SECURING THE PREMISES

Entry/Exit Delays

system/zone status area. The alarm will continue to sound until the system is disarmed or timeout ocurs. To stop the alarm, the system must be disarmed by selecting the “Disarm” icon OR depressing the “Off” key and then entering your security code. The message “Alarm Cancelled" is displayed, in the system bar, indicating that the alarm has been cancelled (if this feature is enabled by the installer). “Alarm” and the faulted zone continue to be displayed with their associated icons in the system/zone status area. To clear the display, select the “Disarm” icon OR depress the “Off” key and then enter your security code a second time. An exit alarm also results if an entry/exit door or interior zone is faulted within two minutes after the end of the exit delay.

Entry Delay

Entry Delays give you time to disarm the system when you re-enter through the designated entrance door. You must disarm the system before the entry delay period ends, or an alarm will occur. The control beeps during the entry delay period, reminding you to disarm the system. There are two entry delays (if programmed). The first is for your primary entrance and the second can be used for a secondary entrance, where a longer delay is required to walk to the control to disarm the system. You can also arm the system with no entry delay at all by selecting the “Delay” icon prior to arming the system. This will toggle the system to “Instant”, which can provide greater security while on the premises or while away for extended periods of time. See ARMING THE SYSTEM section for procedure. See your installer for delay times programmed for your system.

Exit Delay: None, 30, 45, 60, 90 seconds, 2 minutes

Entry Delay 1: None, 30, 45, 60, 90 seconds, 2 minutes

Entry Delay 2: None, 30, 45, 60, 90 seconds, 2 minutes

LYNX Touch SIA Exit/Entry Delay Times

Exit Delay:

Entry Delay 1:

Entry Delay 2:

45, 60, 90 seconds, 2 minutes

30, 45, 60, 90 seconds, 2, 3, 4 minutes 30, 45, 60, 90 seconds, 2, 3, 4 minutes

– 24 –

Image 24
Contents Lynx Touch Security System Page Table of Contents Summary of Audible & Visual Notifications Features System OverviewGeneral Operation ZonesFire Protection Carbon MonoxideLynx Touch SIA False Alarm Prevention Features Alarms Two-Way Voice FeatureSecurity Codes Quick View of System Functions Security FunctionsAbout the Touchscreen Control GeneralTouchscreen Control Definitions Touchscreen Controls Definitions LED MeaningsAbout the Display and Indicators Display DefinitionsSystem Overview Navigating Menus LCD DisplayNavigation Keys Lynx Touch Home ScreenMenu Screens MenusUnrestricted Menu Master MenuSecuring the Premises System StatusGeneral Information System Can Be ArmedArming in Stay Mode Arming the SystemAuto Stay Feature Arming In Away Mode Armed Away Arming the System with no delay Instant Quick ExitEntry/Exit Delays Exit DelayExit Alarms Entry Delay Disarming the system and silencing alarms Disarming the SystemWhen an Alarm Occurs Bypassing Protection Zones Bypassing Individual ZonesBypassing zones Displaying Bypassed Zones Types of Panic Alarms Panic KeysPanic Keys Key FunctionActivating a panic alarm Chime Mode Chime ModeTurning Chime mode On or Off Voice Mode Voice ModeTurning Voice mode On or Off User Access User FunctionsGeneral Information Cancel Clear Editing/Deleting a User Thomas Edit View Events Viewing System EventsAll Entering message mode Message Recording and PlaybackRecording a message Playing a messages Deleting messagesSystem Adjustments Setting the date and time Clock/CalendarSystem Programming Second Third Fourth First Programming Devices Programming Field ActionDisabled None Permanent On On for 2 sec Pulsing Send Editing or Deleting Devices Scheduling User Interface Programming a Scheduled FunctionEdit Add New Delete Editing a Scheduled Function Deleting a Scheduled FunctionReminders Programming a ReminderPlay Editing a Reminder Deleting a ReminderSpeaker Phone Feature Using the Speaker Phone FeaturePlacing a Call Answering a CallRemote Phone Control Feature Using Remote Phone Control FeatureRemote Phone Control Commands To end remote phone session Hang Up or User Code +Remote Services FIRE/CO Alarm System If Installed General Information Case of Carbon Monoxide AlarmSilencing a Fire/Carbon Monoxide Alarm GeneralFIRE/CO Alarm System Living Room BedroomEmergency Evacuation Testing the System to be conducted weekly Test ModeEntering Test Mode Testing the SystemExiting Test Mode Walk TestLow Battery Conditions in Wireless Sensors Maintaining your systemRoutine Care Changing the Lynx Touch Series System Battery Summary of Audible & Visual Notifications Sound Cause AnnouncementSystem Displays Display DefinitionAlarm Trouble red Fault Yellow Bypass Ready LED Meanings Zone Status IconsRegulatory Agency Statements Industry Canada ICTELEPHONE/MODEM Interface Event of Telephone Operational Problems Owners Insurance Premium Credit Request Owners Insurance Premium Credit Request Servicing Information Limitations of this Alarm System Index Personal Emergency/Aux. Alarm TWO Year Limited Warranty Corporate Center Drive, Suite Box 9040, Melville, NY