About the Display and Indicators

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ICON

TEXT

DEFINITION

 

 

 

 

 

 

 

 

 

Alarm 96

The Medical icon displayed when a medical alarm is activated.

 

 

 

 

 

 

 

 

 

Medical

“Alarm” is also displayed in a red band along the top of the

 

 

 

 

 

 

 

 

 

 

screen.

 

 

 

 

 

 

 

 

 

 

(If programmed for display by your installer)

 

 

 

 

 

 

 

 

 

 

Alarm 99

The alarm (bell) icon when a burglary alarm is activated.

 

 

 

 

 

 

 

 

 

Police

“Alarm” is also displayed in a red band along the top of the

 

 

 

 

 

 

 

 

 

 

screen. (If programmed for display by your installer) No

 

 

 

 

 

 

 

 

 

 

display if 24 Hour Silent Response Type has been

 

 

 

 

 

 

 

 

 

 

programmed.

 

 

 

 

 

 

 

 

 

 

CO Alarm

Displayed alternately with Carbon Monoxide when a CO alarm

 

 

 

 

 

 

 

 

 

 

is activated.

 

 

 

 

 

 

 

 

 

 

“CO Alarm” is also displayed in a red band along the top of the

 

 

 

 

 

 

 

 

 

 

screen.

 

 

 

 

 

 

 

 

 

 

Cover

A check system icon along with “Cover Tamper” is displayed

 

 

 

 

 

 

 

 

 

Tamper

when a cover tamper has been detected. “Ready To Arm –

 

 

 

 

 

 

 

 

 

 

System Trouble” is displayed in a yellow band along the top of

 

 

 

 

 

 

 

 

 

 

the screen.

 

 

 

 

 

 

 

 

 

 

Reporter

The system has identified a problem with the telephone dialer.

 

 

 

 

 

 

 

 

 

Failure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low

“Not Ready To Arm – System Trouble” is displayed in a yellow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery

band along the top of the screen. A low battery icon along with

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“Low Battery” is displayed when the system’s backup battery

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

power is low.

 

 

 

 

 

 

 

 

 

 

90 RF Jam

Appears when the system has detected an RF jamming

 

 

 

 

 

 

 

 

 

 

condition or excessive interference.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

94 Phone

Appears when the system has detected a loss of telephone

 

 

 

 

 

 

 

 

 

Line Cut

service.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC Loss

Displayed when the system has lost AC power. “Ready To Arm – System Trouble” is displayed in a yellow band along the top of the screen.

– 13 –

Image 13
Contents Lynx Touch Security System Page Table of Contents System Functions General Information FeaturesFire Protection ZonesCarbon Monoxide Burglary ProtectionTwo-Way Voice Feature AlarmsGeneral Operation Security CodesLynx Touch SIA False Alarm Prevention Features Security Functions Quick View of System FunctionsGeneral About the Touch screen ControlIndex Description Display Definitions About the Display and IndicatorsDisplayed along with the the text Ready To Arm when System is Disarmed and ready to armSystem Overview LCD Display Navigating MenusDashboard Screen Lynx Touch Dashboard Screen TypicalFunction Keys Navigation KeysLynx Touch Security Home Screen Menus Menu ScreensUnrestricted Menu Master Menu System Can Be Armed System StatusArming the System Arming in Stay ModeAuto Stay Feature Arming In Away Mode Armed Away Quick Exit Arming the System with no delay InstantExit Delay Entry/Exit DelaysExit Alarms Entry Delay Disarming the System Disarming the System and Silencing AlarmsDisarming the System During Entry Delay When an Alarm OccursBypassing Individual Zones Bypassing Protection ZonesBypassing Zones Displaying/Clearing Bypassed Zones FaultedPanic Keys Types of Panic AlarmsPanic Keys Key FunctionActivating a Panic Alarm Chime Mode Chime ModeTurning Chime Mode On or Off Voice Mode Voice ModeTurning Voice Mode On or Off Adding a User User AccessUser User3 Editing/Deleting a User 123!@#Q W Viewing System Events View EventsAll Message Recording and Playback Entering Message ModeRecording a Message Deleting Messages Playing MessagesChange System Settings System SettingsClock/Calendar Setting the Date and TimeOn the keypad and select AM or PM Second Third Fourth Last Next to Last 3rd from Last First Rules AutomationProgramming Rules Disabled None Permanent On On for 2 sec Pulsing Send Run Scene Start of Entry Delay Chime Kissoff Bypass System Low Battery Editing or Deleting Rules Programming a Scheduled Function SchedulesNone Deleting a Scheduled Function Editing a Scheduled FunctionProgramming a Scene ScenesLocks Editing/Deleting a Scene Running a Scene Programming a Reminder RemindersPlay Deleting a Reminder Editing a ReminderView/Join Available WiFi Networks WiFi ConfigurationManually Configure Access Point Viewing or Deleting Enrolled Keypads Enrolling/Syncing Auxiliary KeypadsUsing the Speaker Phone Feature Speaker Phone FeatureAnswering a Call Placing a CallUsing Remote Phone Control Feature Remote Phone Control FeatureRemote Phone Control Commands Remote Services Activating the Slide Show Slide ShowSlide Internal Case of Carbon Monoxide Alarm FIRE/CO Alarm System If InstalledSilencing a Fire/Carbon Monoxide Alarm General InformationFIRE/CO Alarm System Emergency Evacuation Entering Test Mode Testing the System to be conducted weeklyTesting or Rebooting the System Test ModesWalk Test Exiting Test Mode Maintaining your system Cleaning the Touch screenRoutine Care Changing the Lynx Touch Series System Battery Low Battery Conditions in Wireless SensorsAdditional Announcements Summary of Audible & Visual NotificationsDisplay Definition System DisplaysLED Meanings Zone Status IconsIndustry Canada IC Regulatory Agency StatementsTELEPHONE/MODEM Interface Event of Telephone Operational Problems Owners Insurance Premium Credit Request Owners Insurance Premium Credit Request Servicing Information Limitations of this Alarm System Page Page Page Page Index Touchscreen Control TWO Year Limited Warranty Corporate Center Drive, Suite Box 9040, Melville, NY