Bacharach 2772-0803 manual Common Parts, Options and Supplies, Service Centers, Pennsylvania

Page 44

REMOTE INTELLIGENT SENSOR - AREA MONITOR

5.4COMMON PARTS

CAT. #

DESCRIPTION

2701-1072

Polycarbonate Window **

 

 

2701-1638

Door Keypad ** order these tw

 

items together. Not supplied

 

separately

2701-1089

Trumpet Cable Gland PG-9

 

 

2701-1489

Polyglass Enclosure Assy.

 

(Low Flow instruments)

2701-1716

Polyglass Enclosure Assy.

 

(High Flow instruments ONLY)

2701-0695

Optics PCB Assembly

2701-1760

Baseboard PCB Assembly

2701-2246

Gate Mechanism Spring

2701-2256

Clutch Assy. (spring type)

 

 

2701-0101

Motor/Gearbox (Drives stepping

 

cam and take-up spool etc.)

5.5OPTIONS AND SUPPLIES

CAT. #

DESCRIPTION

2772-0251

Serial Printer Interface PCB

 

 

2772-2079

Portable Prnter 110/120 VAC

2772-2078

Portable Printer 220 VAC

2772-2077

Portable Printer 240 VAC

2772-2083

Portable Printer Cable

2701-1347

Replacement Printer Ribbon

2701-1387

Replacement Printer Paper Roll

2772-2081

Alarm Module

2701-1761

Alarm Relay PCB

2701-2149

Test Card

2701-2505

Magnet (Used with Test Card)

 

 

5.6SERVICE CENTERS

Pennsylvania

Scott Instruments

251 Welsh Pool Road Exton, PA 19341 Phone: 610-363-5450 or

1-800-634-4046

Fax: 484-875-1610

Bacharach

621 Hunt Valley Circle New Kensington, PA 15068 Phone: 724-334-5051 Fax: 724-334-5723

E-mail: help@bacharach-inc.com

Page 5-2

Instruction 2772-0803

Image 44
Contents Instruction Remote Intelligent Sensor Area Monitor Declaration of Conformity Contents Contents Verifying That a GAS Alarm WAS Caused by GAS Cleaning the Sampling Input and Optics BlockPreparation Removal of the Mechanical Chassis Replacing the Mechanical ChassisA1.1 Adjusting Light Levels on Phase 1 RIS Units RIS TEST/FAULT Parameter LOG SheetMonitored Concentration Levels High Supplement aContinuous Diagnostics & System Test Mode Battery BackupUser Selectable Alarm SET Points Optional FeaturesPower Input Requirements AccuracyPhysical OutputsInternal BACK-UP Battery DisplayKeyboard EnvironmentalTable #1 RIS Catalog Numbers & Data System Description Basic PrinciplesDoor Open and Cover Removed from Back of Door Remote Intelligent Sensor Area Monitor Remote Intelligent Sensor Area Monitor Battery Connection Mechanical InstallationElectrical Installation UnpackingSystem Power Supply Consideration & Selection SpecificationSample Lines RIS Type1 Volt Conversion System CheckTools & Materials Required Tape Cassette LoadingCheck and Adjust System For detailed instructions on adjustment Interruption of Test Mode Cycle. IfOption PCB Installation Without Terminal USESilkscreen Idents NAL Phase 2 Base Board Terminal Strips Remote Intelligent Sensor Area Monitor Remote Intelligent Sensor Area Monitor Remote Intelligent Sensor Area Monitor Complete Sampling Sequence Twin Track Tape SAMPLING. AtCHANGE-OVER from Density to Time Mode Density & Time Operating ModesMinimum Sample Time Tape Cassette LifeSystem Alarms ConstantFlashing OpticsDiagnostics Test ModeUsing the Keyboard Optional FeaturesPrinter Operation & USE Optional Feature Installing Test CardSwitch # 2 is not used and is left ‘ON SW1 TotalWhite RED Prdy Black Pprs BaudOFF Non-Bacharach Printer Interface Data Busy GroundMaintenance General Verifying That a GAS Alarm WAS Caused by GASAdjusting Light Levels Clearing a Spurious AlarmAdjusting the Door Switch Checking and Adjusting System Flow RateDisabling the ‘DOOR OPEN’ Alarm Cleaning the Sampling Input and Optics Block Measuring Pump CurrentCleaning Optics block Stepping Clamp Vertical Changing a PumpExterior Cleaning KEY Parameter ChecksInput Path Cleaning Troubleshooting GeneralMechanical Tightness Pump CheckLight Faults Door FaultExcessive Tape USE Tape BreakageRecommended Spares System Power SuppliesModel Dependent Parts Service Centers Common PartsOptions and Supplies Pennsylvania200 to HoldRemote Intelligent Sensor Area Monitor Instruction S-A3 S-A4 Instruction