SYSTEM FUNCTIONS
Testing the System (to be conducted weekly)
Ready To Arm
Version Number: CA01.00EXX
CRC Number: 0X877D
RF Version Number: 0.44
Walk Test | Dialer Test |
Back
4.Select the “Walk Test” or “Dialer Test” icon. If Walk Test is selected proceed to Step 5. If Dialer Test is selected proceed to Step 6
5.“Walk Test…” is displayed on the system status bar. Fault each zone as described below.
6.If the dialer test is unsuccessful the system will display a Reporter Failure message. Contact your security service provider.
Walk Test
FAULT ZONES. Open each protected door and window in turn and listen for three beeps from the control, followed by the zone’s Voice Descriptor, if it is programmed. Identification of each faulted protection point should appear on the display. The display will clear when the door or window is closed.
Walk in front of any interior motion detectors (if used) and listen for three beeps and/or voice descriptors, if programmed. The identification of the detector should appear on the display when it is activated, and its voice descriptor will be announced (if programmed). The display will clear when no motion is detected. Note that if wireless motion detectors are used, in order to conserve battery life, there is a
To test all smoke detectors, follow the manufacturer's instructions. The identification of each detector should appear on the display when each is activated.
If a problem is experienced with any protection point (no confirming sounds, no display), notify your service company.
When all protection points have been checked and are intact (closed), there should be no zone identification numbers displayed on the touchscreen.
Exiting Test Mode
When testing is completed, exit the Walk Test or Dialer Test mode by entering an Off sequence.
NOTE: If the Walk Test mode is inadvertently left active, it automatically turns off after 4 hours. The Dialer Test mode will remain active until exited via an Off sequence.
LYNX Touch SIA Exit/Entry Delay Times
The LYNX Touch SIA will send an event code to the Central Station after entering and after exiting from Test mode.
– 64 –