Page Table of Contents System Functions General Information FeaturesBurglary Protection ZonesFire Protection Carbon MonoxideSecurity Codes AlarmsTwo-Way Voice Feature General OperationLynx Touch SIA False Alarm Prevention Features Security Functions Quick View of System FunctionsGeneral About the Touch screen ControlIndex Description System is Disarmed and ready to arm About the Display and IndicatorsDisplay Definitions Displayed along with the the text Ready To Arm whenSystem Overview Lynx Touch Dashboard Screen Typical Navigating MenusLCD Display Dashboard ScreenLynx Touch Security Home Screen Navigation KeysFunction Keys Unrestricted Menu Menu ScreensMenus Master Menu System Can Be Armed System StatusArming the System Arming in Stay ModeAuto Stay Feature Arming In Away Mode Armed Away Quick Exit Arming the System with no delay InstantExit Alarms Entry/Exit DelaysExit Delay Entry Delay Disarming the System Disarming the System and Silencing AlarmsDisarming the System During Entry Delay When an Alarm OccursBypassing Zones Bypassing Protection ZonesBypassing Individual Zones Displaying/Clearing Bypassed Zones FaultedKey Function Types of Panic AlarmsPanic Keys Panic KeysActivating a Panic Alarm Turning Chime Mode On or Off Chime ModeChime Mode Turning Voice Mode On or Off Voice ModeVoice Mode Adding a User User AccessUser User3 Editing/Deleting a User 123!@#Q W Viewing System Events View EventsAll Recording a Message Entering Message ModeMessage Recording and Playback Deleting Messages Playing MessagesChange System Settings System SettingsClock/Calendar Setting the Date and TimeOn the keypad and select AM or PM Second Third Fourth Last Next to Last 3rd from Last First Programming Rules AutomationRules Disabled None Permanent On On for 2 sec Pulsing Send Run Scene Start of Entry Delay Chime Kissoff Bypass System Low Battery Editing or Deleting Rules Programming a Scheduled Function SchedulesNone Deleting a Scheduled Function Editing a Scheduled FunctionProgramming a Scene ScenesLocks Editing/Deleting a Scene Running a Scene Programming a Reminder RemindersPlay Deleting a Reminder Editing a ReminderView/Join Available WiFi Networks WiFi ConfigurationManually Configure Access Point Viewing or Deleting Enrolled Keypads Enrolling/Syncing Auxiliary KeypadsUsing the Speaker Phone Feature Speaker Phone FeatureAnswering a Call Placing a CallRemote Phone Control Commands Remote Phone Control FeatureUsing Remote Phone Control Feature Remote Services Activating the Slide Show Slide ShowSlide Internal General Information FIRE/CO Alarm System If InstalledCase of Carbon Monoxide Alarm Silencing a Fire/Carbon Monoxide AlarmFIRE/CO Alarm System Emergency Evacuation Test Modes Testing the System to be conducted weeklyEntering Test Mode Testing or Rebooting the SystemWalk Test Exiting Test Mode Routine Care Cleaning the Touch screenMaintaining your system Changing the Lynx Touch Series System Battery Low Battery Conditions in Wireless SensorsAdditional Announcements Summary of Audible & Visual NotificationsDisplay Definition System DisplaysLED Meanings Zone Status IconsIndustry Canada IC Regulatory Agency StatementsTELEPHONE/MODEM Interface Event of Telephone Operational Problems Owners Insurance Premium Credit Request Owners Insurance Premium Credit Request Servicing Information Limitations of this Alarm System Page Page Page Page Index Touchscreen Control TWO Year Limited Warranty Corporate Center Drive, Suite Box 9040, Melville, NY