Recommended grounding method

For your personal safety, this appliance must be grounded. This air conditioner is equipped with a power supply cord with a 3-prong grounding plug. To minimize possible electrical shock hazard, the cord must be plugged into a mating 3-prong grounding-type wall receptacle, grounded in accordance with all local codes and ordinances. If a mating 3-prong grounding- type wall receptacle is not available, it is the consumer’s responsibility to have a properly grounded, 3-prong wall receptacle installed by a licensed installer.

It is the customer’s responsibility:

To contact a qualified electrical installer.

To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 — latest edition,* and all local codes and ordinances.

Copies of the standards listed may be obtained from:

*National Fire Protection Association Batterymarch Park

Quincy, Massachusetts 02269

Specific electrical requirements are listed in the chart. Follow the requirements for the type of plug on the power supply cord.

Método recomendado para la puesta a tierra

Para su seguridad personal, este aparato debe ser puesto a tierra. Este acondicionador de aire está equipado con un cordón eléctrico provisto de una enchufe con clavija tripolar de conexión a tierra. Para reducir a un mínimo el riesgo posible de un choque eléctrico, el cordón debe enchufarse en un tomacorriente mural para clavija con 3 terminales puesto a tierra de acuerdo con todos los códigos y reglamentos locales. Si no se dispone de un tomacorriente para clavija tripolar, es responsabilidad y obligación personal del cliente hacer instalar un tomacorriente para clavija con tres terminales debidamente puesto a tierra por un electricista calificado.

Es responsabilidad del cliente:

Llamar a un instalador eléctrico calificado.

Asegurarse de que la instalación eléctrica es adecuada y de acuerdo con el Código Nacional de Energía, ANSI/NFPA 70, última edición*, y todos los códigos y reglamentos locales.

Pueden obtenerse copias de las normas señaladas del:

*National Fire Protection Association Batterymarch Park

Quincy, Massachusetts 02269

Los requerimientos eléctricos específicos se indican en la tabla. Siga los requerimientos para el tipo de enchufe en el cordón de alimentación eléctrica.

Méthode de liaison à la terre recommandée

Pour la sécurité personnelle des utilisateurs, il faut que cet appareil soit relié à la terre. Cet appareil est alimenté par un cordon électrique comportant une fiche de branchement à 3 broches, pour liaison à la terre. Pour minimiser le risque de choc électrique, brancher le cordon d’alimentation sur une prise de courant murale compatible à 3 alvéoles, reliée à la terre conformément aux prescriptions de tous les codes et règlements locaux en vigueur. Si une prise de courant compatible avec la fiche de branchement n’est pas disponible, c’est au client qu’incombe l’obligation de faire installer une prise de courant murale à 3 alvéoles convenablement reliée à la terre, par un électricien qualifié.

C’est au client qu’incombe la responsabilité de

Contacter un électricien qualifié.

Veiller à ce que l’installation électrique soit réalisée adéquatement et en conformité avec les prescriptions du Code national des installations électriques, ANSI/NFPA 70 (dernière édition*), et de tous les codes et règlements locaux en vigueur.

On peut obtenir un exemplaire des normes mentionnées aux adresses suivantes :

*National Fire Protection Association Batterymarch Park

Quincy, Massachusetts 02269

Le tableau ci-dessous indique les caractéristiques électriques spécifiques à respecter. Respecter les exigences indiquées pour le type de fiche de branchement du cordon d’alimentation.

Power supply cord plug receptacle

 

 

 

 

 

 

Receptáculo para la clavija del cordón

Wiring requirements

Requerimientos de cableado

Spécifications de câblage

eléctrico

 

 

 

Fiche de branchement et prise de courant

 

 

 

 

 

 

 

 

• 115 volt (103.5 min. - 126.5 max.)

• 115 voltios (103.5 mín. - 126.5 máx.)

• 115 V (103,5 min.-126,5 max.)

 

0-12 amperes

0-12 amperes

0-12 A

 

15-amp time-delay fuse or circuit breaker

• fusible de retardo o disyuntor de 15 amperes

• Disjoncteur ou fusible temporisé, 15 A

 

• 14 gauge copper wiring

• cables de cobre calibre 14

• Câblage de calibre 14 (cuivre)

 

 

 

 

1/4 po

• 230 volt (207 min. - 253 max.) or

• 230 voltios (207 mín. - 253 máx.) o

• 230 V (207 min.-253 max.) ou

(0,6 cm)

• 230/208 volt (197.6 min. - 253 max.)

• 230/208 voltios (197.6 mín. - 253 máx.)

• 230/208 V (197,6 min.-253 max.)

 

 

0-12 amperes

0-12 amperes

0-12 A

 

15-amp time-delay fuse or circuit breaker

• fusible de retardo o disyuntor de 15 amperes

• Disjoncteur ou fusible temporisé, 15 A

 

• 14 gauge copper wiring

• cables de cobre calibre 14

• Câblage de calibre 14 (cuivre)

 

 

 

 

 

• 230 volt (207 min. - 253 max.) or

• 230 voltios (207 mín. - 253 máx.) o

• 230 V (207 min.-253 max.) ou

 

• 230/208 volt (197.6 min. - 253 max.)

• 230/208 voltios (197.6 mín. - 253 máx.)

• 230/208 V (197,6 min.-253 max.)

 

0-16 amperes

0-16 amperes

 

0-16 A

 

20-amp time-delay fuse or double-pole

• fusible de retardo o disyuntor bipolar de 20

 

• Disjoncteur ou fusible temporisé, 20 A

 

circuit breaker

amperes

 

• Câblage de calibre 12 (cuivre)

 

• 12 gauge copper wiring

• cables de cobre calibre 12

 

 

 

 

 

 

1/2 po

• 230 volt (207 min. - 253 max.) or

• 230 voltios (207 mín. - 253 máx.) o

• 230 V (207 min.-253 max.) ou

(1,3 cm)

• 230/208 volt (197.6 min. - 253 max.)

• 230/208 voltios (197.6 mín. - 253 máx.)

• 230/208 V (197,6 min.-253 max.)

 

0-24 amperes

0-24 amperes

0-24 A

 

30-amp time-delay fuse or circuit breaker

• fusible de retardo o disyuntor de 30 amperes

• Disjoncteur ou fusible temporisé, 30 A

 

• 10 gauge copper wiring

• cables de cobre calibre 10

• Câblage de calibre 10 (cuivre)

 

 

 

 

4

Image 25
Contents Use and Care Guide Manual de Uso y Cuidado ES a Note To You EN ContentsES Contenido Una Nota paraHelp us help you EN Air Conditioner SafetyAyúdenos a ayudarlo ES Seguridad del Acondicionador de AireEN Operating Your Air Conditioner Temperature Selection Press to raise the temperatureStarting your air conditioner If you want to change the previous settings To operate air conditioner with remote controlIf you want to keep the previous settings To raise the temperature, pressSaving energy Changing air directionNormal operating sounds Cómo poner en marcha su acondicionador de aire ES Cómo Usar Su Acondicionador de AireSi desea cambiar los ajustes anteriores El Timer Temporizador puede programarseSi desea mantener los ajustes anteriores Ahorro de energía Cómo cambiar la dirección del aireRuidos normales de operación Para programar el Temporizador para unCleaning the front panel Cleaning the air filterRepairing paint damage EN Caring for Your Air ConditionerLimpieza del filtro de aire ES Cómo Cuidar Su Acondicionador de AireLimpieza del panel delantero Reparación de la pintura dañadaFailure to do so can result in death or electrical shock EN Performing Annual MaintenanceES Mantenimiento Anual Air conditioner will not operate EN TroubleshootingAir conditioner blows fuses or trips circuit breakers Air conditioner seems to run too muchSaver Water drips from cabinet into your houseSu acondicionador de aire no funciona ES Diagnóstico de ProblemasEl aire acondicionado parece que funciona excesivamente Verifique si SoluciónTurbo Se filtra agua del gabinete a su casaES Cómo Ordenar Accesorios EN Ordering AccessoriesIf you need assistance or service EN Requesting Assistance or ServiceIf you need replacement parts For further assistanceSi necesita ayuda o servicio técnico ES Cómo Solicitar Ayuda o Servicio TécnicoSi necesita refacciones Para asistencia adicionalImportante Installation InstructionsImportant Observe all governing codes and ordinances Through-the-wall InstallationDo not block louvers in air conditioner cabinet Electric drill Nut driver Or smallerFlat washers Window lock Bracket Filler board Vertical SupportsNuts AnglesTo contact a qualified electrical installer Power supply cord plug receptacleIt is the customer’s responsibility Disjoncteur ou fusible temporisé, 15 aPlace on cardboard Front and rear coilsGround screw Is not packing materialRun to the outside ScrewsCabinet to provide the proper tilt Do Not tighten bolts at this time When using a wood, metal or plastic molding Wall room air conditioner installationsFor slide-out chassis model only Modèle à châssis coulissant seulementInsérer la coupelle de drainage N If needed, install molding around room side of cabinetAutorisé Cabinet

ACQ152XK0 specifications

The Whirlpool ACQ152XK0 is a sophisticated window air conditioning unit that effectively balances performance and energy efficiency. This model is designed to provide optimal comfort while being mindful of energy consumption, making it a popular choice for those looking to cool their personal living spaces without incurring high utility bills.

One of the standout features of the ACQ152XK0 is its robust cooling capabilities. With a cooling capacity of 15,000 BTUs, it can efficiently cool medium to large rooms up to 850 square feet, making it an excellent option for living rooms, bedrooms, and dining areas. The unit operates with multiple cooling and fan speeds, allowing users to customize their comfort settings based on their preferences and the external temperature.

Energy efficiency is a vital characteristic of the Whirlpool ACQ152XK0. It comes equipped with a high Energy Efficiency Ratio (EER), which translates to lower energy consumption without sacrificing performance. Users can take advantage of its Energy Saver mode, which enhances energy savings by automatically turning the unit off every time the desired temperature is reached and turning on again when needed. This feature not only helps lower energy bills but also contributes to a more sustainable lifestyle.

Another key technology integrated into the ACQ152XK0 is its intuitive electronic controls with a digital display. This feature allows for easy temperature adjustments and settings selection. Additionally, the model includes a convenient remote control, giving users the ability to manage their cooling preferences from anywhere in the room.

The ACQ152XK0 also incorporates a programmable timer, enabling users to set the unit to turn on or off at specific times. This feature is particularly beneficial for those with busy lifestyles, as it ensures that the space is comfortably cool when they return home.

Maintenance is made straightforward with the washable and reusable air filter, which helps to capture dust and allergens, promoting cleaner air circulation. Regular maintenance of the filter is essential to ensure efficient operation and prolong the unit's lifespan.

In summary, the Whirlpool ACQ152XK0 combines strong cooling power, energy efficiency, and user-friendly features in a sleek design. Its various technologies and characteristics make it an excellent choice for anyone seeking a reliable window air conditioning solution tailored to their comfort needs.